• 제목/요약/키워드: Water pH

검색결과 8,444건 처리시간 0.036초

갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상 (Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons)

  • 가길현;김윤용;이준호;안치화;한인섭;민병대
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

이온수기 필터(pH)의 안정화 성능평가 (Stabilization Performance Evaluation of Filter(pH) Using Ionic Water Generator)

  • 남상엽;권윤중
    • 전자공학회논문지
    • /
    • 제52권3호
    • /
    • pp.199-205
    • /
    • 2015
  • 본 연구는 이온수기의 필터에 관련된 것으로 요즘 건강에 많은 관심을 가지고 있는 물은 그 종류도 매우 다양하다. 그 중에서 이온 수기는 의료기기로 분류되어 식약청에서 승인을 거친 후 제조할 수 있고, 기능을 가지고 있는 물을 만드는 시스템이다. 이온 수기는 기본적으로 저장되고 포장된 물이 아니며 이온 수기는 수도나 지하수에 직접 연결되어 여러 가지 필터를 통해 깨끗하게 정수된 pH7~7.5의 중성수를 격막을 이용하여 전기 분해하면 물속에 있는 음이온과 양이온을 격막을 통해서 -전극 쪽에는 칼슘($Ca^+$), 칼륨($K^+$), 마그네슘($Mg^+$), 나트륨($Na^+$)을 포함한 물로 인체에 유익한 미네랄이 포함된 알칼리이온수를 얻을 수 있다. 일반적으로 이온수기에서 전기분해의 전압의 크기를 조절하여 Ph농도를 5~9까지 변화를 주어 사용한다. 통상1단(pH8), 2단(pH8.5), 3단(pH9), 4단(pH9.5)으로 알칼리 이온 수에 사용되고 -1단(pH6.0), -2단(pH5.0)의 산성이온수로 사용하고 있다. 그런데 초기 필터의 상태를 확인해 보면 직수에서 필터를 통과한 정수상태에서 물은 약알칼리로 출수된다는 것이 큰 문제이다. 따라서 초기에 설정된 이온수의 pH값은 필터가 안정화된 후 값은 전혀 틀린 값이 나온다는 것을 확인하였다. 즉 초기에 설정된 이온수기의 pH 값은 사용 중 크게 변화하여 참값이 될 수 없음을 규명하였다. 이 문제를 해결하기 위해서는 필터를 일정시간 통수 세척을 해서 사용하거나 필터의 초기 산성화 처리를 해서 중성화하여야 할 것으로 판단된다.

폴리염화알루미늄 과량주입에 의한 고(高) pH 원수의 수처리효율 개선 (Improvement of Water Treatment Efficiency by Poly Aluminum Chloride Overdosing in High pH Raw Water)

  • 임재철;김진근
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.39-46
    • /
    • 2009
  • A method to improve water treatment efficiency by coagulant overdosing for high pH raw water at a drinking water treatment plant (WTP) which had no pH adjusting facilities was investigated. Poly aluminum chloride (PACl) was used for coagulant, and turbidity removal efficiency was evaluated as a function of PACl dosage increases. pH and turbidity of supernatant of jar-tester were 7.10 and 0.50 NTU respectively, when the turbidity, pH, alkalinity, water temperature, conductivity of raw water were 1.75 NTU, 9.38, 46.5 mg/L, $6.4^{\circ}C$, $400{\mu}s/cm$, respectively. Turbidity of settled water was reduced from 2.18 NTU to 0.28 NTU (87% reduction) when PACl dosage was increased from 16 mg/L to 45 mg/L at a full scale WTP. This can be attributed to the recovery of coagulant efficiency by pH reduction with the increase of coagulant dose, however coagulation efficiency was reduced with the formation of Al(OH)4- by PACl addition at higher pH. Coagulant overdosing was proven to be a rapid and effective method for high pH raw water, which can be applied at drinking WTP.

CO2 주입에 의한 pH 조정이 정수장 응집효율 및 알루미늄 용출에 미치는 영향 (Effect of pH Adjustment by CO2 on Coagulation and Aluminum Elution in Water Treatment)

  • 이길성;김민채;권재국;서규태
    • 대한환경공학회지
    • /
    • 제35권1호
    • /
    • pp.17-22
    • /
    • 2013
  • 본 연구는 조류 개체 수 증가로 pH가 급격하게 상승한 원수가 정수장으로 유입될 때 pH 조정을 위해 사용하는 이산화탄소($CO_2$) 주입이 응집효율 및 용존 알루미늄 농도변화에 미치는 영향을 고찰하였다. 응집제 1 mg/L에 주입에 따른 pH 감소는 LAS -0.0384, PAC -0.0254, A-PAC -0.0201, PACS2 -0.0135로 나타났다. 용존 알루미늄 농도는 pH 7.44에서 0.02 mg/L, pH 7.96에서 0.07 mg/L, pH 8.16에서 0.12 mg/L, pH 8.38에서 0.39 mg/L로 응집공정의 pH 증가에 따라 용존 알루미늄 농도가 증가하는 것으로 나타났다. 여기서 주목할 점은 급속 교반 후 pH 8.0을 초과할 때부터 용존 알루미늄 농도는 급격하게 증가하는 것이다. 그러므로 높은 pH의 원수가 유입되는 정수장에서 알루미늄 농도가 먹는 물 수질 기준 만족하기 위해서는 응집공정의 pH가 7.8 이하로 유지되도록 공정관리가 필요하며, 원수 pH가 8.0 이상 유입되는 경우 이산화탄소($CO_2$) 주입으로 pH를 7.3 내외로 일정하게 유지할 수 있었다. 또한 이산화탄소($CO_2$) 주입으로 응집공정에서 pH를 조정함으로써 탁도 및 응집제 절감, 용존 알루미늄 농도 감소 효과를 확인할 수 있었다.

