• Title/Summary/Keyword: Water purification technology

Search Result 295, Processing Time 0.03 seconds

The case study on wireless lan design technique for Bansong purification plant using network integrated management system and security switch (네트워크 통합관리시스템과 보안스위치를 이용한 반송정수장 무선랜 구축사례)

  • Park, Eunchul;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.309-315
    • /
    • 2018
  • Currently, the commercialization of the $5^{th}$ Generation (5G) service is becoming more prevalent in domestic communication network technology. This has reduced communication delay time and enabled large-capacity data transmission and video streaming services in real-time. In order to keep pace with these developments, K-water has introduced a smart process control system in water purification plants to monitor the status of the water purification process. However, since wireless networks are based on the public Long Term Evolution (LTE) network, communication delay time remains high, and high-resolution video services are limited. This is because communication networks still have a closed structure due to expense and security issues. Therefore, with 5G in its current form, it is very difficult to accommodate future services without improving the infrastructure of its communication networks. In recognition of these problems, this study implemented the authentication and management function of wireless networks on a wired network management system in the K-water Bansong water purification plant. The results confirmed that wired Local Area Network (LAN) services give a higher security performance than an expensive commercial wireless LAN system. This was achieved by using an Internet Protocol (IP) address management system of wired networks and the packet filtering function of the Layer2 (L2) switch. This study also confirmed that it is possible to create a wireless LAN service that is 3.7 times faster than the existing LTE communication network.

An Experimental Basic Study of Water Purification Function due to Spit in Small Estuary (하구에 형성된 소규모 모래톱의 수질정화 기능에 관한 기초적 연구)

  • Park, Sang-Kil;Kim, Byung-Dal;Jeong, Seong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.3 s.76
    • /
    • pp.8-15
    • /
    • 2007
  • This study is intended to examine the relationship between the magnitude of sand spit in the estuary of the stream and improvement of the quality of water that flaws into the sea, by means of hydraulic experimentation. In order to determine the effect of improvements of water quality when river flow is stagnant, the estuary flows into the sea through the small sand spit, and a two-dimensional physical model experiment was carried out. Distribution of concentration was decreased in response to an increase in length of sand spit and time. The experimental results are compared with theoretical results, based on the solution of the equation. Also, there are functions of influx prevention of salt wedge and purification of pollution water due to sand spit in small estuary.

Performance and Operation of Biological Activated Carbon (생물활성탄접촉조의 성능과 조작)

  • Lee, Gangchoon;Yoon, Taekyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.83-90
    • /
    • 2006
  • Performance and operation of BAC in ozone-BAC advanced water treatment process were investigated using the pilot scale test plant built in D water purification plant. The performance was evaluated by the removal efficiencies of DOC, BDOC, ammonia nitrogen and THMs. The effect of EBCT on DOC removal was experimented for an effective operating condition, and the amount of attached biofilm was analyzed in various water temperatures and position of BAC. Two removal mechanisms, adsorption and biological decomposition by attached biofilm, were predominant to decrease the concentration of various contaminants. DOC was removed 40%, and the removal rate was decreased in winter time due to the lowered activity of attached biofilm. BDOC was effectively removed. THMs and ammonia nitrogen were mainly removed not in ozonation process but in BAC. Water temperature deeply influenced in removal efficiency of ammonia nitrogen. The amount of attached biofilm depended on water temperature and height of packed activated carbon column. Considering DOC removal efficiency and design EBCT of commercial BAC plant, the proper EBCT was 12.5 minutes.

