• 제목/요약/키워드: Water pump

검색결과 1,494건 처리시간 0.035초

강변여과수 열원 히트펌프 온실난방 성능시험 (Estimation of Greenhouse Heating performance for Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;권진경;강연구;이수장
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2011
  • This study was carried out in order to estimate the greenhouse performance for Ground filtration water source heat pump which was installed for supplying the heat to the paprika greenhouse in Jinju city. Experimental area of Greenhouse was $3,300m^2$, For keeping the heat from greenhouse, single plastic covering and double thermal screen was installed. With considering all of greenhouse insulation condition and designed heatng temperature, heating capacity for experimental greenhouse was calculated as 320,000kcal/hr. Coefficient of performance(COP) of Ground filtration water source heat pump was gauged and greenhouse heating performance was tested from Febuary 1 to Febuary 28 in 2011. The result showed that COP of heat pump was in the range of 3.7~4.7 and COP of heating system was in the range of 3.0~3.5. The vaule of COP was very high and the temperature inside greenhouse was well corresponded to the setting temperature of greenhouse environment controlling system. lots of Ground filtration water made the the number of well fewer and the expense for installing heating system cheaper than that of geothermal system used custmarily. and this system went beyond the limitation of intaking amount of groundwater in normal Groundwater source heat pump.

  • PDF

동특성 시뮬레이션을 이용한 공기, 지열 및 지하 저수조 열원 소형 열펌프의 경제성 분석 (Economical Analysis of a Small Capacity Heat Pump utilizing Heat Sources of Air, Geothermal and Underground Water Tank using Dynamic Simulation)

  • 양철호;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 2012
  • Due to reinforcement of international environment regulation and high oil prices, interest in renewable energy is growing. Countries participating in UNFCCC are continuously putting efforts in reducing greenhouse gas after enforcing Kyoto Protocol into effect on Feb, 2005. Energy used in buildings, which relies heavily on fossil fuel accounts for about 24% of total energy consumption. In this study, air, geothermal and water source heat pump systems for an 322 $m^2$ auditorium in an office building is simulated using TRNSYS version 17 for comparing energy consumptions. The results show that energy consumptions of air, geothermal and water source heat pumps are 14,485, 10,249, and 10,405 kWh, respectively. Annual equal payments which consider both initial and running costs become 5,734,521, 6,403,257 and 5,596,058 Won. Thus, water source heat pump is the best economical choice.

발전소 순환수 및 복수 계통 케이블 건전성 평가 (Cables Condition Assessment for Circulating Water Pump & Condenser Extraction Pump)

  • 하체웅;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.614-615
    • /
    • 2007
  • There are roughly a hundred types of cables in power plants. The distribution of circuits in a nuclear plant is comprised of 20% instrument cables, 61% control cables, 13% AC power cables, 1% DC power cables, and 5% communication lines. In the nuclear power plant, medium voltage cables are generally included in the scope of systems reviewed for safety and are included in a plant's maintenance program. Medium voltage cables provide power to many critical components in plants, including feed water pumps, circulating water pumps, and condensate pumps. Among these cables, high temperature sections of cables feeding electrical power to the circulating water pump and the condenser extraction pump were found. The evaluation for these cables is performed to find the maximum allowable current and temperature. The result shows that the load current flowed about 85% of the allowable current ampacity, and the temperature of conductor at full load current did not exceed the limited temperature. Therefore, existing cables for circulating water pump and condenser extraction pump system are going to be used during design life.

  • PDF

태양열 온수기 시스템에 적용된 기포펌프의 성능평가에 대한 연구 (A Study on Performance Analysis of the Bubble Pump in Solar Water Heater System)

  • 이광성;이설송;김진화;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2310-2315
    • /
    • 2008
  • In this paper, study on performance analysis of bubble pump on the domestic solar water heater system is presented. Device of this experiment is consisted of bubble pump, solar collector and heat exchanger. At the mean time, this system have attached temperature sensors and pressure sensors at bubble pump. In addition, the flow meter was installed at outlet of heat exchanger. And then result of experimental study, average value of the heat exchange amount in heat exchanger was about 7.9kcal/hr, the maximum value of the heat amount in water tank($0.4m^3$) was 489.7kcal/hr and the maximum value of the mass flow rate in bubble pump was about $0.5{\ell}/min$.

