• Title/Summary/Keyword: Water qualities

Search Result 648, Processing Time 0.027 seconds

An Experimental Study on the Properties of Water Cooled Blast Furnace Slag as a Fine Aggregate for Concrete (콘크리트용 잔골재로서 고로수쇄(高爐水碎)슬래그의 물성(物性)에 대한 실험적(實驗的) 연구(硏究))

  • Moon, Han Young;Choi, Yun Wang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • This paper is the part of fundamental study considering whether the unprocessed water cooled blastfurnace slag, by-product of iron works, can be useful for some fine aggregate of mortar and concrete. The acquired results in this study show that the qualities of the water cooled blastfurnace slag produced in the state of raw material in the country in not good for using as a fine aggregate of mortar and concrete. To be used as a fine aggregate of concrete the qualities need to be improved in the process of manufacture.

  • PDF

The Monitoring of Biogeochemical Interactions Between Sediment and Water: a Mesocosm Study

  • Yang, Jae-Sam;Kim, Yeong-Tae;Choi, Kang-Won
    • Journal of the korean society of oceanography
    • /
    • v.39 no.1
    • /
    • pp.107-118
    • /
    • 2004
  • A series of mesocosm experiments has been conducted to investigate the effects of sediment on the qualities of superficial water over the tidal flats. The experiments involved two different kinds of sediments (Silt and Fine Sand) to mimic the natural habitats. Other environmental conditions in the mesocosm were kept as natural as possible. The mesocosm coincided with the annual patterns of the natural water qualities and was identical with the composition of benthic organisms of three reference sites of natural tidal flats. DIP has been leached out from sediment from June to October, but not for ammonium and DIN. The mesocosm was successfully able to simulate the environmental situations of natural tidal flat and will be a useful tool to assess the environmental impacts by human activities.

Long-Term Trend Analyses of Water Qualities in Nakdong River Based on Non-Parametric Statistical Methods (비모수 통계기법을 이용한 낙동강 수계의 수질 장기 경향 분석)

  • Kim, Joo-Hwa;Park, Seok-Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 2004
  • The long-tenn trend analyses of water qualities were performed for 49 monitoring stations located in Nakdong River. Water quality parameters used in this study are the monthly data of BOD(Biological Oxygen Demand), TN(Total Nitrogen) and TP(Total Phosphorus) measured from 1990 to 1999. The long-tenn trends were analyzed by Seasonal Mann-Kendall Test and Locally WEighted Scatter plot Smoother(LOWESS). Nakdong river was divided into four subbasins, including upstream watershed, midstream watershed, western downstream watershed and eastern downstream watershed. The results of Seasonal Mann-Kendall Test indicated that there would be no trends of BOD in upstream watershed, western and eastern downstream watershed. Trends of BOD were downward in midstream watershed. For TN and TP, there were upward trends in all of watersheds. But LOWESS curves suggested that BOD, TN and TP concentrations generally increased between 1990 and 1996, then resumed decreasing.

Effects of flushing techniques on water quality at extremity with low chlorine residuals in drinking water distribution systems (수질 취약지역 및 관말에서 플러싱 적용 먹는물 수질 개선 효과)

  • Ko, Kyung-Hoon;Kweon, Ji-Hyang;Kim, In-Ja;Lim, Woo-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.313-324
    • /
    • 2011
  • Several complaints from consumers on red or turbid waters were often filed at the same places although various efforts were made to improve water quality in the drinking water plant. The red water problems were occurred due to corrosion of main water pipe, especially at extremity. The low concentrations of chlorine indicating poor water quality were detected at the problematic location. To solve the poor water quality at the extremity, flushing techniques, i.e., conventional flushing, unidirectional flushing, and continuous flushing, were recently practiced. In this study, effects of conventional flushing on water qualities were examined by comparing turbidity and residual chlorine before and after flushing. In addition, more detailed analyses on water qualities at the tap water were conducted to learn a reduction pattern during flushing. Five items from geographic information system of water distribution were used to obtain a relationship with water quality, washing duration or amounts of washing water. The flushing was effective to meet the National Drinking Water Quality Standard with simple and relatively short time operation. The key operational parameter in flushing was amounts of washing water which should be estimated based on water quality of the consumer's tap water. The positive relationship between the residual chlorine and pipe length implied that detention time in the pipeline was the main cause of the complaints. More experiments on effectiveness of flushing are needed to determine reasonable strategies of flushing.

