• Title/Summary/Keyword: Water quality analyze

Search Result 579, Processing Time 0.033 seconds

Feasibility Study of On-site Analysis on Ammonium ion (암모늄이온의 현장 분석 방법 개발에 관한 기초 연구)

  • Jung, Yong-Jun
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.275-280
    • /
    • 2014
  • Because ammonia in water body can cause water pollution as a result of generating ammonium ion, it is of importance in the management of water quality. This work performed to analyze the ammonium ion by measuring the color band length on the basis of modifying the indophenol method. When 1-naphthol was employed as a coloring agent, the maximum absorbance was shown near 720nm, where the proper injection was in the range of 0.5-1.5ml. About 80% of absorbance was observed after the color development was made within the 20 minutes. In the manufacturing of coloring agent, the proper concentration of NaOH was 1.5-2.5M, and the effect of pH on the color development is negligible. In addition, the color development was effectively in the region of room temperature.

Temporal and Spatial Analysis of BOD data in Namgang-Dam Watershed for TMDLs (오염총량관리를 위한 남강댐유역 수질자료의 시.공간적 특성 분석)

  • Kim, Sang-Min;Kim, Sung-Min;Park, Tae-Yang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1355-1359
    • /
    • 2010
  • The purpose of this study is to analyze the spatial characteristics of Namgang-Dam watershed for a Total Maximum Daily Loads(TMDL). Three TMDL target sites, Gyeonghogang1, 2, Namgang-Dam2, are located within Namgang-Dam watershed. Under the current criterion for TMDLs, 3-year arithmetic mean BOD concentration of the target sites should not exceed the target concentration for 2 consecutive years. Two and three times of violation were observed for Gyenghogang2 and Namgang-Dam2 sites while no violation was found for Gyeonghogang1 site. However, no violation was found since 1999 for all three sites. Correlation between each 12 stations within the watershed were analyzed and cluster analysis was conducted to figure out the spatial characteristics of the watershed. Correlation coefficient between Gyonghogang1 and 2 was high (0.758) while the coefficients between lake station (Namgang-Dam2) and stream stations (Gyonghogang1 and 2) were very low. Dendrogram indicated that all of three Namgang-Dam stations were very close and Gyenghogang1, 2 stations were also close.

  • PDF

Designing of the Beheshtabad water transmission tunnel based on the hybrid empirical method

  • Mohammad Rezaei;Hazhar Habibi
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.621-633
    • /
    • 2023
  • Stability analysis and support system estimation of the Beheshtabad water transmission tunnel is investigated in this research. A combination approach based on the rock mass rating (RMR) and rock mass quality index (Q) is used for this purpose. In the first step, 40 datasets related to the petrological, structural, hydrological, physical, and mechanical properties of tunnel host rocks are measured in the field and laboratory. Then, RMR, Q, and height of influenced zone above the tunnel roof are computed and sorted into five general groups to analyze the tunnel stability and determine its support system. Accordingly, tunnel stand-up time, rock load, and required support system are estimated for five sorted rock groups. In addition, various empirical relations between RMR and Q i.e., linear, exponential, logarithmic, and power functions are developed using the analysis of variance (ANOVA). Based on the significance level (sig.), determination coefficient (R2) and Fisher-test (F) indices, power and logarithmic equations are proposed as the optimum relations between RMR and Q. To validate the proposed relations, their results are compared with the results of previous similar equations by using the variance account for (VAF), root mean square error (RMSE), mean absolute percentage error (MAPE) and mean absolute error (MAE) indices. Comparison results showed that the accuracy of proposed RMR-Q relations is better than the previous similar relations and their outputs are more consistent with actual data. Therefore, they can be practically utilized in designing the tunneling projects with an acceptable level of accuracy and reliability.

A Study on Impact Assessment for Application of Strengthened Compliance Concentration of Effluent Limit from PSTWs in the Jinwee-stream Watershed (유역하수도에서 강화된 방류수 수질 준수농도 적용을 위한 진위천수계 수질영향 평가)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Ki-Hong;Ryu, Jichul;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.397-406
    • /
    • 2015
  • The different compliance concentration of effluent limit is applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof in accordance with the enforced Watershed Sewer System Maintenance Plan in 2013. It is necessary to set the compliance concentration of effluent limit for PSTWs in watershed sewer system, in order to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentration of effluent limit for PSTWs under the plan. The agencies have a plan to apply strengthened effluent BOD concentration limits for PSTWs in I to IV area grade, respectively. Effluent BOD concentration limits will be strengthened from 5~10 mg/L to 3 mg/L in II~III area grade, from 10 mg/L to 5 mg/L in IV area grade. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents assessment methodology which analyze for the compliance concentration of effluent limit to affect water quality of discharge watershed using simulation model for the Jinwee-stream watershed.