An Ecological Restoration of Treatment Wetland and Urban Upper Stream for Reusing Sewage Treatment Water - In the case of Sustainable Structured Wetland Biotop System at Upper Part of Jaemin Stream in Gongju-si, Korea - (하수처리수의 재이용을 위한 처리습지 및 도시 상류하천 생태환경복원 - 공주시 제민천 생태적수질정화비오톱을 중심으로 -)

  • Byeon, Chan-Woo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.5
    • /
    • pp.65-77
    • /
    • 2014
  • The ecosystem of Jaemin stream, flowing into the center of Gongju-si, had been damaged by low water quality and lack of water quantity of the steam. However, after applying the SSB (Sustainable Structured wetland Biotop) system to the flood plain and the upstream of Jaemin stream, the efficiency of ecological water purification and ecological restoration are as follows. Through the constant maintenance and monitoring from year 2009 to year 2013 after restorative design and construction the average influent concentration of BOD5 was 4.2 mg/L, and the average effluent concentration was 1.8 mg/L, reaching ecological water purification rate of 57%. As for the T-N, the average influent concentration was 9.983 mg/L, and the average effluent concentration was 6.303 mg/L, showing the rate of 37%. For the T-P, the average influent concentration was 0.198 mg/L, and the average effluent concentration was 0.098 mg/L, being the rate of 51%. The vegetation of Jaemin stream monitored for 2 years after the restoration was composed of 51 species in 28 families which show high ratio of planted native species. As for the animals in the site, 5 species in 3 families of reptiles and amphibians, 34 species of 23 families of birds, and 3 species in 2 families of mammals were monitored, indicating that the bio-diversity of the site has improved, as well.

Performance Evaluation of Soil Media for Water Quality Purification at LID Application (분산형 빗물관리시설 적용을 위한 수질정화기능 여재 성능 평가)

  • Park, Chan Gi;Kim, Chun Soo;Kim, Hwang Hee;Yoo, Sung-Yeol;Jeon, Ji Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.85-91
    • /
    • 2014
  • In this study, the water quality purification of new medias which were NPS media, hyugato, mineral stone, charcoal for applying soil media of Integrated Management Practices (IMPs) of Low Impact Development (LID) were evaluated. The influent concentrations of COD, T-N, and T-P were 117.8 mg/L, 17.1 mg/L, and 2.062 mg/L, respectively. The infiltration capacities of NPS media, hyugoto, mineral stone, charcoal, and gravel were $7.1{\times}10m/s$, $7.3{\times}10^{-5}m/s$, $7.9{\times}10^{-5}m/s$, $6.0{\times}10^{-5}m/s$, respectively. All media meet criteria of infiltration capacity as surface soil layer at IMPs which is over $1.0{\times}10^{-5}m/s$. Maximum removal rates of COD, T-N, and T-P occurred at Charcoal with 98 % of COD removal rate, NPS with 78 % of T-N removal rate, and hyugato with 75 % fo T-P removal rate, respectively. For more high removal efficiency of all water quality item, the mixed media which is 4.5(NPS media): 1(charcoal) : 4.5 (hyugato) as volume ratio was evaluated. The infiltration capacity of mixed media was $7.9{\times}10^{-5}m/s$ and met the criteria of infiltration as surface soil layer. The water quality removal efficiencies of mixed media were very high with showing 70 % for COD, 85 % for T-N, and 71 % for T-P. The mixed media could purify the water quality of surface runoff and was recommended to used at the LID site of ground water quality problem.

Research Trend of Membrane for Water Treatment by Analysis of Patent and Papers Publication (특허 및 논문 게재 분석을 통한 수처리용 분리막의 연구동향)

  • Woo, Chang Hwa
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.410-419
    • /
    • 2017
  • Since the beginning of the water shortage by disasters such as global warming, environmental pollution, and drought, development of original technology and studies have been undergone to increase availability of water resources. Among them the water treatment separation membrane technology is an environmentally friendly process that does not use chemicals and shows better water quality improvement effect than conventional physicochemical and biological processes. The water treatment membrane can be applied to various fields such as waste water treatment, water purification treatment, seawater desalination, ion exchange process, ultrapure water production, organic solvent separation and water treatment technology, and it tends to expand the range of application. In the core technology of water treatment membrane, researches are being actively carried out to develop a separation membrane of better performance by controlling the pore size to adjust the separation performance. In this review, we summarized the frequency of announcement by country and organization through the technological competitiveness evaluation of patents and papers of the water separation membrane. Also, we evaluated the results from membrane research for waste water treatment, water purification treatment, seawater desalination, ion exchange process and present the future direction of research.

