• Title/Summary/Keyword: Water supply & sewage system

Search Result 61, Processing Time 0.025 seconds

Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics (시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구)

  • 전유신;문태훈
    • Proceedings of the Korean System Dynamics Society
    • /
    • 2003.08a
    • /
    • pp.1-24
    • /
    • 2003
  • The purpose of this paper was developing a development density control model for urban growth management, using system dynamics modeling. The density control model was developed to see how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. Suggesting adequate level of development density control using the model was another purpose of this paper. The model was applied to An'yang city to estimate the maximum number of population, industry structures, houses, and cars that can be adequately sustained with the current An'yang city's infrastructur capacity. The computer simulation results shows that the city is overpopulated by some 90,000 people. To reduce the population to the adequate level that the current urban infrastructure can sustain, the current city regulation on floor area ratio are needed to be strengthened at least 20 to 35%.

  • PDF

Development and Performance Evaluation of Electrodewatering System for Sewage Sludge Recycling

  • Lee, Jae-Keun;Lee, Jung-Eun;Shin, Hee-Soo;Park, Chan-Jung;Lee, Chang-Gun;Kim, Young-Hwan;Kim, Man-Jong
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.443-447
    • /
    • 2001
  • A laboratory-scale electrodewatering system for enhancing conventional filter pressure dewatering by an electric field has been developed to decrease the water content of sludge generated in the wastewater treatment. It consists of a piston-typed filter press, a power supply and data acquisition system. The offset of electrodewatering is investigated as a function of applied pressure, applied voltage, sludge type and filtration time. Also the optimal conditions for maximizing the dewatering efficiency in the eletrodewatering system are investigated. Electric field strength and mechanical pressure are in the range of from 0 to 120 V/cm and from 98.1 to 392.4 kPa. The dewatering rates increased with increasing electric strength. These experiments produced a final sludge cake with water content of 60 wt% using electrodewatering technology, compared with a 80 wt% using pressure filtration alone. The conventional filtration system using the electrodewatering shows the potential to be effective method for improving dewatering Sludge.

  • PDF

Assessment of Water Quality Based on Ecological Factors in Anyang River (안양천에서의 생태학적 수질오염도 평가)

  • Lee, Yang-Kyoo;Cho, Won Chul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.3
    • /
    • pp.39-50
    • /
    • 2006
  • In this study, the water quality investigated during 2002s to 2004s for Anyang river and its affluent that was based on biological and chemical methods as well as ecological index of each streams. The improving of water quality and the multiplicity of specious in the most streams except for Anyang, which was due to the improving of water quality and water resource. The seasonal dry states are completely disappeared, but water quality of Anyang main stream was classified as fifth grades water with BIP 8.51~10.00 and BOD 8.16~14.4mg/l in Anyang stream overall. And alpha-mesosaprobic in upper, mid parts and polysaprobic in down parts of Anyang main stream are appeared according to Saprobien system, respectively. The water supply of treated sewage is appeared that upgrading effects of water quality in Anyang main stream and affluents of Anyang city area, but the practical effects of "Saving Anyang River" could not gained because the water quality of other branches in upstream parts than upstream measuring point of Anyang main stream, Wanggok stream Sanbon stream in Gunpo and Eeiwang cities, was not improved.

Classification and Installation Cases of Small Hydraulic Turbine (소수력용 수차의 종류 및 설치 예)

  • Choi, Young-Do;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.503-506
    • /
    • 2006
  • Recently, small hydropower attracts attention because of its clean renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of small hydropower and it is necessary to study for the effect ive turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the small hydropower turbine. Therefore, this study is trying not only, to classify the type of current operating turbines installed in the domestic power plants and turbines supplied in Japan by Japanese manufacturer but also, to examine the practical turbine type and installation site to extract the small hydropower energy effectively.

