• 제목/요약/키워드: Water storage

검색결과 3,747건 처리시간 0.03초

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

태양열원 난방기의 수축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of a Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.43-49
    • /
    • 2007
  • This study is conducted to improve the efficiency of a thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from the solar or the others heat sources. However, it has difficulties in storing heat with nonuniform temperature through the entire tank with respect to the vertical direction, This study is focused on the thermal stratification to improve thermal comfort for the resident in house. To enhance temperature stratification of the tank, a distributor was designed and installed in the middle of the storage tank vertically. The vertically designed distributor could supply the return water with stratified temperature in the storage tank with respect to the height. The water velocity from the distributor hole is the same with the other outlet in the distributor. However, gravity effect on the flow in the storage tank is much higher than that of the velocity effect due to that Froude Number is less than 1. During the heat charging process in the storage tank, temperature maintained with little difference with respect to the height. However the charging process takes long time to get a effective temperature for the heating or hot water supply because of all of water in the storage tank needs to be heated.

단체급식소에서 이용되는 일부 생채소의 소독방법 및 저장에 따른 품질연구 (A study for the Quality Depending on Sanitization and Storage Method of Raw Vegetables in Foodservice Operation)

  • 김혜영
    • 한국식품조리과학회지
    • /
    • 제20권6호
    • /
    • pp.684-694
    • /
    • 2004
  • The purpose of this study was to estimate the microbial and physicochemical quality of some raw vegetables and suggest safer methods of sanitization and storage for foodservice operations. Three sanitization methods were utilized during pre-preparation (tap water, chlorine water and electrolyzed water). Leek and Chicory were monitored as ingredient, with different storage temperatures $(3,\;10^{\circ}C)$ and periods (1, 2, 3, 4 and 7 days). The largest reduction in the microbial counts was shown with the electrolyzed water and for the case before immersion in chlorine water, performing a first washing was more effective in reducing the microbial counts than with no washing. The results showed that the storage temperature, pH, moisture content and microbial loads were important factors affecting the quality of vegetables.

물수지 분석을 통한 관개용 저수지의 저수율 추정 (Storage Estimation of Irrigation Reservoir by Water Balance Analysis)

  • 최진규;손재권;구자웅;김영주
    • 농촌계획
    • /
    • 제9권4호
    • /
    • pp.1-7
    • /
    • 2003
  • This study was conducted to seek the effective water management method of the irrigation reservoirs. Joongpyong reservoir was selected for the hydrologic monitoring, and investigated from May in 1999 to December in 2001. The water level and amount of outlet discharge were measured, the stage discharge equation as a rating curve was induced, and which were compared to the irrigation water requirements calculated by a daily simulation model. The water balance of Joongpyong reservoir was analyzed, mainly on the reservoir storage ratio during irrigation period. Comparing the observed storage and simulation data, the results of the simulation were well agreed with the measured data.

저수조 설치 펌프직송방식의 수도직결 증압방식 전환에 관한 에너지절약성 및 환경성 검토 (Energy-Saving and Environmental Evaluation of Water Supply System on Replacing Water Storage Installed Booster Pump System by Direct Connecting Booster Pump System)

  • 이철구
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권3호
    • /
    • pp.7-12
    • /
    • 2015
  • Currently water supply system with water storage is generally applied except for small building such as single-family houses, and water supply system on replacing water storage installed system by direct connecting system has been increasing because of sanitary and energy-saving aspects. The purpose of this study is to evaluate energy-saving and environmental efficiency of direct connecting booster pump system in comparison with the water storage installed system. The architectural condition of the evaluation subject is ten-story apartment house in which sixty households live. To calculate the power consumption of the pump, the volume of water supply was determined from existing data and other data, such as head, efficiency of the pump, was the value used for general application in design office. The power consumption of the water supply pump for one day was 8.5 kWh for direct connecting booster pump system, and 22.5 kWh for water storage installed system, and the former system showed energy savings of 62% compared to the latter system. Reduced power consumption also leads to reduction of $CO_2$ emission. According to the criteria presented in the Korea Energy Management Corporation, reducing the 2,410 kg $CO_2$ emission is possible per year.

에너지 수요처의 사용특성에 따른 태양열 급탕시스템의 효율분석 (Analysis of Efficiency of Solar Hot Water System based on Energy Demand)

  • 전용준;박경순
    • 한국태양에너지학회 논문집
    • /
    • 제37권5호
    • /
    • pp.39-47
    • /
    • 2017
  • In a hot water system using solar energy, solar heat is not simply collected by the heat collecting plate, but by heat exchange between the solar collector (flat or vacuum type) and the hot water storage tank. Therefore, the amount of collected solar energy depends on the hot water usage patterns that determine the temperature of the thermal storage tank. Also, if the temperature of the hot water stored in the storage tank exceeds the dangerous temperature during the summer, the heat must be released for safety. If the temperature of the hot water in the storage tank is low, it is necessary to heat by the auxiliary heat source. In this study, three buildings are defined as hotel, swimming pool, and school facilities. And we calculated the released heat energy, auxiliary heat source, and pure storage heat energy based on different hot water usage patterns and installation angle of the solar collectors.

