• Title/Summary/Keyword: Water plasma

Search Result 1,265, Processing Time 0.035 seconds

Improvement of Gas Dissolution Rate using Air Atomizing Nozzle (이류체 노즐을 이용한 가스의 용존율 향상)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.27 no.3
    • /
    • pp.219-225
    • /
    • 2018
  • This study was conducted to investigate the possibility of utilizing various types of nozzles and gas-liquid mixers to increase the dissolution rate of plasma gas containing ozone generated in a dielectric barrier plasma reactor. After selecting the air atomizing nozzle with the highest gas dissolution rate among the 13 types of test equipment, we investigated the influence of the operating factors on the air atomizing nozzle to determine the optimal plasma gas dissolution method. The gas dissolution rate was measured by a simple and indirect method, specifically, the measurement of KLa instead of direct measurement of ozone concentration, which requires a longer analysis time. The results showed that the KLa value of the simple mix of air and water was $0.372min^{-1}$, Which is 1.44 times higher than that ($0.258min^{-1}$) of gas emitted from a normal diffuser. Among the nozzles of the same type, the KLa value was highest for the nozzle having the smallest orifice diameter. Among the 13 types of devices tested, the nozzle with highest KLa value was the M22M nozzle, which is a gas-liquid spray nozzle. The relationship between water circulation flow rate and KLa value in the experimental range was linear. The air supply flow rate and KLa value showed a parabolic-type correlation, while the optimum air supply flow rate for the water circulation flow rate of 1.8 L / min is 1.38 times.

Physicochemical Properties, Stabilities and Pharmacokinetics of Cephalosporin 3'-Quinolone Dithiocarbamate (세팔로스포린 3'-퀴놀론의 물리화학적 성질, 안정성 및 체내약물동태)

  • 나성범;공재양;김완주;지웅길
    • YAKHAK HOEJI
    • /
    • v.37 no.6
    • /
    • pp.638-646
    • /
    • 1993
  • A cepfialosporin with an aminothiazoiylmethoxyimino-type side chain at the 7 position and bicyclic quinolone dithicarbamate at the 3' position was synthesized. It has broad and potent antivacterial activity in vitro. The antibacterial spectrum reflects contributions of both the cephalosporin moiety and the quinolone moiety. Thus, this compound was named DACD implying a dualaction cephalosporin derivative. In this paper, the physicochemical proper-ties (lipid-water partition, pKa), stability and pharmacokinetics of DACD were determined and compared with cefotaxime 3'-norfloxacin dithiocarbamate (CENO). Stability tests were studied in pH 1.20, 6.80 and 8.00 buffers and in the presence of AB type human plasma, rat liver homogenate and its .betha.-lactamase. The pharmacokinetic parameters of DACD were evaluated in mice after a single intravenous dose of 40 mg/kg. The results are as follows. The lipid-water partition coefficient of DACD was higher than that of CENO. The calculated pKa values of CENO and DACD, were 6.82$\pm$0.03, 7.53$\pm$0.21, respectively. In the hydrolysis test, half-lives (t$^{1/2}$) of CENO and DACD was 66.0 hr and 80.0 hr in pH 6.80 buffer, 190 hr and 91.4 hr in pH 8.00 buffer. CENO and DACD were rapidly hydrolyzed in human plasma and in rat liver hornogenate. Half-lives (t$_{1/2}$ of CENO and DACD were 1.29 hr and 1.15 hr in hyman plasma, 0.62 hr and 0.71 hr rat liver homogenate. In $\beta$-lactamase stability test, CENO and DACD were very stable to the .betha.-lactamases obtained from three different strains. Half-life (t$_{1/2}$) and areas under the curve (AUC) in mice were 2.33 hr and 15.97 (mg.h/1), respectively.

  • PDF

POLYMER SURFACE MODIFICATION WITH PLASMA SOURCE ION IMPLANTATION TECHNIQUE

  • Han, Seung-Hee;Lee, Yeon-Hee;Lee, Jung-Hye;Yoon, Jung-Hyeon;Kim, Hai-Dong;Kim, Gon-ho;Kim, GunWoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.345-349
    • /
    • 1996
  • The wetting property of polymer surfaces is very important for practical applications. Plasma source ion implantation technique was used to improve the wetting properties of polymer surfaces. Poly(ethylene terephtalate) and other polymer sheets were mounted on the target stage and an RF plasma was generated by means of an antenna located inside the vacuum chamber. High voltage pulses of up to -10kV, 10 $\mu$sec, and up to 1 kHz were applied to the stage. The samples were implanted for 5 minutes with using Ar, $N_2,O_2,CH_4,CF_4$ and their mixture as source gases. A contact angle meter was used to measure the water contact angles of the implanted samples and of the samples stored in ambient conditions after implantation. The modified surfaces were analysed with Time-Of-Flight Mass Spectrometer (TOF-SIMS) and Auger Electron Spectroscopy (AES). The oxygen-implanted samples showed extremely low water contact angles of $3^{\circ}C$ compared to $79^{\circ}C$ of unimplanted ones. Furthermore, the modified surfaces were relatively stable with respect to aging in ambient conditions, which is one of the major concerns of the other surface treatment techniques. From TOF-SIMS analysis it was found that oxygen-containing functional groups had been formed on the implanted surfaces. On the other hand, the $CF_4$-implanted samples turned out to be more hydro-phobic than unimplanted ones, giving water contact angles exceeding $100^{\circ}C$ . The experiment showed that plasma source ion implantation is a very promising technique for polymer surface modification especially for large area treatment.