  • PDF

Development of Biological Filtration Process for Effective Nitrogen Removal and its Control strategies in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거를 위한 운전제어법 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.230-237
    • /
    • 2006
  • The operational parameters and control strategies of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. Methanol addition was controlled based on the COD/N ratio or McCarty's equation. Constant COD/N ratio control results in excess addition under large diurnal fluctuation of $NOx^--N$, and McCarty's equation can be used to add appropriate amount of methanol. Control of methanol addition by on-line nitrate measurement, control of aeration by on-line DO measurement, and control of backwashing by head loss measurement are successfully operated. These results proved that this process prove the easy-maintenance and cost-effectively treatment is attainable.

Application of PCSWMM for the Analysis of Water Quantity and Quality Considering CSOs (CSOs를 고려한 도시유역의 수량 및 수질 분석을 위한 PCSWMM 모형의 적용)

  • Hong, Won-Pyo;Chung, Eun-Sung;Lee, Joon-Seok;Kim, Kyung-Tae;Lee, Kil Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.26-36
    • /
    • 2009
  • Combined sewer system (CSS) has been built in the most urban areas across the nation. During dry weather conditions, CSS works fine. But during heavy rain storms, combined sewage frequently overflows into the stream. This study simulated the hydrologic cycle and pollutant loads (BOD, SS, TN and TP) in the Mokgamcheon watershed considering combined sewer overflows (CSOs). PC storm water management model (PCSWMM) was used for continuous simulation and CSOs are considered using the flow divider. Sensitivity analysis, calibration and verification for water quantity and quality are carried out. To verify CSOs, field measurements of CSOs are compared with simulated results. As a result, 41.3% of precipitation flows into the stream directly and 1.1% of water supply flows into stream as CSOs. 6.5% of BOD total loads, 12.0% of SS, 13.6% of TP, and 29.2% of TN are from CSOs. This result will be effective to the integrated watershed management for sustainability.

Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Development and Assessment of Specific and High Sensitivity Reverse Transcription Nested Polymerase Chain Reaction Method for the Detection of Aichivirus A Monitoring in Groundwater (지하수 중 Aichivirus A 모니터링을 위한 특이적 및 고감도 이중 역전사 중합효소연쇄반응 검출법 개발 및 평가)

  • Bae, Kyung Seon;Kim, Jin-Ho;Lee, Siwon;Lee, Jin-Young;You, Kyung-A
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.3
    • /
    • pp.190-198
    • /
    • 2021
  • Human Aichivirus (Aichivirus A; AiV-A) is a positive-sense single-strand RNA non-enveloped virus that has been detected worldwide in various water environments including sewage, river, surface, and ground over the past decade. To develop a method with excellent sensitivity and specificity for AiV-A diagnosis from water environments such as groundwater, a combination capable of reverse transcription (RT)-nested polymerase chain reaction (PCR) was developed based on existing reported and newly designed primers. A selective method was applied to evaluate domestic drinking groundwater samples. Thus, a procedure was devised to select and subsequently identify RT-nested PCR primer sets that can successfully detect and identify AiV-A from groundwater samples. The findings will contribute to developing a better monitoring system to detect AiV-A contamination in water environments such as groundwater.

Indicators of Rural Regional Development Level by the City/County Type (농촌지역 발전수준 지표체계 설정과 시·군 유형별 비교)

  • Koo, Seung-Mo;Park, Yoon-Ho;Lee, Han-Sung;Choi, Se-Hyun
    • Journal of agriculture & life science
    • /
    • v.44 no.3
    • /
    • pp.99-110
    • /
    • 2010
  • This paper builds a system of indicators representing rural regional development level. Indicators were classified into two groups, that is, living environment indicator group and regional vitality indicator group. Living environment indicator group consists of four indicators including housing, road, water supply, and sewage system, while regional vitality indicator group consists of five indicators including regional economy, public finance, and demography. Real data of the year 2002 and 2006 were used to do the basic statistical analysis and estimate the suitable statistical distributions for each indicator. Data were applied for the three city/county type, general city, urban-rural combined city, and county. General cities have the strongest urbanization tendency among the three types, while counties have the weakest tendency. General cities turned out to be superior in housing condition, road density, water supply system and sewage system. Indicators of employment and local finance showed the highest levels in counties. The results of this analysis are expected to provide local governments with the appropriate reference for their rural regional development policy.

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.