• 제목/요약/키워드: Water solution

검색결과 6,596건 처리시간 0.036초

지하수를 이용한 양액냉각시스템 개발에 관한 기초연구 (A Fundamental Study on the Nutrient Solution Cooling System Utilizing Ground Water)

  • 남상운;손정익;김문기
    • 생물환경조절학회지
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 1993
  • Experimental and theoretical analyses were carried out to investigate the heat exchange characteristics of the nutrient solution cooling system utilizing ground water. The material of heat exchanger used in the experiment was polyethylene and the cross-flow type was adapted in which nutrient solution was mixed and ground water unmixed. For the exchanger surface area of 0.33$m^2$ and flow rates of ground water of 1-6$\ell$/min, NTU(number of transfer units) and effectiveness of experimental heat exchanger were 0.1-0.45 and 10-35%, respectively. Therefore these results showed that the hydroponic greenhouse of 1,000$m^2$(300 pyong) with the ground water of 10$m^2$/day could cover about 55-70% of maximum cooling load in summer.

  • PDF

Seawater-driven forward osmosis for direct treatment of municipal wastewater

  • Sun, Yan;Bai, Yang;Tian, Jiayu;Gao, Shanshan;Zhao, Zhiwei;Cui, Fuyi
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.449-462
    • /
    • 2017
  • Direct treatment of municipal wastewater by forward osmosis (FO) process was evaluated in terms of water flux decline, reverse salt diffusion, pollutants rejection and concentration efficiency by using synthetic seawater as the draw solution. It was found that when operating in PRO mode (active layer facing the draw solution), although the FO membrane exhibited higher osmotic water flux, more severe flux decline and reverse salt diffusion was also observed due to the more severe fouling of pollutants in the membrane support layer and accompanied fouling enhanced concentration polarization. In addition, although the water flux decline was shown to be lower for the FO mode (active layer facing the feed solution), irreversible membrane fouling was identified in both PRO and FO modes as the water flux cannot be restored to the initial value by physical flushing, highlighting the necessity of chemical cleaning in long-term operation. During the 7 cycles of filtration conducted in the experiments, the FO membrane exhibited considerably high rejection for TOC, COD, TP and $NH_4{^+}-N$ present in the wastewater. By optimizing the volume ratio of seawater draw solution/wastewater feed solution, a concentration factor of 3.1 and 3.7 was obtained for the FO and PRO modes, respectively. The results demonstrated the validity of the FO process for direct treatment of municipal wastewater by using seawater as the draw solution, while facilitating the subsequent utilization of concentrated wastewater for bioenergy production, which may have special implications for the coastline areas.

전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로- (The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II))

  • 배기서;이태상;노덕길;홍영기
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

물, Dioxane-물 및 Ethanol-물의 混合溶媒에서의 Hydrogen Cupferrate의 酸解離常數의 決定 (Determination of Dissociation Constant of Hydrogen Cupferrate in Water, Dioxane-Water, and Ethanol-Water Solution)

  • 김시중;윤창주;장인순
    • 대한화학회지
    • /
    • 제10권3호
    • /
    • pp.114-118
    • /
    • 1966
  • The glass electrode was empirically calibrated in dioxane-and ethanol-water mixed solvents, by means of which the pH-meter reading could be converted to stoichiometric hydrogen ion concentration. By the potentiometric titration method, the thermodynamic dissociation constants of hydrogen cupferrate (HCup) with variations of ionic concentration in aqueous solution were determined, and by the extrapolation of the constants the new thermodynamic $pK_a$ value, 3.980${\pm}$0.006, at zero ional concentration was obtained. The thermodynamic dissociation constants of HCup in dioxane-and ethanol-water solution were also potentiometrically determined with the changes in composition of organic solvents at 0.01 and 0.05 of the ionic strength(${mu}$) and 25 $^{\circ}C$. The empirical formula of the constants with mole fraction(n) of the organic solvent are as follow: Dioxane-water solution. $pK_a$= 12.96n + 4.10 at ${\mu}$ = 0.01, n = 0.0228∼0.171 $pK_a$= 12.05n + 4.23 at ${\mu}$ = 0.05, n= 0.0228∼0.171 Ethanol-water solution, $pK_a$= 4.0ln + 4.26 at ${\mu}$= 0.01, n= 0.0395∼0.262 $pK_a$= 3.83n + 4.34 at ${\mu}$= 0.05, n= 0.0395∼0.262

