• Title/Summary/Keyword: Water quality analyze

Search Result 580, Processing Time 0.03 seconds

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

A Study on Improvement Measures for the Design Documents Delivery System in Public Road Construction Projects (공공 도로건설사업에서의 설계도서 납품체계 개선방안에 관한 연구)

  • Ok, Hyun;Kim, Seong-Jin;Kim, Tae-Hak;Ju, Ki-Bum
    • International Journal of Highway Engineering
    • /
    • v.20 no.2
    • /
    • pp.45-55
    • /
    • 2018
  • PURPOSES : This study aims to survey and analyze the status of the design and completion documents output delivery system in public construction projects in order to assess the problems of the Ministry of Land, Infrastructure and Transport (MOLIT)'s electronic delivery system, with a focus on roads and rivers, and to offer improvement measures. METHODS : This study first surveys and analyzes laws and existing study trends with regard to the design and completion documents output delivery system in public construction projects. It further analyzes the status of the output delivery system in public construction projects, including roads, rivers, expressways, water resources, and railroads. In addition, a comparative analysis of the current electronic delivery system of MOLIT and Korea Expressway Corporation in the road field is conducted, and the problems and improvement measures for MOLIT's electronic output delivery system are presented. This study seeks to analyze problems and prepare improvement measures with regard to road and river public construction projects, as ordered by MOLIT's five regional offices. RESULTS : This study sought to prepare the electronic output delivery system with regard to public construction projects and present the analysis of its major problems and improvement measures in four categories: "the preparation of electronic design documents output delivery system improvement measures including inspection and delivery," "preparation of guidelines, systems, etc., concerning electronic design documents," "preparation of improvement measures for the construction project management system and electronic design document support tools", and "linking of MOLIT's electronic output delivery system with relevant agencies and the expansion thereof to local governments." CONCLUSIONS : This study analyzed the current status and problems of the MOLIT's electronic output delivery system in the field of road and river construction projects, and presented corresponding improvement measures. This study is expected to address the problems of the MOLIT's electronic output delivery system, and to provide the foundation for the preparation of an efficient electronic output delivery system for design and completion documents. In addition, this study is expected to boost the quality and utilization of the electronic design documents output, and to exchange, share, and link construction information among relevant agencies so as to prepare the foundation for sharing construction information.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

Marine ecosystem risk assessment using a land-based marine closed mesocosm: Proposal of objective impact assessment tool (육상 기반 해양 폐쇄형 인공생태계를 활용한 해양생태계 위해성 평가: 객관적인 영향 평가 tool 제시)

  • Yoon, Sung-Jin
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.1
    • /
    • pp.88-99
    • /
    • 2021
  • In this study, a land-based marine closed mesocosm (LMCM) experiment was performed to objectively assess the initial stability of an artificial ecosystem experiment against biological and non-biological factors when evaluating ecosystem risk assessment. Changes in the CV (coefficient of value) amplitude were used as data to analyze the stability of the experimental system. The CV of the experimental variables in the LMCM groups (200, 400, 600, and 1,000 L) was maintained within the range of 20-30% for the abiotic variables in this study. However, the difference in CV amplitude in biological factors such as chlorophyll-a, phytoplankton, and zooplankton was high in the 600 L and 1,000 L LMCM groups. This result was interpreted as occurring due to the lack of control over biological variables at the beginning of the experiment. In addition, according to the ANOVA results, significant differences were found in biological contents such as COD (chemical oxygen demand), chlorophyll-a, phosphate, and zooplankton in the CV values between the LMCM groups(p<0.05). In this study, the stabilization of biological variables was necessary to to control and maintain the rate of changes in initial biological variables except for controllable water quality and nutrients. However, given the complexity of the eco-physiological activities of large-scale LMCMs and organisms in the experimental group, it was difficult to do. In conclusion, artificial ecosystem experiments as a scientific tool can distinguish biological and non-biological factors and compare and analyze clear endpoints. Therefore, it is deemed necessary to establish research objectives, select content that can maintain stability, and introduce standardized analysis techniques that can objectively interpret the experimental results.