  • PDF

Fundamental study of electrolyte cathode atomic discharge for development of on-line monitoring system (On-line monitoring system 개발에 관한 음극 액상 글로우 방전의 기초 연구)

  • Kim, Kyung-Mi;Woo, Young-A;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.496-501
    • /
    • 2002
  • The electrolyte cathode glow discharge (ELCAD) is a new optical system for direct determination of trace heavy metals in flowing water. ELCAD has been successfully developed for on-line monitoring of heavy metals in flowing water. The application of an atmospheric glow discharge between an electrolyte solution cathode and a platinum rod anode led to the development of stable discharge. The fundamental aspects of new plasma source have been investigated. The fundamental study of ELCAD system has been measured plasma temperature using Einstein-Boltzmann equation after searching Fe atomic emission lines. The spectrum of each elements such as Cu, Pb, Fe, Ni and Cr show only major elemental line and no ionic line possibly due to low temperature plasma source. The detection limits of each elements are also investigated. These informations show that this type of plasma may apply for monitoring of heavy metals in waste water which consists of complex matrix.

The development of the discharge reactor for water purification and a spectroscopic study on its discharge emission (수처리용 방전 리액터의 개발과 방전 발광의 분광학적 분석 연구)

  • Han, Sang-Bo;Park, Jae-Youn;Kim, Jong-Seog;Jung, Jang-Gun;Koh, Hee-Seog;Park, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.581-582
    • /
    • 2005
  • In order to apply the discharge plasma processing. to industrial areas, the control of the chemical reaction mechanism is necessary. The hybrid plasma reactor was designed for the effective treatment of wastewater and hazardous volatile organic substances. This plasma reactor was similar to the barrier discharge, and surface discharge on the dielectric surface was propagated to the water surface strongly for the heterogeneous chemical reaction at the interface between the working gas and the water surface. The discharge emission in this discharge reactor was mainly $N_2$ second positive band in the case of $N_2$ or air gas atmosphere, and intensities from OH radicals in Ar gas atmosphere were stronger than in $N_2$ or air gas atmosphere. From this result, it is necessary to apply Ar gas for the effective generation of OH radicals in this plasma reactor.

  • PDF

Effect of Acclimation Methods on Physiological Status of Pacific White Shrimp Litopenaeus vannamei Bred in Low Salinity Biofloc (저염분 바이오플락에서 사육한 흰다리새우(Litopenaeus vannamei)의 해수 순치방법에 따른 혈장성분 및 혈장삼투압 비교)

  • Jeon, Yu-Hyeon;Lee, Jong-Min;Kim, Su Kyung;Kim, Su-Kyoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.761-768
    • /
    • 2021
  • This study was carried out to identify an effective method to acclimate low-salinity (4 psu) bred Litopenaeus vannamei (mean body weight 16±3.3 g) to sea water. The fast acclimation group (FA) was directly exposed to filtered sea water (32 psu) while the slow acclimation group (SA) was exposed to a slow increase in salinity. Shrimps were sampled at 0, 1, 3, 6, 12, 24 and 48 h for plasma analyses. The plasma components between experimental groups did not show significant differences. The hemolymph osmolality (HO) in FA increased significantly after 1 h (P<0.05), while in SA it started to increase slowly only at 24 h and reached a similar level to that of FA at 48 h. The levels of Na+ and Mg2+ ions were significantly different between the two treatments (P<0.05), but there was no significant difference in Ca2+ ion levels. We found that the different methods of acclimation of L. vannamei to sea water do not affect the plasma components significantly, but lead to changes in the HO and ion levels, it is considerable to acclimate gradually for at least two days.