  • PDF

Effect of intermittent operation modes on performance of reverse osmosis (RO) membrane in desalination and water treatment

  • Yang, Heungsik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Seawater desalination is doubtlessly a viable option to supply fresh drinking water. Nevertheless, RO (reverse osmosis) desalination plants in specific areas may be intermittently operated to match the imbalance between water demand and supply. Although a handful of works have been done on other membrane systems, few studies have attempted to mitigate fouling in intermittent RO systems. Accordingly, the objectives of this paper were to examine the effect of the intermittent operation on RO fouling; and to compare four intermittent operation modes including feed solution recirculation, membrane storage in the feed solution, deionized water (DI) recirculation, and membrane storage in DI water. Results showed that intermittent operation reduced RO fouling under several conditions. However, the extents of fouling mitigation were different depending on the feed conditions, foulant types, and membrane lay-up methods. When the feed solution was recirculated during the lay-up, the restoration of the flux was less significant than that by the feed solution feed-up. The use of deionized water during the lay-up was effective to restore flux, especially when the feed solution contains scale-forming salts (CaSO4) and/or colloidal silica.

실파의 수경재배에 적합한 양액종류 선발 (Selection of Proper Nutrient Solution Existing for the Water Culture of Young Welsh Onion)

  • 원재희;전신재;김상수;박권우
    • 생물환경조절학회지
    • /
    • 제14권4호
    • /
    • pp.263-268
    • /
    • 2005
  • 실과용으로 적합한 양액종류를 선발하고자 수경재배용으로 선발한 '금장외대파'와 '토쿄구로파'을 공시하여 담액식으로 시험을 수행하였다. 양액종류로 기존 파용 지바농시액, 엽채소용 M식액, 파용 타케가와액, 및 싹파용 야마자키액을 이용하여 시험한 결과, 구당 생체 중 및 건물중에 있어서 두 품종 모두 야마자키액, M식액, 지바농시액, 타케가와액 순으로 양호하였다. 생체중과 건물중 증가, 그리고 양분 흡수율 및 기타 요인을 모두 고려하였을 때 실파 수경재배용으로 가장 적정한 배양액으로 싹파용 야마자키액을 선발하였다.

증산법에 의한 잣나무와 일본잎갈나무의 목부내 염료침투 (Dye Penetration into Xylem of Pinus koraiensis and Larix leptolepis by Transpiration Method)

  • 전수경
    • 한국가구학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2001
  • This study was carried out to elucidate the relationship between wood anatomy and the water flow path in P. koraiensis and L. leptolepis. through the experiment of penetration of the dye solution. The experiment was performed by permeating 1% acid, alkali and direct solution into the xylem just after being cut. The results obtained were summarized as follows : 1. In P. koraiensis and L. leptolepis, the dye solution penetrated into sapwood and annual rings adjacent to cambial zone were only dyed according to ascent of tree height. 2. The penetrability of latewood was better than that of earlywood. 3. In P. koraiensis and L. leptolepis, the main water flow path in longitudinal direction was the trachied and that in transverse direction was ray trachied and ray parenchyma. Also, the dye solution was found in resin canal. 4. P. koraiensis was more permeable than L. leptolepis. 5. Among the acid, alkali and direct dye solution, the acid dye solution was the most permeable.

