• 제목/요약/키워드: Water pump

검색결과 1,494건 처리시간 0.03초

Pump availability prediction using response surface method in nuclear plant

  • Parasuraman Suganya;Ganapathiraman Swaminathan;Bhargavan Anoop
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.48-55
    • /
    • 2024
  • The safety-related raw water system's strong operational condition supports the radiation defense and biological shield of nuclear plant containment structures. Gaps and failures in maintaining proper working condition of main equipment like pump were among the most common causes of unavailability of safety related raw water systems. We integrated the advanced data analytics tools to evaluate the maintenance records of water systems and gave special consideration to deficiencies related to pump. We utilized maintenance data over a three-and-a-half-year period to produce metrics like MTBF, MTTF, MTTR, and failure rate. The visual analytic platform using tableau identified the efficacy of maintenance & deficiency in the safety raw water systems. When the number of water quality violation was compared to the other O&M deficiencies, it was discovered that water quality violations account for roughly 15% of the system's deficiencies. The pumps were substantial contributors to the deficit. Pump availability was predicted and optimized with real time data using response surface method. The prediction model was significant with r-squared value of 0.98. This prediction model can be used to predict forth coming pump failures in nuclear plant.

수도권 팔당취수장 원수 이용 온도차에너지 부존량 조사 (Evaluation of Water Temperature Difference Energy of the Raw Water from Paldang Water Intake Station)

  • 조용;박진훈;김영준;박태진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.170.2-170.2
    • /
    • 2010
  • The amount of the heating and cooling energy of water source heat pump using the raw water from the Paldang water intake station is investigated in the study. The Han river water is conveyed in the large-size shallowly buried pipe. Averaged water temperature at the position, 27 km from the Paldang water intake station, is increased by $1.11^{\circ}C$ due to the geothermal energy transfer under the ground, therefore the raw water has more thermal energy than the river water. To estimate of the thermal energy for the raw water, it is assumed that the water source heat pump is used for the heating and cooling ventilation. When $5.0^{\circ}C$ temperature difference energy of the raw water is used in the heat pump system all the year except for the January and February in which $3.0^{\circ}C$ temperature difference energy is used. It is predicted that total 5,766.3 Tcal could be used in the metropolitan area a year, which is about 3.0% of the river water unutilized energy resources.

  • PDF

플런저 펌프 설계 및 성능시험 (The Optimal Design and Performance Test of Plunger Pump)

  • 김동수;서현석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.840-843
    • /
    • 2003
  • The Paper presents theoretical and experimental investigation of plunger type water hydraulic pump (plunger pump). An analysis of Crank shaft for plunger pump is carried out. With this results, the optimal dimensions of plunger pump are determined. And performance test results about slide resistance, hydraulic leak test, efficiency-pressure. and flow-speed and flow-pressure are presented.

  • PDF

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.26-31
    • /
    • 2002
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of High Vibration of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.197-202
    • /
    • 2001
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbed the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often get troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-weight balanced representatively or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly that the impeller is installed in the shaft. After clearing the trouble, the high vibration is released and the pump is operated with smooth. In this paper the trouble solution of secondary cooling pump is described including the reason of high vibration.

  • PDF

원심펌프 관로계에 대한 임펄스 응답법 적용 연구 (Impulse response method for a centrifugal pump in pipeline systems)

  • 허지성;김현준;송용석;김상현
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.481-489
    • /
    • 2016
  • Method of characteristic(MOC) has been widely used as a transient analysis technique for pressurized pipeline systems. There are substantial studies using MOC for the water hammer triggered through instantaneous valve closures, pump stoppage and pump startup for pipelines systems equipped with a centrifugal pump. Considering restrictions of MOC associated with courant number condition for complicated pipeline systems, an impulse response method(IRM) was developed in the frequency domain. this study implements the impact of centrifugal pump using transfer function in frequency domain approach. Using pump performance curve and the affinity law, this study formulated transfer functions which relate complex pressure head at upstream of pump system to that of downstream location. Simulations of simple reservoir-pump-valve system using IRM with formulated transfer function were similar to those obtained through MOC.

공기열원 히트펌프의 난방 성능특성에 관한 실험적 연구 (Experimental Study on Heating Performance Characteristics of Air Source Heat Pump with Air to Water Type)

  • 이권재;권영철;전종균;박삼진;권정태;허철
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.400-405
    • /
    • 2011
  • This paper presents the heating performance characteristics of the air source heat pump with air to water type. The heating capacity, COP, P-h diagram were measured at various operating conditions, air-side temperatures, relative humidities, and inlet/outlet water temperature under the standard heating condition of KS B 6275. The experimental data for the heat pump were measured using the air-enthalpy calorimeter and the constant temperature water bath. As the air-side temperature increases, the heating capacity and COP increase. The effect of the air-side relative humidities on the heat pump performance is insignificant. The heat pump performance on inlet and outlet water temperatures and air-side temperatures(-7, -11, $-15^{\circ}C$) were studied. Heating capacity and COP increased about 27~39% with the air-side temperature increasing. Enthalpy between the front and the rear of condenser decreased about 6% by increasing of the inlet water temperature. These results can be utilized in the design of the air source heat pump system with air to water type.

PERFORMANCE EVALUATION OF BUBBLE PUMP USED IN A PASSIVE SOLAR WATER HEATER SYSTEM

  • ;박기태;정한식;정효민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2309-2314
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and flow-rates at various locations. The theory analysis of design bubble pump has been given and the experiment design has been included in the paper.

  • PDF

Study on the Performance Characteristics of Centrifugal Pump with Drag-reducing Surfactant Additives

  • Wang, Lu;Li, Feng-Chen;Dong, Yong;Cai, Wei-Hua;Su, Wen-Tao
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권2호
    • /
    • pp.223-228
    • /
    • 2011
  • The performance characteristics of centrifugal pump were measured experimentally when running with tap water and drag-reducing surfactant (Octadecyl dimethyl amine oxide (OB-8)) solutions. Tests have been performed on five cases of surfactant solutions with different concentrations (0ppm (tap water), 200ppm, 500ppm, 900ppm and 1500ppm) and four different rotating speeds of pump (1500rpm, 2000rpm, 2500rpm and 2900rpm). Compared with tap water case, the experimental results show that the total pump heads for surfactant solution cases are higher. And the pump efficiency with surfactant solutions also increases, but the shaft power for surfactant solutions cases decreases compared to t hat for tap water. There exists an optimal temperature for surfactant solutions, which maximizes the pump efficiency.

이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석 (Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger)

  • 한도영;박관준
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF