• 제목/요약/키워드: Water quality parameters

검색결과 1,072건 처리시간 0.028초

Assessment of Groundwater Quality for Irrigation and Agro-based Industrial Usage in Selected Aquifers of Bangladesh

  • Rahman, Md. Mokhlesur;Hoque, Syed Munerul;Jesmin, Sabina;Rahman, Md. Siddiqur;Kim, Jang-Eok
    • 한국환경농학회지
    • /
    • 제24권2호
    • /
    • pp.98-105
    • /
    • 2005
  • Groundwater sampled from 24 tube wells of three districts namely Sherpur, Gaibandha and Naogaon in Bangladesh was appraised for their water quality for irrigation and agro-based industrial usage. All waters under test were slightly alkaline to alkaline (pH = 7.2 to 8.4) in nature and were not problematic for crop production. As total dissolved solid (TDS), all groundwater samples were classified as fresh water (TDS<1,000 mg/L) in quality. Electrical conductivity (EC) and sodium adsorption ratio (SAR) values reflected that waters under test were under medium salinity (C2), high salinity (C3) and also low alkalinity (S1) hazard classes expressed as C2S1 and C3S1. As regards to EC and soluble sodium percentage (SSP), groundwater samples were graded as good and permissible in category based on soil properties and crop growth. All water samples were free from residual sodium carbonate (RSC) and belonged to suitable in category. Water samples were under soft moderately hard, hard and very hard classes. Manganese, bicarbonate and nitrate ions were considered as major pollutants in some water samples and might pose threat in soil ecosystem for long-term irrigation. For most of the agro-based industrial usage, Fe and Cl were considered as troublesome ions. On the basis of TDS and hardness, groundwater samples were not suitable for specific industry. Some water samples were found suitable for specific industry but none of these waters were suitable for all industries. The relationship between water quality parameters and major ions was established. The correlation between major ionic constituents like Ca, Mg, K, Na, $HCO_3$ and Cl differed significantly. Dominant synergistic relationships were observed between EC-TDS, SAR-SSP, EC-Hardness, TDS-Hardness and RSC-Hardness.

전기화학적인 방법에 의한 반응성 염료폐수의 처리 (Treatment of reactive dyes wastewater by electrochemical method)

  • 유재정;전성환;박정민;정제호;박상정;민경석
    • 한국물환경학회지
    • /
    • 제18권3호
    • /
    • pp.245-251
    • /
    • 2002
  • Reactive dyes waste water, a toxic and refractory pollutant, was treated by an electrochemical method using $Ti/IrO_2$ as anode and Stainless Steel 316 as cathode. In this technique, sodium chloride as an electrolyte was added. A number of experiments were run in a batch system. Artificial samples (reactive blue 19, red 195, yellow 145) were used. Operation parameters, such as supporting electrolyte concentration, current density, pH and sample concentration have been investigated for their influences on COD and color removal efficiencies during electrolysis. After 5 and 90 minites of eletrolysis, color was reduced by 51.5% and 98.9% respectively. Under the condition of current density $10A/dm^2$, NaCl concentration 12mg/l and pH 3, 62.9% of $COD_{Cr}$ was removed after electrolysis for 90 minites. The optimum condition of color removal and COD reduction in this work was found to be the following : pH 3, sodium chloride concentration 20g/l, current density $10A/dm^2$. As a result, we confirmed to be effective to color removal and reduction of refractory organic material.

장기유출 수문모형을 이용한 하천수질모형의 기준유량 산정 (Low Flow Estimation for River Water Quality Models using a Long-Term Runoff Hydrologic Model)

  • 김상단;이건행;김형수
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.575-583
    • /
    • 2005
  • In this study the flow curve estimation is discussed using TANK model which is one of hydrologic models. The main interest is the accuracy of TANK model parameter estimation with respect to the sampling frequency of input data. For doing this, input data with various sampling frequencies is used to estimate model parameters. As a result, in order to generate relatively accurate flow curve, it is recommendable to measure stream flow at least every 8 days.