  • PDF

Studies on Equilibria and Analytical Applications of Synergistic Solvent Extraction(II). Determination of Trace Lithium in Sea Water using TTA and TOPO

  • 김영상;최종문;이치우
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권9호
    • /
    • pp.855-859
    • /
    • 2000
  • An application of synergistic solvent extraction for the etermination of trace lithium in sea water has been studied by forming an adduct complex of thenoyltrifluoroacetone (TTA) and trioctylphosphine oxide (TOPO) in a solvent. The interference by major constituents in sea water was eliminated by phosphate precipitation. Ex-perimental conditions such as solution pH, concentrations of TTA and TOPO etc. were optimized in synthetic sea water with similar compositionto its natural counterpart. To eliminate the interference, 1.38g of ammoni-um dihydrogen phosphate and 2.5 mL of ammonia water were added into 100 mL of thediluted solution at $60^{\circ}C$ to form the phosphate precipitates of Ca2+ and Mg2+ ions. After the pH of this filtrate was adjusted to 8.0, 10.0 mL of m-xylene containing 0.1 M TTA and 0.05 M TOPO was added to the solution in a separatory funnel, and the solution was shaken vigorously for 20 minutes. The solvent was separated from the aqueous solution, and 20 uL of m-xylene solution was injected into a gaphite tube to measure the absorbance by GF-AAS. The detection limit was 0.42 ng/mL. Lithium was determined within the range of 146 to 221 ng/mLin Korean coast-al sea waters, and the recoveries in the spiked samples were 94 to 106%.

Technology to reduce water ingress for TBM cutterhead intervention

  • Ham, Soo-Kwon;kim, Beom-Ju;Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • 제29권3호
    • /
    • pp.321-329
    • /
    • 2022
  • Tunnel site where high water pressure is applied, such as subsea tunnel, generally selects the shield TBM (Tunnel Boring Machine) to maintain the tunnel excavation face. The shield TBM has cutters installed, and the cutters wear out during the process of excavation, so it should be checked and replaced regularly. This is called CHI (Cutterhead Intervention). The conventional CHI under high water pressure is very disadvantageous in terms of safety and economics because humans perform work in response to high water pressure and huge water inflow in the chamber. To overcome this disadvantage, this study proposes a new method to dramatically reduce water pressure and water ingress by injecting an appropriate grout solution into the front of the tunnel face through the shield TBM chamber, called New Face Grouting Method (NFGM). The tunnel model tests were performed to determine the characteristics, injection volume, and curing time of grout solution to be applied to the NFGM. Model test apparatus was composed of a pressure soil tank, a model shield TBM, a grout tank, and an air compressor to measure the amount of water inflow into the chamber. The model tests were conducted by changing the injection amount of the grout solution, the curing time after the grout injection, and the water/cement ratio of grout solution. From an economic point of view, the results showed that the injection volume of 1.0 L, curing time of 6 hours, and water/cement ratio of the grout solution between 1.5 and 2.0 are the most economical. It can be concluded that this study has presented a method to economically perform the CHI under the high water pressure.

고로 슬래그 시멘트 페이스트 내 자유염화물량과 물가용성 염화물량 평가에 관한 연구 (A Study on the Evaluation of the Water-soluble Chloride Content and Free-chloride Content in Blast Furnace Slag Cement Pastes)

  • 조영국;소승영
    • 한국건축시공학회지
    • /
    • 제4권4호
    • /
    • pp.95-101
    • /
    • 2004
  • The purpose of this paper is to compare free-chloride content with water-soluble chloride in blast furnace cement(BSC) paste. The content of free-chloride in cement paste measured by pore solution analysis and water-soluble chloride measured by ASTM. The result of this study are as follows: 1. The concentration of chloride ion in pore solution of BSC-solidified matrix is almost as low as 43-71% compared to that of OPC-solidified matrix containing the same chloride content in cement paste. 2. The binding capacity of specimens, OPC Pl-P5, are 93.5-77%, but the binding capacity of specimens, BSC Pl-P5 are 97.1-86.1%, which is to be as high as 2-9.1% compared to OPC containing the same chloride content. 3. In terms of water-soluble chloride content in BSC paste are 15-31.7 percent of chloride addition but free-chloride content in pore solution are 2.9-13.9 percent of chloride addition. The free-chloride content in pore solution is 19.3-43.8 percent lower for the water-soluble chloride content in cement paste.