관개용수 pH가 벼 생육, 수량, 미질에 미치는 영향(I) (Effect of pH in Irrigation Water on the Growth, Yield, and Grain Quality of Rice)

  • 최선화;김호일;안열;허유만
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.551-554
    • /
    • 2003
  • This study was carried out to investigate the effects of the pH of irrigation water on the growth, yield, and grain quality of rice. It acquire fundamental knowledges to set up irrigation water quality standards. The pot experiment was conducted with 5 treatments using irrigation waters with various pH values(control, 4, 6, 8, 10) and replicated four times with randomized block design. The results of this study showed that the uptake of N, P, and K, Ripened grain ratio and yield of rice tended to be reduced at the irrigation water of pH 4 and pH 10. P uptake, Ripened grain ratio and yield of rice at pH 4 water were significantly lower than the control. K uptake at pH 10 water was significantly lower than the control. Plant height, SPAD value and protein content of rice were not affected by the pH of irrigation water.

  • PDF

물과 토양에서 인의 농도, 탁도 그리고 pH와의 관계에 관한 연구 (A study on the relationship between concentration of phosphorus, turbidity, and pH in water and soil)

  • 민영홍;현대용;음철헌;이승호
    • 분석과학
    • /
    • 제24권4호
    • /
    • pp.304-309
    • /
    • 2011
  • 본 연구는 물과 토양에서 pH와 상등액을 변화 시켜었을 때 인과 탁도의 행태에 관해 연구 하였다. 탁도의 인 용출율은 pH 4 이하 또는 pH 7 이상일 때 증가 되었고, 토양으로 부터 탁도 발생율은 pH가 증가하면 증가하며, pH 4 보다 커지면 급격히 상승한 후 pH 6 이상에서 안정화된다. 용존성인은 2-24시간까지 증가 후 안정화 됐고, 탁도 역시 24 시간까지 정점에 도달한 후 96시간까지 감소됨. 시료상 등수를 교체를 하면 용존성인과 탁도는 감소한다. 시료를 pH 6에서 pH 10으로 증가시키고, 상등액 교체를 1회에서 4회로 동시에 증가시킬 때 용존성인과 탁도의 행태는 유사하다. 이 결과로 용존성인과 탁도는 pH와 직접적인 연관이 있다고 사료되며, 호수는 pH 7-10 정도이기 때문에 이 결과는 대단히 중요하다.

원수 pH 조정에 의한 정수 수질 개선 (Improvement of Quality in Treated Water by the pH Adjustment of Raw Water)

  • 정관조;이경우;김현희;정의선;박현;한선희
    • 대한환경공학회지
    • /
    • 제32권5호
    • /
    • pp.469-476
    • /
    • 2010
  • 상수원수의 특성 변화와 갈수기 조류 발생으로 인한 원수 pH 상승 시기에 이산화탄소($CO_2$)를 주입하여 원수 pH를 조정함으로써 혼화·응집지의 응집 효율을 향상시켜 생산 정수 중의 잔류알루미늄, 탁도, 입자수 등의 농도를 낮추는 방법을 조사하고자 본 연구를 실시하였다. 원수 pH 8.0 이상이며 밤 낮의 pH 변화가 크지 않은 2월, 3월, 4월, 12월 중에 이산화탄소 주입 전 후의 정수 수질 변화를 고찰하였으며, 정수처리 공정수를 대상으로 정수 수질평가와 밀접한 관련이 있는 알루미늄, 탁도, 입자수, TOC, THMs, 2-MIB, geosmin 등의 농도 변화를 조사하였다. 조사결과, 혼화 응집지의 응집 효율 향상으로 입자수, 탁도, 알루미늄과 같은 입자성 물질과 무기물질은 감소하였으며 서울시 정수 목표수질값인 입자수 30개/mL 이하, 탁도 0.05 NTU 이하, 알루미늄 0.02 mg/L 이하의 양호한 정수 수질을 유지하기 위해서는 원수 pH 상승시기 이산화탄소를 주입하여 착수정원수 pH를 7.4 이하로 유지해야 하는 것으로 나타났다. 또한 THMs, CH, HAAs, HANs 등 소독부산물과 이취미 유발물질인 2-MIB, geosmin 농도는 원수 pH 변화와 무관함을 알 수 있었으며, 특히 이취미 유발물질인 2-MIB, geosmin는 pH 변화보다는 원수 중의 2-MIB, geosmin 농도가 정수 중의 농도 결정에 주요한 영향을 주는 것으로 나타났다.