Physicochemical Properties of Red Ginseng on Storage Condition of the Fresh Ginseng (수삼의 저장조건에 따른 홍삼의 이화학적 특성)

  • Kim, Chun-Suk;Jung, In-Chan;Kim, Se-Bong;Yang, Deok-Chun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.1
    • /
    • pp.52-56
    • /
    • 2005
  • This study was compared the quality of red ginseng and characteristic changes of physicochemical properties according to the storage period (non storage, two days, six days, eight days, ten days) and store temperature $20^{\circ}C, \;34^{\circ}C,\;-10^{\circ}C)$. The water content of the fresh ginseng has a tendency to decrease as storage time increases. When we store the fresh ginseng for 10 days, the ideal storage temperature is considered to be $34^{\circ}C$ degrees. The amount of total nitrogen has a tendency to increase more than that of no storage as storage period approaches to 10 days. In the storage temperature, the amount of total nitrogen has a tendency to increase in the order of 1) room temperature, 2) freezing storage, 3) cold storage more than no storage. Cold storage has larger contents of total phenolic compounds than room temperature and freezing storage according to storage temperature. When we analyze the changes of a relative density of eight elements, ginsenoside $Rb_1,Rb_2,Rc,Rd,Re,Rg_3,Rg_1\;and\;Rg_2$ in red ginseng's saponin Rf according to storage condition, the relative density of $Rb_1\;and\;Rg_1$ against Rf diminishes in each storage condition as storage time increases. And it is also thought that density change of ginsenoside appears because of the materials, and change tendency according to storage condition is not clear. From functional nature on the evaluation of the quality, taste and fragrance of red ginseng according to storage district, it is evaluated that it is most recommendable for red ginseng to be transported and stored in $3{\sim}4$ degrees to keep its best condition.

Evaluation of Contamination Level of the Sediments from Chusori and Chudong Areas in Daechung Reservoir (대청호 추소 및 추동 수역 퇴적물의 오염도 평가)

  • Oh, Kyoung-Hee;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.277-284
    • /
    • 2015
  • In order to analyze the contamination level of sediment samples taken from Chusori and Chudong areas in Daechung Reservoir, the particle size and concentrations of organics and nutrients were analyzed and phosphorus fractionation analysis was conducted. The average fraction of silt-sized particles was 92% in the sediments taken from Chudong area and Chusori area at the site adjacent to main current, which was higher than that from the upper Chusori area. The concentrations of total phosphorus in the sediments at Chusori and Chudong area were 999 (${\pm}98$) and 1,123 (${\pm}119$) mg/kg sediment, respectively. The fractions of autochthonous phosphorus, which can be readily eluted by change of environmental conditions, were much higher than those of allochthonous phosphorus, indicating the internal load can contribute the eutrophication in these areas. The concentrations of total nitrogen were over 5,600 mg/kg sediment in all samples, which is the guideline of Contamination Assessment of River and Lake Sediments of the Ministry of Environment, indicating the contamination level of total nitrogen is serious in the sediments. It is concluded that the countermeasures to manage the quality of sediments are required to improve the water quality in the Daechung Reservoir.

Assessment on the Mechanical-Chemical Stabilities of Coal Ash Blocks in Sea Water (석탄회 블록의 해양환경에서 역학적-화학적 안정성 평가)

  • Kim, Pil-Geun;Sung, Kyu-Youl;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.41 no.4
    • /
    • pp.383-392
    • /
    • 2008
  • This study aims to evaluate the mechanical-chemical stability of used coal ash blocks, for improving fishing grounds. The surface of weathered ash blocks in seawater showed a decrease in the Ca and an increase in the Mg contents, compared to that of fresh blocks. This result reflects the substitution of Ca by Mg in seawater. The compressive strengths of ash blocks submerged into seawater during 12 months ranged from 235.23 to $447.43\;kgf/cm^2$; this is higher than the standard strength of wave-absorbing blocks($180\;kgf/cm^2)$ that are used for harbor construction. In addition, the compressive strength of ash blocks tends to increase with increasing installation time in seawater. The result of leaching experiments on coal ash blocks by Korean Standard Leaching Test(KSLT) method showed that leached concentrations of most metals except Cr(that leached up to 50 ppb, approaching standard concentration) do not exceed the seawater quality standards. A long-term(112 days) heavy metal leaching test to analyze seawater without mixing-dilution also showed that the concentrations of leached heavy metals, except for Cu, under anaerobic conditions do not exceed the seawater quality standards. Accordingly, the use of coal ash blocks in marine environments appears to be safe from chemical and mechanical factors that decrease the efficiency of concrete. Also, leaching concentration of Cu seems to be stable by decrease of leaching concentration due to dilution of seawater.