전해산성수에 의한 저장기체살균이 포도의 품질특성과 부패균 생육에 미치는 영향 (Effect of Atmosphere Sterilization Using Acidic Electrolyzed Water on Storage Quality and Microbial Growth in Grapes)

  • 김성환;정헌식;이주백;강준수;정신교;최종욱
    • 한국식품영양과학회지
    • /
    • 제32권4호
    • /
    • pp.549-554
    • /
    • 2003
  • 산성 전해수를 이용하여 포도(Vitis labrusca L.)의 저장 안정성을 향상 시킬수 있는 방법을 개발하기 위하여, Campbell Early와 Sheridan 포도를 저장고 내부기체를 산성 전해수에 통과시켜 살균시키는 $0^{\circ}C$ 조건에서 저장하면서 환경기체의 살균처리가 포도의 품질특성과 미생물 생육에 미치는 영향을 조사하였다. 저장환경기체의 살균처리는 포도 품종에 따른 차이가 없이 객관적 품질특성인 가용성 고형물, 적정산도, 가용성 탄닌, 안토시아닌, 에탄올 및 아세트 알데하이드 등의 함량 변화와 관능적 품질특성인 color, aroma, texture, juiciness 및 sweetness등에 거의 영향을 미치지 않는 것으로 나타났다. 반면에 저장기체의 살균처리는 포도 품종에 약간 의존적이긴 하지만 곰팡이를 포함하는 미생물의 생육을 억제하는 효과를 보였다. 이러한 결과로 볼 때 산성 전해수에 의한 저장환경기체의 살균처리는 포도의 품질에는 해가 없으면서 부패를 억제시켜 저장 안정성을 향상시킬 수 있는 방법으로 판단된다.

Runs의 특성에 의한 지속기간별 저수부족량의 추정 (Estimation of Storage Deficit by Run's Characteritics)

  • 강관원;안경수
    • 물과 미래
    • /
    • 제19권4호
    • /
    • pp.329-338
    • /
    • 1986
  • the purpose of this study is to estimate the storage deficit by Run's Characteristics of (-)Run-length and (-)Run-sum. Runoff data are obtained from the guaging stations of Y대-Ju in Hanriver Basin, Wae-Gwan in Nak Dong River Basin and Gyo Am in Geum River Basin. In order to estimate the storage deficit, runhydrographs are established with each return period of 10, 30, ......, 200 years and regression equation is derived from relationship between (-) run-length and storage deficit. From the comparison of estimated reservoir storage with observed values., it was proved that this suggested method can be used for the estimation of the storage deficit.

  • PDF

관개용 댐의 효율적 저수관리를 통한 밭 관개 용수 확보 (Security of Upland Irrigation Water through the Effective Storage Management of Irrigation Dams)

  • 이주용;김선주;김필식
    • 한국농공학회논문집
    • /
    • 제48권2호
    • /
    • pp.13-23
    • /
    • 2006
  • In Korea, upland irrigation generally depends on the ground water or natural rainfall since irrigation water supplied from dams is mainly used for paddy irrigation, and only limited amount of irrigation water is supplied to the upland area. For the stable security of upland irrigation water, storage level of irrigation dams was simulated by the periods. A year was divided into 4 periods considering the irrigation characteristics. Through the periodical management of storage level, water utilization efficiency in irrigation dams could be enhanced and it makes available to secure extra available water from existing dams without new development of water resources. Two study areas, Seongju and Donghwa dam, were selected for this study. Runoff from the watersheds was simulated by the modified tank model and the irrigation water to upland crops was calculated by the Penman-Monteith method. The analyzed results showed that relatively sufficient extra available water could be secured for the main upland crops in Seongju area. In case of Donghwa area, water supply to non-irrigated upland was possible in normal years but extra water was necessary in drought years such as 1998 and 2001.

마늘의 저장온도에 따른 이화학적 품질변화 (Change of Physicochemical Quality According to Its Storage Temperature in Garlic (Allium sativum L.))

  • 장현세;홍경훈
    • 한국식품저장유통학회지
    • /
    • 제5권2호
    • /
    • pp.119-122
    • /
    • 1998
  • This study was conducted to blow the effect of postharvest physiological changes on garlic quality according to its ecotypes and storage temperatures. The changes of water, total soluble solids, crude stein, md total fructans were measured and the rates of respiration and sprouting were analyzed during storage at 20$^{\circ}C$ and 30$^{\circ}C$. The decrease of water content and the increase of total soluble solids were reversely appeared during garlic storage. The crude protein content was gradually increased during storage but total fructan content was decrased. The respiration late was maximized at 60days after storage and the spouting rate was gradually increased. In the aspect of ecotypic characteristics, the water content, fructan content and sprouting rate were higher in 'Namdo' cultivar than those of southern type. The high storage temperature (30$^{\circ}C$) controlled spouting and loss of fructan, and it was effective to maintain the garlic quality.

  • PDF