• Title/Summary/Keyword: Water supply and wastewater

Search Result 312, Processing Time 0.024 seconds

The development of the water supply system in North Korea (북한 상수도의 발전과정)

  • Kim, Seung-Hyun;Shin, Jong-Dae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.143-152
    • /
    • 2021
  • It is investigated in this study how the water supply system has been developed in North Korea. Articles published in the Rodong Newspaper (North Korea official newspaper) were mainly reviewed for this purpose. It was found in this study that the development of the water supply system in the North Korea was affected by their socioeconomic situations. Their water supply development was categorized into six groups in this study since the first water supply system built in Pyongyang (1910); Occupation period (1910~1945); Introduction period (1946~1950); Restoration period (1951~1960); Advancement period (1961~1970); New village period (1971~1974); Depression period (1974~).

Application of ANFIS for Prediction of Daily Water Supply (상수도 1일 급수량 예측을 위한 ANFIS적용)

  • Rhee, Kyoung-Hoon;Kang, Il-Hwan;Moon, Byoung-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.281-290
    • /
    • 2000
  • This study investigates the prediction of daily water supply, which is a necessary for the efficient management of water distribution system. ANFIS, namely artificial intelligence, is a neural network into which fuzzy information is inputted and then processed. In this study, daily water supply was predicted through an application of network-based fuzzy inference system(ANFIS) for daily water supply prediction. This study was investigated methods for predicting water supply based on data about the amount of water which supplied in Kwangju city. For variables choice, four analyses of input data were conducted: correlation analysis, autocorrelation analysis, partial autocorrelation analysis, and cross-correlation analysis. Input variables were (a) the amount of water supply, (b) the mean temperature, and (c) the population of the area supplied with water. Variables were combined in an integrated model. Data of the amount of daily water supply only was modelled and its validity was verified in the case that the meteorological office of weather forecast is not always reliable. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 18.46% and the average error was lower than 2.36%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

  • PDF

Formation and Treatment Methods of N-Nitrosodimethylamine (NDMA) in Water and Wastewater (상하수에서 N-Nitrosodimethylamine (NDMA) 발생 및 처리법 비교 분석)

  • Kim, Jongo;Lee, Woo-Bum;Park, Soo-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.95-101
    • /
    • 2014
  • Overall studies for the N-nitrosodimethylamine (NDMA) formation and treatment methods were conducted. In this study, occurrence in several countries and emerging treatment technologies of NDMA were generally reviewed. The NDMA formation was dependent on pH, contact time, and molar ratio (monochloramine/dimethylamine). The formation was rapidly increased when the molar ratio was greater than 1. It was likely that monochloramine could be related to stimulate NDMA formation. NDMA concentrations in water supply and wastewater plants after disinfection were approximately 10 ng/L and 100 ng/L, respectively. UV oxidation and adsorption processes are regarded as effective technologies for the NDMA removal. It is suggested that the UV oxidation with proper lamps is applied in water supply system.

The North Korea water supply system investigated using laws and regulations (법령으로 살펴본 북한의 상수도 체계)

  • Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.209-218
    • /
    • 2022
  • This study has been conducted to investigate the North Korea water supply system. For this purpose, laws and regulations concerning the North Korea water utilities were analyzed. According to this study, the water supply system of North Korea is similar to that of South Korea. The major difference between these two systems lies in the national water supplier: South Korea has the national water supplier as well as the municipal suppliers, while there is no national water supplier in North Korea. It is noted that the North Korean water utilities depend on outside suppliers for resources necessary for water production such as electricity, chemicals, spare parts, etc. This could damage the North Korean water utilities. If required resources were not delivered properly (deficient quantity and/or at delayed timing), the water suppliers would encounter difficulties in water production.

Establishment of Life Cycle Management(LCM) System for Water Supply and Sewerage Systems (상하수도시설에 대한 전과정관리(LCM)시스템 구축방안 연구)

  • Park, Ji-Hyoung;Hwang, Young-Woo;Kim, Young-Woon;Park, Kwang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.303-312
    • /
    • 2012
  • Water supply and sewerage systems are the large-scale urban infrastructure ejecting large amount of environmental load over the life-cycle. Therefore, it is important not only to optimize in the aspect of economical superiority and process efficiency but also to consider earth scale environmental impact. This study aimed to suggest the establishment of life cycle management(LCM) system as an integrated management solution in urban water supply and sewerage systems. As a result, the methodology for LCM system consisting of life cycle assessment(LCA), life cycle cost(LCC), life cycle $CO_{2}(LCCO_{2})$ and life cycle energy(LCE) was developed. Also, several case studies using the latest statistics data of water supply and sewerage systems were carried out to investigate the field applicability of LCM.

Evaluation for conjunctive operation of multi-regional water supply system through risk analysis (위기대응 취약성 분석을 통한 광역상수도 연계운영 평가)

  • Hwang, Jinsoo;Choi, Taeho;Hong, Gonghyun;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.269-279
    • /
    • 2019
  • This study would present a risk analysis method to evaluate stable tap water supply in a multi-regional water supply system and propose a measure for the evaluation of the effect of the conjunctive operation of the multi-regional water supply system using this. Judging from the vulnerability for the crisis response of the entire N. multi-regional water supply system, as compared to the result of Scenario 1 in which no conjunctive pipes were operated, it was found that in Scenario 2, in which conjunctive pipes were partially operated, the vulnerability of crisis response decreased by about 30.6%, and as compared to Scenario 3, the vulnerability of crisis response decreased by 86.2%. In setting a plan for stable tap water supply in N multi-regional water supply system, using the estimated value and the method for the evaluation of the vulnerability of crisis response by pipe, by interval and by line, it is judged that this can be utilized as a basis for the judgment of the evaluation of the operation or the additional installation of conjunctive pipes.

동남아상수도협회 창립총회 회원국 보고서

  • Korea Water and Wastewater Works Association
    • 수도
    • /
    • s.13
    • /
    • pp.11-16
    • /
    • 1978
  • 78년 11월 27일 태국 방콕에서 창립총회를 가진 동아상수도협회 (The Eastern Asia Water Supply Association) 총회에 보고된 회원국 상수도현황보고를 동 회의에 참석하였던 본회 김원만 편찬위원회의 제공으로 앞으로 3회에 걸쳐 번역 게재 한다.

  • PDF

동남아상수도협회 창립총회 회원국 보고서

  • Korea Water and Wastewater Works Association
    • 수도
    • /
    • s.14
    • /
    • pp.44-55
    • /
    • 1978
  • 78년 11월 27일 태국 방콕에서 창립총회를 가진 동아상수도협회 (The Eastern Asia Water Supply Association) 총회에 보고된 회원국 상수도현황보고를 동 회의에 참석하였던 본회 김원만 편찬위원회의 제공으로 앞으로 3회에 걸쳐 번역 게재 한다.

  • PDF

Strategy for efficient operation on the backwash waste treatment in membrane filtration water treatment plant (막여과 정수장 배출수처리시설의 효율적인 운영방안)

  • Jung, Wonchae;Yu, Youngbeom;Lee, Sunju;Moon, Yongtaik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.479-489
    • /
    • 2014
  • Membrane backwashing waste shows seasonally different characteristics and it has bad settleability differently from general backwashing waste in water treatment plant. When chemicals was injected to membrane backwashing waste, the settleability was better than chemicals was not injected. However, when settled lower sludge was not discharged, flowing sludge continuously was concentrated over a certain surface and floatation penomena occurred according to flowing velocity. When the lower sludge was discharged continuously in the thickener to prevent floatation penomena of turbidity materials, the depth of sludge surface was the least and the settleability increased.

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.