유전체구 충진형 전극계의 코로나방전과 강전해수 발생특성 (Corona Discharge and Strong Electrolyzed Water Generation Characteristics of the Electrode System Bedded by Dielectric Pellets)

  • 김진규
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.46-54
    • /
    • 2002
  • 본 논문은 전해수 발생장치내에 이온분리집속 격막을 설치하여 비유전율이 틀리는 유전체구를 충진한 구조로 함으로써 고효율의 강전해수 발생장치를 제안하였다. 염화나트륨이 용해된 수도수와 일반수도수를 원료수로서 본 강전해수 발생장치에 인입하였을 때 충진된 유전체구의 비유전율 변화가 수중 이온분리집속성능에 미치는 영향을 연구 검토하였다. 실험결과로서 본 강전해수 발생장치에 원료수로서 수도수의 유속을 0.5[LPM]으로 인입시키고 구형파 펄스전류를 1.0[A]로 인가하였을 때 pH 3.1과 10.6의 전해수를 얻을 수 있었다. 그리고 염화나트륨이 0.1[wt%]용해된 수도수의 경우 pH 2.8과 11.7의 전해수를 얻었다. 또한 비유전율이 가장 높은 BaTiO$_3$과 같은 유전체구를 전해수 발생장치에 충진한 경우 각각 PH 2.7, 11.7과 pH 2.4, 12.0의 전해수를 얻을 수 있었다.

알칼리 환원수 필터의 산화환원전위 안정화 평가 (Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water)

  • 남상엽;권윤중
    • 전자공학회논문지
    • /
    • 제53권8호
    • /
    • pp.129-135
    • /
    • 2016
  • 본 연구는 알칼리 환원수기에 3가지 필터(활성카본, 중공사막, 카본블럭)를 이용해서 원수를 통과시켜 통수 양에 따른 산화환원전위(Oxidation Reduction Potential) ORP값이 안정화되는 것을 평가한 것이다. 알칼리 환원수기는 환원의 기능을 가지고 있는 물을 만드는 시스템으로 인체에 유익한 미네랄과 ORP값이 일반 물에 비해 매우 낮은 값을 가지고 있는 기능수이다. 필터를 통과한 물을 전기 분해하면 물속에 있는 음이온과 양이온은 격막을 통해서 -전극 쪽에는 칼슘($Ca^+$), 칼륨($K^+$), 마그네슘($Mg^+$), 나트륨($Na^+$)을 포함한 물로 인체에 유익한 미네랄이 포함된 알칼리 환원수를 얻고 +극에는 염소(Cl),인(P),유황(S)등 - 이온을 띄고 있는 유기물이 만들어 진다. 실험에서 알칼리 환원수(Alkaline Reduced Water)에서 전기분해의 전압의 크기를 조절하여 1단(pH8), 2단(pH8.5), 3단(pH9), 4단(pH9.5)으로 알칼리 환원수에 사용되고 -1단(pH6.0), -2단(pH5.0)의 산성산화수로 사용하고 있다. 이러한 시스템으로 3가지 필터에 통수하면서 ORP값이 어떻게 변화하고 어느 정도에서 안정화되는지를 평가하였고 대략 100L는 통수되어야 ORP값이 안정화하는 것을 측정하고 평가하였다.

낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가 (Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination)

  • 김상구;손희종;이정규;염훈식;유평종
    • 대한환경공학회지
    • /
    • 제39권4호
    • /
    • pp.201-207
    • /
    • 2017
  • 본 연구에서는 낙동강 하류원수에 대한 응집제 주입율 자동화를 위해 stream current detector (SCD)와 charge analyzing system (CAS)의 적용성 비교 평가하였다. SCD 시스템을 이용한 경우, 원수 pH가 9.3에서 5.7로 낮아지면 pH 9.3에서 설정된 유동 전하값을 응집제 주입율로 사용할 수 없었고, pH 5.7에 맞는 유동 전하값의 재설정이 필요하였다. 원수의 pH 변화에 따른 SCD의 유동 전하값의 재설정을 하지 않을 경우, 후단의 모래여과 처리수 탁도가 증가하는 현상을 보였다. CAS 시스템의 경우는 원수 pH의 범위가 6.0~9.3의 범위일 때 polydadmac을 전하 중화제로 사용하는 것이 가능하였고, 고탁도 원수에도 poly-dadmac이 양호한 전하중화제로 평가되었다. 그러나 pH 5~11의 범위에서 polydadmac의 전하량은 거의 변화하지 않은 반면, 응집제로 사용되는 alum의 전하량은 6배 정도 차이가 발생하고, pH에 적합한 응집제 요구량을 보였다. 따라서 원수의 pH가 높은 경우는 전하 적정제로 정수장에서 사용하는 응집제를 직접 이용하는 것이 효율적이었다.