Eco-environmental assessment in the Sembilan Archipelago, Indonesia: its relation to the abundance of humphead wrasse and coral reef fish composition

  • Amran Ronny Syam;Mujiyanto;Arip Rahman;Imam Taukhid;Masayu Rahmia Anwar Putri;Andri Warsa;Lismining Pujiyani Astuti;Sri Endah Purnamaningtyas;Didik Wahju Hendro Tjahjo;Yosmaniar;Umi Chodrijah;Dini Purbani;Adriani Sri Nastiti;Ngurah Nyoman Wiadnyana;Krismono;Sri Turni Hartati;Mahiswara;Safar Dody;Murdinah;Husnah;Ulung Jantama Wisha
    • Fisheries and Aquatic Sciences
    • /
    • 제26권12호
    • /
    • pp.738-751
    • /
    • 2023
  • The Sembilan Archipelago is famous for its great biodiversity, in which the humphead wrasse (Cheilinus undulatus) (locally named Napoleon fish) is the primary commodity (economically important), and currently, the environmental degradation occurs due to anthropogenic activities. This study aimed to examine the eco-environmental parameters and assess their influence on the abundance of humphead wrasse and other coral reef fish compositions in the Sembilan Archipelago. Direct field monitoring was performed using a visual census throughout an approximately one km transect. Coral cover data collection and assessment were also carried out. A coastal water quality index (CWQI) was used to assess the water quality status. Furthermore, statistical-based analyses [hierarchical clustering, Pearson's correlation, principal component analysis (PCA), and canonical correspondence analysis (CCA)] were performed to examine the correlation between eco-environmental parameters. The Napoleon fish was only found at stations 1 and 2, with a density of about 3.8 Ind/ha, aligning with the dominant composition of the family Serranidae (covering more than 15% of the total community) and coinciding with the higher coral mortality and lower reef fish abundance. The coral reef conditions were generally ideal for supporting marine life, with a living coral percentage of about > 50% in all stations. Based on CWQI, the study area is categorized as good and excellent water quality. Of the 60 parameter values examined, the phytoplankton abundance, Napoleon fish, and temperature are highly correlated, with a correlation coefficient value greater than 0.7, and statistically significant (F < 0.05). Although the adaptation of reef fish to water quality parameters varies greatly, the most influential parameters in shaping their composition in the study area are living corals, nitrites, ammonia, larval abundance, and temperature.

HSPEXP 모형평가지표를 이용한 HSPF 모형의 수문매개변수 보정 (Calibration of Hydrologic Parameters of HSPF Using HSPEXP Model Performance Criteria)

  • 김상민;성충현;박승우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.116-119
    • /
    • 2009
  • HSPF 모형은 수문, 유사, 영양물질, 대장균, 농약 등 다양한 성분 모의할 수 있는 준분포형의 개념적 모형으로 미국 환경청에 의해 개발되었다. 본 연구에서는 HSPF 모형의 수문 매개변수를 보정하기 위하여 HSPF 모형의 보정을 위한 전문가 시스템인 HSPEXP를 이용하였다. HSPF 모형의 수문인자의 초기치는 BASINS의 기술노트 6에 있는 가이드라인을 이용하여 추정되었다. 시험유역에 대한 초기치는 주어진 매개변수의 범위 내에서 보정되었다. 시험유역은 경기도 화성시에 있는 발안HP#6 유역의 자료를 이용하였으며 1996년부터 2007년까지의 자료가 이용되었다.

  • PDF

EPANET을 이용한 상수도 관망의 잔류염소 거동 예측 (Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET)

  • 유희종;김주원;정효준;이홍근
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.

먹는샘물과 병입수로 이용되는 천연 광천수의 국내외 관리와 연구 동향 분석 (Recent Trends of Domestic and International Management and Research of Natural Mineral Water Used for Bottled Water)

  • 고동찬;고경석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권6호
    • /
    • pp.9-27
    • /
    • 2018
  • In recent years, the sales of bottled spring water (BSW) have been drastically increasing in Korea and other countries, which accompanied great interests in conservation and reclamation of natural mineral water (NMW). In this study, management and research activities on NMW in Europe, USA, and Codex Alimentarius were reviewed. In each region, NMW is regulated with its own quality standards that differ from ordinary drinking water, and management actions are strictly implemented to protect water resources and to secure quality of NMW. Many studies on NMW were carried out for monitoring inorganic constituents including major and trace elements in national levels for bottled NMW, groundwater, and tap water in other countries. In Korea, NMW became commercialized in 1995 when BSW was legally approved as a drinking water. To further promote utilization of various types of NMW in Korea, regulations and policies for NMW need to be revised in accordance with international NMW management trends. Further, studies of NMW that compile a comprehensive set of physical and chemical parameters of NMW are also needed to properly understand occurrences, hydrogeological and geochemical processes of NMW, as well as to evaluate its potential use as a natural resource.