A Study of Optimal Conditions in Distillation for Production of Schisandra Chinensis Fruit Spirits (오미자 과실 증류주의 제조를 위한 증류 최적조건 연구)

  • Cho, Hye-Seom;Cheong, Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6142-6151
    • /
    • 2015
  • This study is conducted to develop and optimize fruit spirits by using Schizandra chinensis fruit which are rarely used as spirits in the world. For this purpose, the raw material, main compounds of fermented mash and, quality characteristics of distilled liquor prepared with different distillation methods were analyzed. The studt period lasted six months and the results were follows. Schizandra chinensis was not suitable for alcohol fermentation because the sugar concentration and acidity were low. Therefore, the fermentation condition was appropriate to mix with the weight ratio of fresh Schizandra chinensis fruit, water and sugar as 1:1.5:0.25, and was fermented the mix by adding 0.06 w/w% of $(NH_4)_2HPO_4$ compared to the must total weight. It was also examined to analyze product characteristics of fruit spirits prepared with different methods of distillation(column-pot still, pot still, vacuum still). The result showed that fruit spirits made by vacuum still with fresh Schizandra chinensis fruit indicated the best product quality while the distillation of column-pot still showed the best yield.

Edge Enhancement for Vessel Bottom Image Considering the Color Characteristics of Underwater Images (수중영상의 색상특성을 고려한 선박하부 영상의 윤곽선 강조 기법)

  • Choi, Hyun-Jun;Yang, Won-Jae;Kim, Bu-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.926-932
    • /
    • 2017
  • Image distortion can occur when photographing deep sea targets with an optical camera. This problem arises because sunlight is not sufficiently transmitted due to seawater and various floating particles of dust. Particularly, color distortion takes place, causing green and blue color channels to be over emphasized due to water depth, while distortion of boundaries also occurs due to light refraction by seawater and floating particles of dust. These distortions degrade the overall quality of underwater images. In this paper, we analyze underwater images of the bottom of vessels. Based on the results, we propose a technique for color correction and edge enhancement. Experimental results show that the proposed method increases edge clarity by 3.39 % compared to the effective edges of the original underwater image. In addition, a quantitative evaluation and subjective image quality evaluation were concurrently performed. As a result, it was confirmed that object boundaries became clear with color correction. The color correction and contour enhancement method proposed in this paper can be applied in various fields requiring underwater imaging in the future.

Development of analytical method for the isotope purity of pure D2 gas using high-precision magnetic sector mass spectrometer

  • Chang, Jinwoo;Lee, Jin Bok;Kim, Jin Seog;Lee, Jin-Hong;Hong, Kiryong
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.205-211
    • /
    • 2022
  • Deuterium (D) is an isotope with one more neutron number than hydrogen (H). Heavy elements rarely change their chemical properties with little effect even if the number of neutrons increases, but low-mass elements change their vibration energy, diffusion rate, and reaction rate because the effect cannot be ignored, which is called an isotope effect. Recently, in the semiconductor and display industries, there is a trend to replace hydrogen gas (H2) with deuterium gas (D2) in order to improve process stability and product quality by using the isotope effect. In addition, as the demand for D2 in industries increases, domestic gas producers are making efforts to produce and supply D2 on their own. In the case of high purity D2, most of them are produced by electrolysis of heavy water (D2O), and among D2, hydrogen deuteride (HD) molecules are present as isotope impurities. Therefore, in order to maximize the isotope effect of hydrogen in the electronic industry, HD, which is an isotope impurity of D2 used in the process, should be small amount. To this end, purity analysis of D2 for industrial processing is essential. In this study, HD quantitative analysis of D2 for high purity D2 purity analysis was established and hydrogen isotope RM (Reference material) was developed. Since hydrogen isotopes are difficult to analyze with general gas analysis instrument, they were analyzed using a high-precision mass spectrometer (Gas/MS, Finnigan MAT271). High purity HD gas was injected into Gas/MS, sensitivity was determined by a signal according to pressure, and HD concentrations in two bottles of D2 were quantified using the corresponding sensitivity. The amount fraction of HD in each D2 was (4518 ± 275) μmol/mol, (2282 ± 144) μmol/mol. D2, which quantifies HD amount using the developed quantitative analysis method, will be manufactured with hydrogen isotope RM and distributed for quality management and maintenance of electronic industries and gas producers in the future.