• Title/Summary/Keyword: Water separator

Search Result 150, Processing Time 0.023 seconds

An Effect of Laminated Plate on the Performance of Pre-separator for Marine Oily Water Separator (선박 유수분리기 전처리 장치 성능에 미치는 적층판의 영향)

  • 이진열;한원희
    • Tribology and Lubricants
    • /
    • v.16 no.6
    • /
    • pp.440-447
    • /
    • 2000
  • It's a tendency to strengthen related international laws as the importance on marine oil pollution recently becomes the issue. According to the regulation of IMO, oil discharge from ships is allowed under 15 ppm only and oil filtering equipment is essential. However, for large ships using heavy fuel oil of over S.G 0.98 and viscosity 380 cSt and system oil, it has been in difficulty to process with existing filtering type of oily water separator. Oily water pre-separator of laminated plate type which is one of gravity type separator has very simple structure and it also makes easier to maintain and repair. In another words, it fits well to process large amount of rich oil with high specific gravity. In this paper, oily water pre-separator of laminated plate type has been studied. The function of emulsified oil and 4 different types of oil have been analyzed and each character has been investigated and proved by experiments. As the result of it, the efficiency of separating oil water has been advanced by 10% in case equipped with pre-separator. In addition, the higher temperature is and the more laminated plate has, it turns out to be getting more effect.

Three-Phase Eulerian Computational Fluid Dynamics (CFD) of Air-Water-Oil Separator with Coalescer (유적 합체기가 포함된 공기-물-기름 분리 공정에 대한 3상 Eulerian 전산유체역학)

  • Lim, Young-Il;Le, Thuy T.;Park, Chi-Kyun;Lee, Byung-Don;Kim, Byung-Gook;Lim, Dong-Ha
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.201-213
    • /
    • 2017
  • Water is removed from crude oil containing water by using oil separator. This study aims to develop a three-dimensional (3D) Eulerian computational fluid dynamics (CFD) model to predict the separation efficiency of air-water-oil separator. In the incompressible, isothermal and unsteady-state CFD model, air is defined as continuous phase, and water and oil are given as dispersed phase. The momentum equation includes the drag force, lift force and resistance force of porous media. The standard k-${\varepsilon}$ model is used for turbulence flow. The exit pressures of water and oil play an important role in determining the liquid level of the oil separator. The exit pressures were identified to be 6.3 kPa and 5.1 kPa for water and oil, respectively, to keep a liquid level of 25 cm at a normal operating condition. The time evolution of volume fractions of air, water and oil was investigated. The settling velocities of water and oil along the longitudinal separator distance were analyzed, when the oil separator reached a steady-state. The oil separation efficiency obtained from the CFD model was 99.85%, which agreed well with experimental data. The relatively simple CFD model can be used for the modification of oil separator structure and finding optimal operating conditions.

Development of a prediction model relating the two-phase pressure drop in a moisture separator using an air/water test facility

  • Kim, Kihwan;Lee, Jae bong;Kim, Woo-Shik;Choi, Hae-seob;Kim, Jong-In
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3892-3901
    • /
    • 2021
  • The pressure drop of a moisture separator in a steam generator is the important design parameter to ensure the successful performance of a nuclear power plant. The moisture separators have a wide range of operating conditions based on the arrangement of them. The prediction of the pressure drop in a moisture separator is challenging due to the complexity of the multi-dimensional two-phase vortex flow. In this study, the moisture separator test facility using the air/water two-phase flow was used to predict the pressure drop of a moisture separator in a Korean OPR-1000 reactor. The prototypical steam/water two-phase flow conditions in a steam generator were simulated as air/water two-phase flow conditions by preserving the centrifugal force and vapor quality. A series of experiments were carried out to investigate the effect of hydraulic characteristics such as the quality and liquid mass flux on the two-phase pressure drop. A new prediction model based on the scaling law was suggested and validated experimentally using the full and half scale of separators. The suggested prediction model showed good agreement with the steam/water experimental results, and it can be extended to predict the steam/water two-phase pressure drop for moisture separators.

Conceptual Design of Sandglass-like Separator for Immobilized Anionic Radionuclides Using Particle Tracking Based on Computational Fluid Dynamics

  • Park, Tae-Jin;Choi, Young-Chul;Ham, Jiwoong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.363-372
    • /
    • 2020
  • Anionic radionuclides pose one of the highest risks to the long-term safety assessments of disposal repositories. Therefore, techniques to immobilize and separate such anionic radionuclides are of crucial importance from the viewpoints of safety and waste volume reduction. The main objective of this study is to design a separator with minimum pressure disturbance, based on the concept of a conventional cyclone separator. We hypothesize that the anionic radionuclides can be immobilized onto a nanomaterial-based substrate and that the particles generated in the process can flow via water. These particles are denser than water; hence, they can be trapped within the cyclone-type separator because of its design. We conducted particle tracking analysis using computational fluid dynamics (CFD) for the conventional cyclone separator and studied the effects due to the morphology of the separator. The proposed sandglass-like design of the separator shows promising results (i.e., only one out of 10,000 particles escaped to the outlet from the separation zone). To validate the design, we manufactured a laboratory-scale prototype separator and tested it for iron particles; the efficiency was ca. 99%. Furthermore, using an additional magnetic effect with the separator, we could effectively separate particles with ~100% efficiency. The proposed sandglass-like separator can thus be used for effective separation and recovery of immobilized anionic radionuclides.