The influence of chemical water quality on fish trophic guilds, pollution tolerance, and multi-metric ecological health in the main streams of Mangyeong River (만경강 본류의 어류 트로픽 길드, 오염 내성도 및 다변수 생태건강도에 대한 화학적 수질영향)

  • Na, Hyun-Hee;Lee, Sang-Jae;An, Kwang-Guk
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.1
    • /
    • pp.8-18
    • /
    • 2019
  • The objectives of this study were to analyze the influence of chemical water quality on fish guilds, pollution tolerance and the multi-metric ecological health, based on the Fish Assessment Index (FAI) in the main stream of Mangyeong River between 2009-2016. The quality of water with specific conductivity, TP, and $NH_4-N$ got worse dramatically in the down region. During the study, a total of 50 species were collected and the most dominant species was Zacco platypus. Also known as tolerant species, accounted 22.9% of the total abundances, thus indicating a trophic degradation. The downstream region (S5) had the highest number of fish external abnormalities, indicating a degradation of ecological health, based on the fish assemblages. Pearson correlation analysis indicated that relative abundance of tolerant fish species and omnivore fish species had a significant positive correlation(r>0.30, p<0.05) with values of BOD, conductivity and $NH_4-N$. Whereas, the relative abundance of the sensitive species and insectivore species had a significant negative relations (r<-0.30, p<0.001) with the parameters. The mean obtained from the multi-metric fish model, based on the FAI of all sites was 47 (n=40). This indicated a "fair condition" in the ecological health, and the downstream regions (S3-S5) were judged as "bad condition", indicating an influence of the chemical degradation on the ecological health.

Analysis of Influential Factors from Rainfall to Stream Water Quality in Small Forested Watershed - pH, dissolved oxygen, electrical conductivity - (산림유역내(山林流域內) 강수(降水)로부터 계류수질(溪流水質)에 미치는 영향인자(影響因子) 분석(分析) - pH, 용존산소(溶存酸素), 전기전도도(電氣傳導度) -)

  • Park, Jae-Hyeon;Woo, Bo-Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.4
    • /
    • pp.489-501
    • /
    • 1997
  • This research was conducted to analyze the influence of the environmental factors on water quality such as pH, dissolved oxygen, and electrical conductivity of rainfall, throughfall, soil water(A and B layer), and stream water quality at a small forested watershed. Rainfall, throughfall, soil water(A and B layer), and stream water were sampled at the study sites in Kwanak Arboretum, Seoul National University in Mt. Kwanak for 14 months(Jul. 1, 1996~Aug. 31, 1997). Average rainfall pH value was 6.06(ranged from 5.02 to 6.60). Acid rain frequency(less than pH 5.6) was 16.7%. The lowest rainfall pH value was 5.02. Average of pH values in hydrological processes were decreasing in the following order, stream water>soil water [Prunus serrulata var, spontanea(B layer>A layer)]>throughfall(Prunus serrulata var. spontanea)>soil water [Carpinus laxiflora(B layer >A layer)]>throughfall(Carpinus laxiflora)>rainfall>soil water [Pinus rigida(B layer>A layer)]>throughfall(Pinus rigida). pH values of throughfall in Prunes serrulata var. spontanea and Carpinus laxiflora were higher in Pines rigida. Average of dissolved oxygen values in hydrological processes were decreasing in the order, stream water>throughfall(Carpinus laxiflora>Prunus serrulata var, spontanea>Pines rigida)>rainfall>soil water [Prunes serrulata var. spontanea(A layer)>Pines rigida(A layer)>Carpinus laxiflora(A layer)>Prunes serrulata var. spontanea(B layer)>Pines rigida(B layer)>Carpinus laxiflora(B layer)]. And average electrical conductivity values in hydrological processes were decreasing in the order, soil water (B layer>A layer)>throughfall(Pinus rigida>Prunes serrulata var, spontanea>Carpinus laxiflora)>stream water>rainfall. Multiple regression equations of electrical conductivity and $Mg^{2+}$, $Na^+$, total amount of cation, total amount of ion, and no. of before non-rain days in rainfall, throughfall, soil and stream water shows high significance(Multi R; 0.84).

  • PDF

Case Study of Quality Assurance for MDCT Image Quality Evaluation Using AAPM CT Performance Phantom (AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의 영상 평가를 위한 정도관리 사례 연구)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.7
    • /
    • pp.114-123
    • /
    • 2007
  • The increasing use of computed tomography (CT) as a diagnostic tool creates the need from and efficient means of evaluating the performance of the CT scanner now in use. Accordingly, acceptance testing and quality assurance of CT is of great importance. The aim of this study is to analyze of AAPM CT performance phantom in the CT accreditation program. The modular phantom offers the CT system with which to measure eight performance parameters. The parameters are listed of CT attenuation coefficient of water, noise, uniformity, spatial resolution, contrast resolution, slice thickness (5 and 10 mm), artifacts and alignment. The phantom evaluation was done by two radiologists. The acceptance testing protocol described here in demonstrates the successful of the guidelines for the quality assurance using AAPM CT performance phantom. We need to be upgraded for the CT image quality and make the standard reference of the quality assurance in the CT.

