• Title/Summary/Keyword: Water level detection

Search Result 262, Processing Time 0.027 seconds

Monitoring and Evaluation of Analytical Methods of Perchlorate with IC and LC/MS (IC와 LC-MS를 이용한 퍼클로레이트 분석 방법 비교 및 모니터링)

  • Kim, Hwa-Bin;Sim, Won-Jin;Kim, Min-Young;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • In this study, we tried to establish analysis methods of perchlorate with ion chromatography(IC) and liquid chromatography/mass spectrometry(LC/MS) and monitored perchlorate levels in various kinds of water and soil samples. The obtained method detection limit(MDL) of IC was 1 ppb and that of LC/MS was 0.005 ppb in water sample. We monitored the ground and spring water in Busan and the average perchlorate level in ground water was 0.031 $\pm$ 0.011 ppb and that of spring water was 0.013 $\pm$ 0.014 ppb. Wastewater samples were also examined and the levels of perchlorate ranged from 0.007 to 0.380 ppb. The perchlorate levels in all water samples investigated in this study were below the EPA guideline.

Measurement System for Performance Evaluation of Acoustic Materials in a Small Water Tank (소형수조에서 음향재료의 반향음감소와 투과손실 측정시스템 구성)

  • Shin, Mi-Ru;Cho, Jung-Hong;Lee, Kyung-Teak;Kim, Jea-Soo;Jeon, Jae-Jin;Ham, Il-Bea;Kang, Chang-Gi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • Since the detection probability is critically dependent on the target strength (TS) in active sonar and on the radiated noise level (RNL) in passive sonar, the acoustic materials for echo reduction (ER) and transmission loss (TL) are widely used for the stealth of underwater targets. In this paper, a measurement system based on the small water tank, for the frequency range of greater than 30 kHz, is developed and verified using reference targets. In order to design the water tank and the geometry of test samples, a program is developed to calculate the arrival time of interfering signals due to the reflection from water tank walls and also due to the diffraction from the edge of the test samples. Considering all the interfering signals, an optimal experimental configuration for water tank and test samples is designed and used throughout the experiment. Next, the signal processing algorithms to estimate ER and TL are developed based on the measured propagation loss reflecting the geometric spreading characteristics of the transducer. Finally, a set of reference targets such as aluminium plate and perfectly reflecting plate are used in a small water tank to verify the developed measurement system.

Changes in the Riverbed Landforms Due to the Artificial Regulation of Water Level in the Yeongsan River (인위적인 보 수위조절로 인한 영산강 하도 지형 변화)

  • Lim, Young Shin;Kim, Jin Kwan
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.1
    • /
    • pp.1-19
    • /
    • 2020
  • A river bed which is submerged in water at high flow and becomes part of the river at low flow, serves as a bridge between the river and the land. The channel bar creates a unique ecosystem with vegetation adapted to the particular environment and the water pool forms a wetland that plays a very important role in the environment. To evaluate anthropogenic impacts on the river bed in the Middle Yeongsangang River, the fluvial landforms in the stream channel were analyzed using multi-temporal remotely-sensed images. In the aerial photograph of 2005 taken before the construction of the large weirs, oxbow lakes, mid-channel bars, point bars, and natural wetlands between the artificial levees were identified. Multiple bars divided the flow of stream water to cause the braided pattern in a particular section. After the construction of the Seungchon weir, aerial photographs of 2013 and 2015 revealed that most of the fluvial landforms disappeared due to the dredging of its riverbed and water level control(maintenance at 7.5El.m). Sentinel-2 images were analyzed to identify differences between before and after the opening of weir gate. Change detection was performed with the near infrared and shortwave infrared spectral bands to effectively distinguish water surfaces from land. As a result, water surface area of the main stream of the Yeongsangang River decreased by 40% from 1.144km2 to 0.692km2. A large mid-channel bar that has been deposited upstream of the weir was exposed during low water levels, which shows the obvious influence of weir on the river bed. Newly formed unvegetated point bars that were deposited on the inside of a meander bend were identified from the remotely sensed images. As the maintenance period of the weir gate opening was extended, various habitats were created by creating pools and riffles around the channel bars. Considering the ecological and hydrological functions of the river bed, it is expected that the increase in bar areas through weir gate opening will reduce the artificial interference effect of the weir.