Manufacture and Efficiency Evaluation of Oil Water Separator (유수분리기의 제작과 성능 평가)

  • 유연향;장동환;오무송;이은학;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.160-164
    • /
    • 2000
  • This paper describes oil water separator using difference of electrical resistor. Oil is a non-conductive element and water is a relatively high conductive element. It is possible to detect water included in oil. Electric sensor is formed 8mm iron stick. Valve is operated With controller inputting signal of electric sensor. A experiment was done for necessary voltage in making program of controller. Oil water separator which was tested in field conditions was saved 7% of whole oil and was drained over 150% water than manual valve.

  • PDF

A Study on the Oil/Water Separation Efficiency of Laminated Plate Type Oily water Separator with Inclined Angle (경사각을 갖는 적층판식 유수분리기의 유수분리 효율에 관한 연구)

  • 한원희;김준효;최민선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.365-374
    • /
    • 2001
  • Its a tendency to strengthen related international was as the importance on marine oil pollution recently becomes the issue. According to the regulation of IMO, oil discharge from ships is allowed under 15PPM only and oil filtering equipment is essential. Oily water separator of laminated plate type which is one of gravity type separator can be use as assistant equipment for the oil filtering system to meet the present IMO standard, because it fits well to process large amount of rich oil with high specific gravity. The purpose of this paper is to investigate an efficiency of oil/water separation with the characteristics of laminated plate arrangement. The analyse of oil contents for oil-water mixture were carried out in order to find an efficiency of oil/water separation and an experimental study was simultaneously carried out to investigate internal flow characteristics of separator by visualization method and PIV(Particle Image Velocimetry) measurement at three spaces of plates for 5, 10 and 15 mm with variation of inlet flow rates of $0.25m^3$/h and $0.5m^3$/h. The experimental results showed that the space of the plates acts a significant role in the separating process.

  • PDF

2D Finite element analysis of rectangular water tank with separator wall using direct coupling

  • Mandal, Kalyan Kumar;Maity, Damodar
    • Coupled systems mechanics
    • /
    • v.4 no.4
    • /
    • pp.317-336
    • /
    • 2015
  • The present paper deals with the analysis of water tank with elastic separator wall. Both fluid and structure are discretized and modeled by eight node-elements. In the governing equations, pressure for the fluid domain and displacement for the separator wall are considered as nodal variables. A method namely, direct coupled for the analysis of water tank has been carried out in this study. In direct coupled approach, the solution of the fluid-structure system is accomplished by considering these as a single system. The hydrodynamic pressure on tank wall is presented for different lengths of tank. The results show that the magnitude of hydrodynamic pressure is quite large when the distances between the separator wall and tank wall are relatively closer and this is due to higher rotating tendency of fluid and the higher sloshed displacement at free surface.

Study on the Effect of Design Parameters of the Vane Type Inertial Separator Using Commercial CFD Code (상용 CFD 프로그램을 사용한 베인형 관성분리기의 설계인자 영향 검토)

  • Lee, Dap-Yeon;Lew, Jae-Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.470-475
    • /
    • 2017
  • Since the intake air of gas turbine engine of marine purpose contains water particles, inertial separator for separating the air and water particles are provided. Saw type and wave type separator are now used to separate inflow water particle from the gas. In this paper, the design parameters of saw type separator are studied by numerical simulations. Using the commercial CFD program, Star-CCM+, Lagrangian-Eulerian method was used to perform the analysis of two phase flow of the mist in the air. This method solves Reynolds-Averaged Navier-Stokes equations in Eulerian framework for the continuous phase, while solves equation of motion for individual particles in Lagrangian framework. Lagrangian multiphase method was applied to monitor the particles of different sizes and shapes and to verify collision between particles by chasing particles. Water particles were injected through injectors located at the inlet of the separator and escape mode was used which assumes that the particles attached on the surface of inertial separator were removed from the simulation, effectively escaping the solution domain. Through the numerical computations with the inlet condition of constant water particle size in the wetness fraction of 85%, efficiency of eliminating the water particle and the pressure drop between the inlet and outlet were examined.

A Study on the Flow Characteristics for the Plate Chamber in Type of Oily Parallel Plate Water Separator (평행판식 유수분리기에서 분리판실의 유동특성에 관한 연구)

  • Kim, J.H.;Han, W.H.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.64-72
    • /
    • 2001
  • According to the regulation of IMO, oil discharge from ships is allowed under 15ppm only and an oil filtering equipment is essential. However, for large ships using heavy fuel oil of over S.G 0.98 and viscosity 380cSt and system oil, it has been in difficulty to process with existing filtering type of oily water separator. A parallel plate type oily water separator which is one of gravity type separators can be used as an assistant equipment for the oil filtering system to meet the present IMO standard of 15 ppm, because it is an efficient method in dealing with a large amount of rich oil with high specific gravity. This work is focused on the fundamental investigation of the performance of the plate type oily water separator by visualization method and PIV(Particle Image Velocimetry) measurement to acquire multi-point velocity data simultaneously. The experimental results showed that the space of the plates acts a significant role in separating process and it was found that an important point to minimize a vortex flow is to flow a large amount of fluid in space of the plates in order to promote the efficiency of separation.

  • PDF

Evaluations of Grit Removal Efficiency of Tornado Block-Type Vortex Grit Separator (토네이도 블록형 선회류 침사제거기의 침사제거효율 평가)

  • Kim, Jong-Je;Lee, Bum-Soo;Yeom, Cheol-Min;Lim, Hee-Jae;Jung, Seok-Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.288-294
    • /
    • 2005
  • This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.