• Title/Summary/Keyword: Water space

Search Result 2,364, Processing Time 0.04 seconds

A Study on Facility, Program, Institution of Water-familiar Space developed on the Manned Lighthouse - Focused on the Manned Lighthouse in Young-Nam Area - (유인등대를 활용한 친수공간의 시설, 프로그램, 제도에 관한 연구 - 영남권 유인등대를 중심으로 -)

  • Ahn Woong-Hee
    • Journal of Navigation and Port Research
    • /
    • v.29 no.3 s.99
    • /
    • pp.275-282
    • /
    • 2005
  • The year 2003 is the centennial of the birth of the modem lighthouse in Korea the lighthouse was originally surrounded by a beautiful nature and it contains the romantic sensitivity which relates with the ocean. And in some case it is a environment-friendly architectural facility which uses a alternative energy like a solar cell. Now the properly developed manned lighthouse is not only functioning as a traditional aids to navigation for the vessel, but also it becomes the new facility and space for all civilians who might visit and experience. If we want to vitalize the traditional lighthouse into water-familiar space, we must reconsider the facilities, various operational programs and the institutions for future-oriented development. For this situation we intended to reveal in this study that all the issues which relate to the proper use of the manned lighthouses in the whole country, since the project of water-familiar space started by MOMAF.

Air Temperature Variation by Effect of Green Space Condition (녹지 조건에 따른 기온변화)

  • Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • In this study, we observed air temperature to make clear that land coverage condition and stand form has a certain relationship to air temperature during the night in various green space. And with revolution analysis, we interpreted relationship of air temperature distribution in the green space, The way of analysis is this land coverage rate and air temperature, of number of tree volume of tree air temperature. With this experimental result, we can propose green plan, which is taking into consideration lower effect of air temperature. In this result, lower zone is formed in forest and water area, higher zone is formed in paved surface and barren ground. but this gap is a little. arbor+subarbor area, in the point of water area surrounded stand is formed relative lower air temperature. As a result to make up efficiency lower air temperature area, it is needed to make water area which has surrounded forest, and it is needed to make stand form lower air temperature 2~3 layer forest. In order of arbor, subarbor, shrub, the lower air temperature is more effect.

A Study on the Operation Mechanism of Ongnu, the Astronomical Clock in Sejong Era

  • Kim, Sang-Hyuk;Lee, Yong-Sam;Lee, Min-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.1
    • /
    • pp.79-91
    • /
    • 2011
  • Ongnu (Jade Clepsydra; also called Heumgyeonggaknu) is a water clock was made by Jang Yeong-sil in 1438. It is not only an automatic water clock that makes the sound at every hour on the hour by striking bell, drum and gong, but also an astronomical clock that shows the sun's movement over time. Ongnu's power mechanism used is a water-hammering method applied to automatic time-signal device. The appearance of Ongnu is modeled by Gasan (pasted-paper imitation mountain) and Binpungdo (landscape of farming work scene) is drawn at the foot of the mountain. The structure of Ongnu is divided into the top of the mountain, the foot of the mountain and the flatland. There located are sun-movement device, Ongnyeo (jade female immortal; I) and Four gods (shaped of animal-like immortals) at the top of the mountain, Sasin (jack hour) and Musa (warrior) at the foot of the mountain, and Twelve gods, Ongnyeo (II) and Gwanin on the flatland. In this study, we clearly and systematically understood the time-announcing mechanism of each puppet. Also, we showed the working mechanism of the sun-movement device. Finally, we completely established the 3D model of Ongnu based on this study.

Pacific Equatorial Sea Surface Temperature Variation During the 2015 El Niño Period Observed by Advanced Very-High-Resolution Radiometer of NOAA Satellites

  • Lee, Seongsuk;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.2
    • /
    • pp.105-109
    • /
    • 2018
  • El $Ni{\tilde{n}}o$ is the largest fluctuation in the climate system, and it can lead to effects influencing humans all over the world. An El $Ni{\tilde{n}}o$ occurs when sea surface temperatures in the central and eastern tropical Pacific Ocean become substantially higher than average. We investigated the change in sea surface temperature in the Pacific Ocean during the El $Ni{\tilde{n}}o$ period of 2015 and 2016 using the advanced very-high-resolution radiometer (AVHRR) of NOAA Satellites. We calculated anomalies of the Pacific equatorial sea surface temperature for the normal period of 1981-2010 to identify the variation of the 2015 El $Ni{\tilde{n}}o$ and warm water area. Generally, the warm water in the western tropical Pacific Ocean shifts eastward along the equator toward the coast of South America during an El $Ni{\tilde{n}}o$ period. However, we identified an additional warm water region in the $Ni{\tilde{n}}o$ 1+2 and Peru coastal area. This indicates that there are other factors that increase the sea surface temperature. In the future, we will study the heat coming from the bottom of the sea to understand the origin of the heat transport of the Pacific Ocean.