Application of HSPF Model for Effect Analyses of Watershed Management Plans on Receiving Water Qualities (유역관리에 따른 수질개선 효과분석을 위한 HSPF 모델 적용)

  • Song, Hye-Won;Lee, Hye-Won;Choi, Jung-Hyun;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.358-363
    • /
    • 2009
  • The HSPF (Hydrological Simulation Program-Fortran) model was applied to the Kyoungan stream watershed to analyze effects of watershed management plans on receiving water qualities. Utilizing BASINS 3.1 GIS program, the Kyoungan stream watershed was divided into 57 sub-basins and model input parameters were obtained, from DEM (Digital Elevation Model), land use type, stream map, and wastewater treatment facilities, etc.. The hydrologic module of the model was validated based on the measured meteorological data and stream flow data. Then the model was calibrated and verified against the field measurements of water qualities, including temperature, DO, BOD, $NO_3-N$, $NH_3-N$, Org-N, TN and TP. In most cases, there were reasonable agreements between measurements and predictions. The validated model was used to analyze the water quality improvements in the main stream of Kyoungan stream according to the watershed management plans in sub-basins, which are three different scenarios: water quality improvement in tributaries through watershed management activities, expansion and up-grade of wastewater treatment plants, and application of first and second scenarios together. It was concluded that expansion and upgrade of wastewater treatment plants would be more effective than watershed management activities. In order to improve water qualities to the satisfactory level, both watershed management and point source control must be required in the Kyoungan stream.

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Investigation of water qualities and microbials on the flow-through olive flounder, Paralichthys olivaceus farms using coastal seawater and underground seawater in Jeju (연안해수와 지하해수를 사용하는 제주 넙치 양식장의 수질과 미생물 변동)

  • KIM, Youhee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • This study assessed the levels of water qualities and microbials contamination of inland olive flounder farms in Jeju in the summers from 2015 to 2017. Three farms (A-C) located in a concentrated area using mixing coastal seawater and underground seawater and one farm (D) located in an independent area using only coastal seawater were selected. Total ammonia nitrogen (TAN) reached a maximum of 0.898 ± 1.024 mg/L as N in the coastal seawater of A-C, which was close to the limit of the water quality management goal of the fish farm. TAN in the influent from A-C was up to three times higher than that of D, so that the discharged water did not spread to a wide range area along the coast and continued to affect the influent. TAN of the effluent in A-C increased by 2.7-4.6 times compared to the influent, resulting in serious self-pollution in the flounder farm. Heterotrophic marine bacteria in the influent of A-C was about 600 times higher than D, and the discharge of A-C was increased by about 30 times compared to the influent.

Characteristics of Quality and Flow of Water Resources at Palaces in Seoul Metropolitan (서울 시내 궁궐 수원의 수질과 유동 특성)

  • Naranchimeg., B;Lee, Jae-Min;Woo, Nam-C.;Kim, Youn-Tae;Lee, Kang-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.2
    • /
    • pp.61-76
    • /
    • 2011
  • This study was objected to provide suggestions for best management practices to restore the cultural and historical values of the wells in Palaces as well as their water qualities. Water resources in the five Palaces in Seoul Metropolitan, including Gyeongbokgung, Changdeokgung, Changgyeonggung, Jongmyo Shrine, and Deoksugung, were surveyed for their physical flows and chemical compositions from April to July in 2010. Ground waters in most wells were found at depths within 5 m from the ground surface, showing typical water-table aquifer systems. Hydraulic gradients indicate water resources in Gyeongbokgung, Changdeokgung, and Changgyeonggung flowing toward south, and toward east in Deoksugung area. Especially, water-level fluctuation data at S-10 in Deoksugung implied the influence of groundwater discharge facility. In Jongmyo Shrine, water was not detected in wells, indicating the water level was lower than the well depth. Based on the water chemistry and stable isotope analyses, water resources and their qualities appeared to be formed by the water-rock interaction along the groundwater paths. S-10 (Deoksugung) and S-14 (Changgyeonggung) samples were contaminated with nitrate ($NO_3$) in levels of higher than Korean drinking water standard, 10 mg/L as $NO_3$-N, but once in four sampling campaigns. In the situation that water resources in Palaces still maintain natural characteristics, the materials that will be used for the restoration and improvement of the Palace water supplies should be carefully selected not to disturb the natural integrity. In addition, because the wells are located in the center of metropolitan area, a systematic monitoring should be applied to detect and to manage the potential impacts of underground construction and various pollution sources.

Forecasting of Stream Qualities at Gumi industrial complex by Winters' Exponential Smoothing

  • Song, Phil-Jun;Um, Hee-Jung;Kim, Jong-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.4
    • /
    • pp.1133-1140
    • /
    • 2008
  • The goal of this paper is to analysis of the trend for stream quality in Gumi industrial complex with Winters' exponential smoothing method. It used the five different monthly time series data such as BOD, COD, TN, TP and EC from January 1998 to December 2006. The data of BOD, COD, TN, TP and EC are analyzed by time series method and forecasted the trends until December 2007. The stream qualities change for the better about BOD, COD, TN and TP, but the stream qualities resulted by EC is still serious.

  • PDF