Analysis of the Visual Quality of Riverfront Skyline Through the Feature of Height and Spatial Arrangement of Tall Building

  • Puspitasari, Ayu Wandira;Kwon, Jongwook
    • Architectural research
    • /
    • v.21 no.4
    • /
    • pp.91-98
    • /
    • 2019
  • In modern times, numerous cities are competing to create the unique skyline adjacent to the water. Tall buildings located across the river have a great contribution to the skyline of a riverfront city and can be a precious asset for the city. Moreover, in several cities, tall buildings and their impact on the urban skyline are a matter that should be considered and regulated in urban design. Therefore, as a prominent element in a larger visual setting of the city, tall buildings should improve the visual quality of the skyline rather than diminish that quality. This research attempts to provide an objective method to analyze the visual quality of the skyline made by a group of tall buildings through their feature of heights and spatial arrangement from riverfront views. The analysis is determined by the design variables of building heights variation, heights transition, density, and spacing of a group of tall buildings. A comparative case study of tall buildings in Yeouido and Lujiazui was conducted to prove the effectiveness of the analysis. The proposed method can be used in a simple way in the quantitative approach to quantify the visual quality of the skyline. In conclusion, Yeuido's skyline is not quite interesting from the riverfront view in terms of height variation and continuity of the skyline view because they are dispersed. Conversely, Lujiazui's skyline from the riverfront vantage points has a good quality in all aspects of the feature of height and spatial arrangements of tall buildings cluster. These factors can be used for the urban designer on how proposed tall buildings within the cluster should appropriately respond to adding image on the skyline.

The application of ecosystem model for the eutrophication control in Masan Bay in summer (하계 마산만의 부영양화 제어를 위한 생태계모델의 적용)

  • Kim, Jong-Gu;Park, Cheong-Gil;Kim, Gwang-Su
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.185-195
    • /
    • 1994
  • Masan bay is one of the polluted enclosed bays, which has red tides problem and the formation of oxygen deficient water in the bottom layer. Most important factors that cause eutrophication and red tide is nutrient materials containing nitrogen and phosphorus which stem from terrestrial sources and nutrients released from sediment. Therefore, to improve of water quality, reduction of these nutrient loads should be indispensible. At this study, the three-dimensional numerical hydrodynamic and eutrophication model, which were developed by Institute for Resources and Environment of Japan, were applied to analyze the processes affecting the phytoplankton production and also to evaluate the effect of water quality improvement plans on phytoplankton production. In field sorvey, the range of concentrations of chlorophyll-a at surface area was found to be 29.17 - 212.5mg/m3, which were exceeding eutrophication criteria. The constant currents defined by integrating the simulated tidal currents over 1 tidal cycle showed the counterclockwise eddies in the southern part of Budo. The general directions of constant currents were found to be southward at surface and northward at bottom over all the bay. The eutrophication model was calibrated with the data surveyed in the field area in June, 1993. The calculated results are in fairly good agreement with values within relative error of 30%. The pollutant load from the sources such as the input from terrestrial release from the sediment was reduced by the rate of 50, 70, 90, 98% to effect of phytoplankton production. Phytoplankton production was reduced to of the 90% reduction of the input loads from terrestrial sources and 8% in 90% reduction of the load from sediment.

  • PDF

Preliminary Ecological Assessments of Water Chemistry, Trophic Compositions, and the Ecosystem Health on Massive Constructions of Three Weirs in Geum-River Watershed

  • Ko, Dae-Geun;Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • v.39 no.1
    • /
    • pp.61-70
    • /
    • 2016
  • Major objectives of the study were to analyze chemical and biological influences of the river ecosystem on the artificial weir construction at three regions of Sejong-Weir (Sj-W), Gongju-Weir (Gj-W), and Baekje-Weir (Bj-W) during 2008-2012. After the weir construction, the discharge volume increased up to 2.9 times, and biological oxygen demand (BOD) and electrical conductivity (EC) significantly decreased (p < 0.05). Also, the decrease of total phosphorus (TP) was also evident after the weir construction, but still hyper-eutrophic conditions, based on criteria by , were maintained. Multi-metric model of Index of Biological Integrity (IBI) showed that IBI values averaged 21.0 (range: 20-22; fair condition) in the Bwc, and 14.3 (range: 12-18; poor condition) in the Awc. The model values of IBI in Sj-W and Gj-W were significantly decreased after the weir construction. The model of Self-Organizing Map (SOM) showed that two groups (cluster I and cluster II) of Bwc and Awc were divided in the analysis based on the clustering map trained by the SOM. Principal Component Analysis (PCA) was similar to the results of the SOM analysis. Taken together, this research suggests that the weir construction on the river modified the discharge volume and the physical habitat structures along with distinct changes of some chemical water quality. These physical and chemical factors influenced the ecosystem health, measured as a model value of IBI.