Effect of the magnetized water supplementation on blood glucose, lymphocyte DNA damage, antioxidant status, and lipid profiles in STZ-induced rats

  • Lee, Hye-Jin;Kang, Myung-Hee
    • Nutrition Research and Practice
    • /
    • v.7 no.1
    • /
    • pp.34-42
    • /
    • 2013
  • This study investigated the effects of magnetized water supplementation on blood glucose, DNA damage, antioxidant status, and lipid profiles in streptozotocin (STZ)-induced diabetic rats. There were three groups of 4-week-old male Sprague-Dawley rats used in the study: control group (normal control group without diabetes); diabetes group (STZ-induced diabetes control); and magnetized water group (magnetized water supplemented after the induction of diabetes using STZ). Before initiating the study, diabetes was confirmed by measuring fasting blood glucose (FBS > 200 dl), and the magnetized water group received magnetized water for 8 weeks instead of general water. After 8 weeks, rats were sacrificed to measure the fasting blood glucose, insulin concentration, glycated hemoglobin level, degree of DNA damage, antioxidant status, and lipid profiles. From the fourth week of magnetized water supplementation, blood glucose was decreased in the magnetized water group compared to the diabetes group, and such effect continued to the 8th week. The glycated hemoglobin content in the blood was increased in the diabetes group compared to the control group, but decreased significantly in the magnetized water group. However, decreased plasma insulin level due to induced diabetes was not increased by magnetized water supplementation. Increased blood and liver DNA damages in diabetes rats did significantly decrease after the administration of magnetized water. In addition, antioxidant enzyme activities and plasma lipid profiles were not different among the three groups. In conclusion, the supplementation of magnetized water not only decreased the blood glucose and glycated hemoglobin levels but also reduced blood and liver DNA damages in STZ-induced diabetic rats. From the above results, it is suggested that the long-term intake of the magnetized water over 8 weeks may be beneficial in both prevention and treatment of complications in diabetic patients.

Measurement of Plasma Parameters (Te and Ne) and Reactive Oxygen Species in Nonthermal Bioplasma Operating at Atmospheric Pressure

  • Choi, Eun Ha;Kim, Yong Hee;Kwon, Gi Chung;Choi, Jin Joo;Cho, Guang Sup;Uhm, Han Sup;Kim, Doyoung;Han, Yong Gyu;Suanpoot, Pradoong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.141-141
    • /
    • 2013
  • We have generated the needle-typed nonthermal plasma jet by using an Ar gas flow at atmospheric pressure. Diagnostics of electron temperature anddensity is critical factors in optimization of the atmospheric plasma jet source in accordance with the gas flow rate. We have investigated the electron temperature and density of plasma jet by selecting the four metastable Ar emission lines based on the atmospheric collisional radiative model and radial profile characteristics of current density, respectively. The averaged electron temperature and electron density for this plasma jet are found to be ~1.6 eV and ~$3.2{\times}10^{12}cm^{-3}$, respectively, in this experiment. The densities of OH radical species inside the various bio-solutions are found to be higher by about 4~9 times than those on the surface when the argon bioplasma jet has been bombarded onto the bio-solution surface. The densities of the OH radicalspecies inside the DI water, DMEM, and PBS are measured to be about $4.3{\times}10^{16}cm^{-3}$, $2.2{\times}10^{16}cm^{-3}$, and $2.1{\times}10^{16}cm^{-3}$, respectively, at 2 mm downstream from the surface under optimized Ar gas flow 250 sccm.

  • PDF

Formation of Barrier ribs for PDP by Water Jet Etching of Green Tape

  • Cho, Yu-Jeong;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.784-787
    • /
    • 2003
  • In this study, water jet etching of aqueous green tape was attempted for processing barrier rib of plasma display panel. This process combines 1) chemical etching between water and aqueous based binder in the tape and 2) mechanical erosion by water jet. Effects of etching parameters such as pressure, temperature and aqueous binder content on the morphology of barrier ribs formed were investigated. The results demonstrated a possibility of processing barrier ribs by water jet etching.

  • PDF

Simplified HPLC Method for the Determination of Prazosin in Human Plasma and Its Application to Single-dose Pharmacokinetics

  • Gwak, Hye-Sun;Chun, In-Koo
    • Biomolecules & Therapeutics
    • /
    • v.13 no.2
    • /
    • pp.90-94
    • /
    • 2005
  • Prazosin hydrochloride is an antihypertensive drug with selective ${\alpha}_1$-adrenoreceptor blocking effects. A simple high performance liquid chromatographic method has been developed and validated for the quantitative determination of prazosin in human plasma. A reversed-phase C18 column was used for the separation of prazosin and terazosin (internal standard) with a mobile phase composed of water, acetonitrile and triethylamine(75:25:0.1, V/V;pH5.0) at a flow rate of 1.5 ml/min. the fluorescence detector was set at excitation and emissionwavelengths of 250 and 370 nm, respectively. Intra-and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification of 0.5 ng/ml. Good recovery (>80%) was seen in plasma. Prazosin was stable in human plasma under various storage conditions. This method was used successfully for a pharmacokinetic study in plasma after oral administration of a single 2-mg dose as prazosin base to 16 healthy volunteers. The maximum plasma concentration of prazosin was 23.1 ${\pm}$ 16.5 ng/ml at 2.1 h, and the mean area under the curve and elimination half-life were calculated to be 108.4 ${\pm}$ 74.2 ng ${\cdot}$hr/ml and 2.5 ${\pm}$ 0.6 h, respectively.