Comparative Study of Maximum Temperature Condition in Green Space (녹지 조건에 따른 최고기온의 비교연구)

  • 윤용한
    • Asian Journal of Turfgrass Science
    • /
    • v.15 no.4
    • /
    • pp.181-186
    • /
    • 2001
  • In this study, we observed air temperature to make clear that land coverage condition and forest form has a certain relationship to air temperature in a day in various green space. And with revolution analysis, interpreted relationship of air temperature distribution in the green space, of land coverage rate and air temperature, of volume of tree and temperature. With this experimental result, propose green plan, taking into consideration lower effect of air temperature. In this result lower zone is formed in forest and water area, higher zone is done in paved surface and barren ground. And arbor+subarbor area, water area sur-rounded forest and small river is formed relative lower air temperature. In my opinion to promote efficiency lower air temperature area, it is need to make water area surrounded forest, to make forest form lower air temperature 2∼3 layer forest. Lower air temperature effect is in order of arbor, subarbor, shrub and is proportioned increasing of tree.

  • PDF

The Eating and Cooking Spaces of Yang-ban Houses in the Cho-sun Dynasty (조선시대 반가의 식사.취사생활과 공간사용)

  • Park, Sun-Hee
    • Journal of architectural history
    • /
    • v.1 no.2 s.2
    • /
    • pp.39-51
    • /
    • 1992
  • Eating was done on a respective one-man dining table, which reflect the esteem for the individual. The family eating place was generally An-bang of the house, The eating space of Yang-ban housing with its hierarchical, spatial method of tabling and eating around the head of the family served as a synchronically meaningful space which was to strengthen the solidarity of patriarchy beyond the mere funtioning place of eating. That meaning seems to reveal itself more conspicuously when we consider that the eating place is An-bang, the center of the main house. The basic space for cooking was Bu-oak (Chung-ji). Thre was no water-supply system or drainage in the kitchen, so all the water needed for cooking was drawn from outdoor well with a bucket. The traditional eating habits, the entertainment for the bustling guests, and the frequent sacrificial rites required many store rooms for the subasidiary food and wide space for putting food into order.

  • PDF

An analysis on the characteristics of landslides induced by heavy rainfall associated with Typhoons Herb (1996) and Troaji (2001) in Nantou on Taiwan

  • Cheng, Hsin-Hsing;Chang, Tzu-Yin;Liou, Yuei-An;Hsu, Mei-Ling
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1252-1254
    • /
    • 2003
  • Debris flows associated with landslides occur as one of the most devastating natural disasters that threat Taiwan. Typically, three essential factors are needed simultaneously to trigger debris flow, namely sufficient soils and rocks, favorable slope, and abundant water. Among the three essentials, the slope is natural and static without external forcing, while the landslide is generally induced by earthquake or rainfall events, and the water is produced by heavy rainfall events. In this study, we analyzed the landslides triggered by the typhoons Herb (1996) and typhoon Troaji (2001). It is concluded that the statistical data are useful to quantify the threshold of the potential landslide area. Then, the possibility to prevent the debris flow occurrence may be increased.

  • PDF

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Effective Functionable Water Generation Characteristics of a Slit Type Parallel Plate Electrode System in Water (수중 슬릿형 평행평판전극계에 의한 효과적인 기능수 발생특성)

  • Lee, Dae-Hee;Kim, Jin-Gyu;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.26-28
    • /
    • 2000
  • A novel oxidant generation and ion precipitation cell with slits on parallel plate electrodes system has been proposed and an effect of the number and size of slits on ion precipitation and oxidant generation characteristics. As a result, with the electrodes with 48 slits($S=200{\times}60[mm^2]$. d = 1.5, 5.0 [mm]), it is found that the oxidant contained waters of 17.0 [ppmm] and 23.5 [ppmm] in acid water were obtained with 0.1 [wt%] NaCl dissolved tap water fed. And oxidant contained waters of 0.5 [ppmm] and 1.5 [ppmm] in alkali water were obtained with 0.1 [wt%] NaCl dissolved tap water fed. And the oxidant contained waters of 7.0 [ppmm] and 11.5 [ppmm] in mixed water were obtained with tap water and 0.1 [wt%] NaCl dissolved tap water fed. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits on the electrodes of conventional cells as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode space.

  • PDF