Purification of the Waste Water Containing Natural Fatty Oil by Hydroxy Radical and Ozone (수산화라디칼과 오존에 의한 수중 천연 지방산 분해 제거 연구)

  • Mohammed, Latifatu;Won, Jung Ha;Kim, Yong Joo;Ko, Jang Myoun;Song, Keun Han;Lee, Chang Hoon
    • Korean Chemical Engineering Research
    • /
    • v.51 no.4
    • /
    • pp.523-526
    • /
    • 2013
  • In order to purify the waste water containing natural fatty oil, hydroxy radical and/or ozone are used to remove the fatty oil dispersed in the waste water. The fatty oil is decomposed by oxidation reaction through hydroxy radical and ozone, and eliminated as a function of first order reaction. It is clearly confirmed that the fatty oil in waste water can be effectively removed much more in the use of both hydroxy radical and ozone than only hydroxy radical as an oxydant. In addition, the decomposition chemical reaction mechanism of the fatty oil by hydroxy radical and ozone is proposed.

Effect on Corrosion Characteristics of SS 400 Steel by Alkali Water pH from Electrolysis of City Water (수돗물의 전기분해에 의해서 생성된 알카리수의 pH가 SS 400강의 부식특성에 미치는 영향)

  • Moon, Kyung-Man;Ryoo, Hae-Jeon;Kim, Yun-Hae;Jeong, Jae-Hyun;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • Many rivers and seas have been affected by environmental contamination. Therefore, city water supplies often require a high-degree purification treatment to provide safe drinking water. However, in order to achieve a high-degree purification treatment, a large amount of chlorine has to be added to sterilize city drinking water. The added chlorine reacts chemically with water and forms hypochlorous and chlorine ions. The hypochlorous ionizes with hypochlorous ions and hydrogen ions. As a result, the city water contains a large amount of chlorine ion. As such, when city water is used with domestic boilers, many kinds of heat exchangers, and the engines of vehicle and ships, there are often corrosion problems. In this study, alkali water was electrochemically made by electrolysis of city water, and corrosion properties between alkali and city water were investigated with an electrochemical method. Most of the chlorine ions are thought to not be contained in the alkali water because the alkali water is created in the cathodic chamber with an electrolysis process. In other words, the chlorine ion can be mostly removed by its migration from a cathodic chamber to an anodic chamber. Moreover, the alkali water also contains a large amount of hydroxide ion. The alkali water indicated relatively good corrosion resistance compared to the city water and the city water exhibited a local corrosion pattern due to the chlorine ion created by a high-degree purification treatment. In contrast, the alkali water showed a general corrosion pattern. Consequently, alkali water can be used with cooling water to inhibit local corrosion by chlorine ions in domestic boilers, various heat exchangers and the engine of ships and for structural steel in a marine structure.

Removal of Cs+, Sr2+, and Co2+ Ions from the Mixture of Organics and Suspended Solids Aqueous Solutions by Zeolites

  • Fang, Xiang-Hong;Fang, Fang;Lu, Chun-Hai;Zheng, Lei
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.556-561
    • /
    • 2017
  • Serving as an excellent adsorbent and inorganic ion exchanger in the water purification field, zeolite 4A has in this work presented a strong capability for purifying radioactive waste, such as $Sr^{2+}$, $Cs^+$, and $Co^{2+}$ in water. During the processes of decontamination and decommissioning of suspended solids and organics in low-level radioactive wastewater, the purification performance of zeolite 4A has been studied. Under ambient temperature and neutral condition, zeolite 4A absorbed simulated radionuclides such as $Sr^{2+}$, $Cs^+$, and $Co^{2+}$ with an absorption rate of almost 90%. Additionally, in alkaline condition, the adsorption percentage even approached 98.7%. After conducting research on suspended solids and organics of zeolite 4A for the treatment of radionuclides, it was found that the suspended clay was conducive to absorption, whereas the absorption of organics in solution was determined by the species of radionuclides and organics. Therefore, zeolite 4A has considerable potential in the treatment of radioactive wastewater.