동계와 춘계 진해만 표층수질에 대한 통계분석 (Statistical Analysis on the Quality of Surface Water in Jinhae Bay during Winter and Spring)

  • 김동선;최현우;김경희;정진현;백승호;김영옥
    • Ocean and Polar Research
    • /
    • 제33권3호
    • /
    • pp.291-301
    • /
    • 2011
  • To investigate major factors controlling variations in water quality, principal component analysis and cluster analysis were used to analyze data sets of 12 parameters measured at 23 sampling stations of Jinhae Bay during winter and spring. Principal component analysis extracted three major factors controlling variations of water quality during winter and spring. In winter, major factors included freshwater input, polluted material input, and biological activity. Whereas in spring they were polluted material input, freshwater input, and suspended material input. The most distinct difference in the controlling factors between winter and spring was that the freshwater input was more important than the polluted material input in winter, but the polluted material input was more important than the freshwater input in spring. Cluster analysis grouped 23 sampling stations into four clusters in winter and five clusters in spring respectively. In winter, the four clusters were A (station 5), B (stations 1, 2), C (station 4), and D (the remaining stations). In spring, the five clusters included A (station 5), B (station 1), C (station 3), D (station 6), and E (the remaining stations). Intensive management of the water quality of Masan and Hangam bays could improve the water quality of Jinhae Bay since the polluted materials were mainly introduced into Jinhae Bay through Masan and Hangam bays.

건물용도에 따른 개별오수처리시설의 운영실태에 관한 연구 (A Survey on Operating State of ISWTP according to Building Use Type)

  • 권은미;김종석;정욱진
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.337-341
    • /
    • 2005
  • It is difficult to use average sewage water quality as a design parameter for the individual sewage wastewater treatment plant(ISWTP), because sewage water quality is very various according to the building use type. So, in this study, we estimated daily, seasonal and weekly trend of sewage water quality and flow rate in various kind of building to comprehend operating state of ISWTP. The sewage water quality and flow rate were higher in the business building than household building. The seasonal difference of the water quality was not detected but that of flow rate was high. The flow rate of the sewage in the business building was higher in summer than in other seasons and in weekend than in weekday. The treatment efficiency of IWSTP was about $70{\sim}80%$ with BOD, $40{\sim}50%$ with TN and TP, which was very low. The unit loads of the individual house were 36.05 gpcd with BOD, 37.91 gpcd with SS, 23.91 gpcd with T-N, and 7.90 gpcd with T-P respectively, and those values were higher than other studies. It is because, as distinct from other studies, sewage water quality was monitored at the inlet point of the IWSTP in this study. We can use this results as an one of basic parameters for the design of IWSTP.

Optimization of Process Parameters for Dry Film Thickness to Achieve Superior Water-based Coating in Automotive Industries

  • Prasad, Pranay Kant;Singh, Abhinav Kr;Singh, Sandeep;Prasad, Shailesh Kumar;Pati, Sudhanshu Shekher
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.121-129
    • /
    • 2022
  • A study on water-based epoxy coated on mild steel using the electroplating method was conducted to optimize the process parameters for dry film thickness to achieve superior paint quality at optimal cost in an automotive plant. The regression model was used to adjust various parameters such as electrode voltage, bath temperature, processing time, non-volatile matter, and surface area to optimize the dry film thickness. The average dry film thickness computed using the model was in the range of 15 - 35 ㎛. The error in the computed dry film thickness with reference to the experimentally measured dry film thickness value was - 0.5809%, which was well within the acceptable limits of all paint shop standards. Our study showed that the dry film thickness on mild steel was more sensitive to electrode voltage and bath temperature than processing time. Further, the presence of non-volatile matter was found to have the maximum impact on dry film thickness.