  • PDF

엔진 냉각 시스템 개선에 관한 실험적 연구 (An Experimental Study on Engine Cooling System Improvement)

  • 전문수;황용하
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.77-82
    • /
    • 2004
  • This paper describes the improvement of engine cooling system. To improve engine cooling performance, the authors approached in two ways. One is to increase water pump performance, changing of impeller shape and lightening of material were carried out. The second one is cooling efficiency rise, which were investigated with head gasket coolant flow passage optimization with flow visualization technique. The test results show that water pump performance was increased effectively, reduction of pump drive torque, and increase of pump flow-rate and pressure rise. Gasket hole pattern optimization test results represent an optimized head coolant flow which stands cross flow from exhaust to intake port side and small vortex were removed.

  • PDF

고점성용 펌프의 성능해석 (Pump Performance Analyses with High Viscosity Fluids)

  • 노형운;서상호;김동주
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.367-370
    • /
    • 2003
  • In this study the effects of fluid viscosity on the pump performances of a conventional centrifugal pump were experimentally studied. The study aimed to compare the pump characteristics for water and high viscosity fluids. The Working fluids are water, aqueous sugar solution and glycerin solution. The pump characteristics of total head and efficiency with high viscosity fluids were different. The performance curves of efficiency for the sugar and glycerin solutions were decreased up to 8.1% and 12.9% than that of water.

  • PDF

응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리 (The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank)

  • 김동하;이수영;정의택
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

상수도의 저용해성 액체 정량투입 방안 연구 (A Study on the Correct injection method for low dissolution liquid in the Water Treatment Plant)

  • 김진훈;박종호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.273-277
    • /
    • 2005
  • The large particles of suspended matter in raw water can be removed by allowing them to settle out in a presedimentation basin. But there are smaller particles in almost all surface water and some groundwater that will not settle out within a reasonable time without some help to accelerate the process, In the coagulation and flocculation processes, nonsettleable solids are converted into large and heavier settleable solids by physical-chemical changes broght about by adding and mixing coagulant chemicals into the raw water. The object of this research was to improve corrective injection method for low dissolution liquid in the water treatment plant. A sort of chemical feed equipment are diaphram pump, flow control in combined magnetic flowmeter md control valve, roto dipper wheel system and tube pump. Particularly low dissolution liquid (Calcium Hydroxide) put in a bit by feed equipment, tube pump is very useful method for corrective injection method in the water treatment plant.

  • PDF

열펌프 가열식 온수기의 동적특성 해석 (Numerical Simulation on Dynamic Characteristics of a Water Heater System Driven by a Heat Pump)

  • 김민성;김민수;백남춘
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.10-20
    • /
    • 2002
  • A dynamic model of a water heater system heated by a heat pump was developed. The water heater system was composed of heat pump and hot water reservoirs. Finite volume method (FVM) was applied to describe the heat exchangers. A new constraint on electronic expansion valve (EEV) or thermostatic expansion valve (TXV) that can control superheat after the evaporator was developed. Dynamic performances were evaluated for various sizes of the reservoir. In order to compare those performances, time scale was normalized by time constant representing the characteristics of reservoir size. Time constant was determined from quasi steady-state simulation of the system. From the simulation, the size of the water heater reservoir was found to have a large influence on the transient performance of the sys- tem. Therefore, the optimization of the reservoir size is needed in a design process.

Performance Analysis of Water-Water Heat Pump System of 100 kW Scale for Cooling Agricultural Facilities

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Biosystems Engineering
    • /
    • 제39권1호
    • /
    • pp.34-38
    • /
    • 2014
  • Purpose: In this study, the performance of cooling system with the water-water heat pump system of 100kW scale made for cooling agricultural facilities, especially for horticultural facilities, was analyzed. It was intended to suggest performance criteria and performance improvement for the effective cooling system. Methods: The measuring instruments consisted of two flow meters, a power meter and thermocouples. An ultrasonic and a magnetic flow meter measured the flow rate of the water, which was equivalent to heat transfer fluid. The power meter measured electric power in kW consumed by the heat pump system. T-type thermocouples measured the temperature of each part of the heat pump system. All of measuring instruments were connected to the recorder to store all the data. Results: When the water temperature supplied into the evaporator of the heat pump system was over $20^{\circ}C$, the cooling Coefficient Of Performance(COP) of the system was higher than 3.0. As the water temperature supplied into the evaporator, gradually, lowered, the cooling COP, also, decreased, linearly. Especially, when the water temperature supplied into the evaporator was lower than $15^{\circ}C$, the cooling COP was lower below 2.5. Conclusions: In order to maintain the cooling COP higher than 3.0, we suggest that the water temperature supplied into evaporator from the thermal storage tank should be maintained above $20^{\circ}C$. Also, stratification in the thermal storage tank should be formed well and the circulating pumps and the pipe lines should be arranged in order for the relative low-temperature water to be stored in the lower part of the thermal storage tank.