The Study of Radon Activity and Uranium Concentration of Ground Water and Surface Water (지하수와 지표수에서의 라돈 및 우라늄의 실태 조사)

  • Oh, Youngmi;Lee, Jongbok;Shin, Kyungjin;Kim, Hakchul;Lee, Jaehee;Hwang, Sangchul;Jung, Sanggi;Lee, Sangtae
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.201-205
    • /
    • 2007
  • This paper reports the amount of $^{222}Rn$ and $^{238}U$ in 18 sites of ground water and 30 sites of surface water. The instrument used to count $^{222}Rn$ activity was the liquid scintillation counter (LSC) which could resolute ${\alpha}$ and ${\beta}$ radiations. And $^{238}U$ was analyzed by the inductively coupled plasma (ICP). Radon and Uranium were not detected in raw and treated water which were sampled in a water treatment plant. However, radon ($^{222}Rn$) was high concentration in ground water from Jeon-la, Gang-won. So was uranium ($^{238}U$) in case of ground water from Gang-won, Choong-chung. Radon ($^{222}Rn$) activities were detected less than 15 pCi/L at 5 sampling points, 15~300 pCi/L at 7 sampling points, 300~4000 pCi/L at 6 sampling points. However, Radon ($^{222}Rn$) activities of all ground water samples were less than 4,000 pCi/L, which was bellow American Alternative Maximum Contamination Level (AMCL). Uranium ($^{238}U$) concentrations were less than $0.1{\mu}g/L$ at 5 sampling points, from $0.1{\mu}g/L$ to $20{\mu}g/L$ at 13 sampling points. Uranium was not detected in about 30% of the whole samples, but the concentration ranged from relatively low to high concentrations depending on the sampling point. The minimum detectable activity (MDA) of radon was 15 pCi/L. and the detection limit of uranium was $0.1{\mu}g/L$.

Development of relationship equation for vehicle sensor signal and observed rainfall (차량용 강우센서의 Signal과 관측강우의 관계식 개발)

  • Lee, Suk Ho;Kim, Young Gon;Kim, Byung Sik
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • A vehicle rainfall sensor is made to control the operating speed of wipers depending on rainfall. Therefore this is the apparatus to determine the velocity phase of the wipers roughly based on the amount of rainfall. However, the technology which can judge the size of rainfall amount besides determining speed level of the wipers is developing according to the development of the function of rainfall sensor due to the development of technology. In this study, a rainfall measurement by using light scattering by precipitation particles was used. This measurement is to use light signal reflection from front glass and the bigger particle is the less detection of light by light scattering. The detection area of the rainfall sensor and detection channel were extended sizes to increase the accuracy of the rainfall. Also the W-S-R relational expression was developed by using a relationship between the specific precipitation (R) and the amount of sensor detection (S) when there is speed change of the wipers (W) and an indoor rainfall apparatus was used to convert sensing signal to rainfall. The signal system of vehicle rainfall sensor can be converted to the actual rainfall amount by using this formula and if this is provided to users then the vehicle observation network can produce higher-resolution than actual observation network can be produced.

Evaluation of Pre-treatment Stages for Microcystins Analysis using LC/MS/MS (LC/MS/MS 분석을 위한 microcystins 전처리 단계별 효율성 연구)

  • Kim, Hwa-Bin;Park, Hae-Kyung;Moon, Jeong-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.720-726
    • /
    • 2009
  • We investigated the most effective pre-treatment processes and LC/MS/MS condition for microcystins analysis. With a step-by-step pre-treatment, efficiencies of several established methods were compared. At the level of cell burst, sonication method was found to be the most efficient. As a mycrocystins first extraction solvent, 5% acetic acid showed the highest efficiency. An isolation and recovery rate of mycrocystins of ODS Sep-Pak $C_{18}$ cartridge was higher than HLB SPE cartridge. As a final elution solvent from cartridge, 100% MeOH had a better efficiency than others. Using a LC/MS/MS, effective analytical methods were established. C18 reverse column was used and gradient elution was performed with using acetonitrile, 0.1% formic acid as a mobile phase. We analysed to 0.8 mL/min flow rate fit to the $5{\mu}m$ particle size column and $55^{\circ}C$ housing temperature. The validity of established analytical method was evaluated that MDL as average $0.050{\pm}0.014{\mu}g/L$ and LOQ as average $0.160{\pm}0.045{\mu}g/L$ had a good sensitivity over 40 magnification rather than $2{\mu}g/L$ detection limit of HPLC.

Water-soluble Vitamin Content in Dishes Containing Meat and Seafood (육류 및 수산물을 이용한 조리식품에 함유된 수용성 비타민 함량)

  • Jin, Minguen;Kim, Byung Hee;Kim, Min-Hee;Yoon, Sung Won;Kim, Younghwa
    • Journal of the Korean Society of Food Culture
    • /
    • v.36 no.5
    • /
    • pp.502-511
    • /
    • 2021
  • In this study, the content of water-soluble vitamins such as vitamin B1 (thiamin), B2 (riboflavin), B3 (niacin), B5 (pantothenic acid), B6 (pyridoxine), B7 (biotin), B12 (cyanocobalamin), and C (ascorbic acid) in dishes containing meat and seafood consumed in Korea were determined by high-performance liquid chromatography (HPLC) with ultraviolet and fluorescence detection. All analyses were performed under strict quality control of vitamins B1, B2, B3, B5, B6, B7, B12, and C. The highest content of vitamin B1 was observed in Bugeo-gangjeong (1.373 mg/100 g) and the highest level of vitamin B2 (5.162 mg/100 g) was found in pig liver. Bugeo-gangjeong showed the highest content of vitamin B3 (21.676 mg/100 g), and kkomak-muchim contained considerable amounts (43.310 mg/100 g) of vitamin B5. Vitamin B6 was not detected in most seafood dishes except for yangnyeom myeongran-jeot (0.274 mg/100 g) and was present at low levels or not present at all in meat dishes. The highest content of vitamin B7 was 6.506 ㎍/100 g in saeu-jeon and kkomak-muchim showed the highest content (21.132 ㎍/100 g) of vitamin B12. The highest content of vitamin C was in yangnyeom myeongran-jeot (84.508 mg/100 g). In addition, the analysis methods of each water-soluble vitamin were verified. These results showed that seafood-based ingredients in several dishes could be a good source of water-soluble vitamins.

Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System (지역난방 냉각수 배관의 용접부 파손 분석)

  • Jeong, Joon-Cheol;Kim, Woo-Cheol;Kim, Kyung Min;Sohn, Hong-Kyun;Kim, Jung-Gu;Lee, Soo-Yeol;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.296-301
    • /
    • 2020
  • Failure analysis on the welded type 304 pipe used for cooling water piping in the district heating primary side was conducted. Inorganic elements and bacteria in the cooling water and in corrosion products were analyzed, and the weldment was inspected by microscopy and a sensitization test. Corrosion damages were observed in the heat-affected zone, on weld defects such as incomplete fusion or excessive penetration caused by improper welding, or/and at the 6 o'clock position along the pipe axial direction. However, the level of concentration of chloride in the cooling water as low as 80 ppm has been reported to be not enough for even a sensitized type 304 steel, meaning that the additional corrosive factor was required for these corrosion damages. The factor leading to these corrosion damages was drawn to be the metabolisms of the types of bacteria, which is proved by the detection of proton, sulfur containing species, biofilms, and both bacteria and corrosion product analyses.

Effects of Heavy Metal and Salinity on Electrical Conductivity in Fully Saturated Sand (포화된 사질토의 전기전도도에 중금속과 염분 농도가 미치는 영향)

  • Lee, Dongsoo;Hong, Young-Ho;Hong, Won-Teak;Chae, Kwang-Seok;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.10
    • /
    • pp.23-34
    • /
    • 2017
  • As the electrical property of fully saturated soils is dependent on the pore water, it has been commonly used for the detection of the contamination into the ground. The objective of this study is to investigate the electrical characteristics according to the salinity and the lead concentration in fully saturated soils. Fresh water and saline water with the salinity of 1%, 2% and 3%, which are mixed with 6 different lead solutions with the range of 0~10 mg/L, are prepared in the cylindrical cell incorporated with sensors for measuring electrical resistance and time domain reflectometry signal. Then, the dried sands are water-pluviated into the cell. The electrical resistance and the time domain reflectometry signal are used to estimate the electrical conductivity. Test results show that electrical conductivity determined from electrical resistance at the frequency of 1 kHz continuously increases with an increase in the lead concentration, thus it may be used for the estimation of the contaminant level. In addition, the electrical conductivity estimated by the time domain reflectometry changes even at very low concentration of lead, the variation rate decreases as the lead concentration increases. Thus, the time domain reflectometry can be used for the investigation of the heavy metal leakage. This study demonstrates that complementary characteristics of electrical resistance and time domain reflectometry may be used for the detection of the leakage and contamination of heavy metal in coastal and marine environments.

Comparison of ANN model's prediction performance according to the level of data uncertainty in water distribution network (상수도관망 내 데이터 불확실성에 따른 절점 압력 예측 ANN 모델 수행 성능 비교)

  • Jang, Hyewoon;Jung, Donghwi;Jun, Sanghoon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1295-1303
    • /
    • 2022
  • As the role of water distribution networks (WDNs) becomes more important, identifying abnormal events (e.g., pipe burst) rapidly and accurately is required. Since existing approaches such as field equipment-based detection methods have several limitations, model-based methods (e.g., machine learning based detection model) that identify abnormal events using hydraulic simulation models have been developed. However, no previous work has examined the impact of data uncertainties on the results. Thus, this study compares the effects of measurement error-induced pressure data uncertainty in WDNs. An artificial neural network (ANN) is used to predict nodal pressures and measurement errors are generated by using cumulative density function inverse sampling method that follows Gaussian distribution. Total of nine conditions (3 input datasets × 3 output datasets) are considered in the ANN model to investigate the impact of measurement error size on the prediction results. The results have shown that higher data uncertainty decreased ANN model's prediction accuracy. Also, the measurement error of output data had more impact on the model performance than input data that for a same measurement error size on the input and output data, the prediction accuracy was 72.25% and 38.61%, respectively. Thus, to increase ANN models prediction performance, reducing the magnitude of measurement errors of the output pressure node is considered to be more important than input node.