• 제목/요약/키워드: Water injection

검색결과 1,680건 처리시간 0.029초

혈압강하제 국산 자원생약의 개발에 관한 연구(III) -한국산 두중(杜仲)의 가토(家兎) 혈압(血壓)에 미치는 영향- (Studies on the Development of Antihypertensive Agents from Korean Crude Drugs(III) -Influence of Eucommial Cortex of Korea on the Blood Pressure Responses of Rabbits-)

  • 정명현;박정완
    • 생약학회지
    • /
    • 제6권1호
    • /
    • pp.39-42
    • /
    • 1975
  • Influence of Eucommiae Cortex in Korea on the blood pressure of the rabbit was examined, 1) The intravenous injection of 3 mg/kg, 10 mg/kg and 30 mg/kg of the water extract to the rabbit decreased its blood pressure to $9.7\;{\pm}\;1.9,\;26.4\;{\pm}\;1.7\;and \;35.5\;{\pm}\;2.7\;mmHg$. respectively. 2) The intravenous injection of 10 mg/kg of the water extract did not show any remarkable influence to the blood pressure caused by the intravenous injection of acetylcholine $10^{-8}\;g/kg\; and \;10^{-7}\;g/kg$. 3) The intravenous injection of the water extract after the intravenous injection atropine 2mg/kg did not show any remarkable change to the blood pressure 4) The intravenous injection of the water extract after the intravenous injection of propranolol 2mg/kg slightly decreased the blood pressure.

  • PDF

산화-막여과에 의한 망간 제거 시 과망간산과 차아염소산 복합 주입의 효과 (Multiple injection of permanganate and hypochlorite for manganese removal by oxidation combined with membrane filtration)

  • 곽효은;박정원;민소진;임주완;김기홍;이호성;남창현;박용민;박병규
    • 상하수도학회지
    • /
    • 제32권3호
    • /
    • pp.211-220
    • /
    • 2018
  • The water containing soluble manganese may cause problems such as discolored water, unpleasant taste, fouling or scaling of pipes in water distribution system, and so on. Conventional water treatment processes using sand filtration or sedimentation after oxidation, however, cannot often meet manganese standard for drinking water. Two types of oxidants, potassium permanganate ($KMnO_4$) and sodium hypochlorite (NaOCl), were utilized at the same time for manganese oxidation, and then the precipitated manganese oxides were removed by low pressure membrane filtration in this study. In batch experiments, the multiple injection of both oxidants showed more effective manganese removal than did the single injection using either of them. Moreover, the deterioration of manganese removal at low temperature was less serious for the multiple injection than that for the single injection. Manganese removal by the continuous system of oxidation by multiple injection combined with membrane filtration was higher than those by batch experiments at the same oxidation conditions. In addition, less membrane fouling was observed for membrane filtration with oxidation during continuous membrane filtration than membrane filtration without oxidation. These results indicate that the oxidation by multiple injection coupled with membrane filtration was efficient and applicable to actual water treatment for manganese removal.

물분사 폐열회수 보일러의 효용성에 대한 실험적 검증 (Experimental Validation on Performance of Waste-heat-recovery Boiler with Water Injection)

  • 신재훈;박태준;조현석;유준상;문석수;이창언
    • 한국분무공학회지
    • /
    • 제28권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The waste-heat-recovery boiler with water spray (HR-B/WS) applies the heat exchange between the inlet air and exhaust gas with the water spray into the inlet air. The evaporation of water in the inlet air promotes heat recovery from the exhaust gas so that thermal efficiency can be improved by the enhanced condensing effect. The NOx emission can also be reduced by lowering the flame temperature due to the dilution effect of the water. In this study, the validity of this concept is examined by the practical boiler test performed with a 24 kW condensing boiler under the full load condition according to the water injection amount. The theoretical amount of water injection is calculated under the assumption of full evaporation of the sprayed water, which is calculated as 50 g/min. Since the injected water cannot evaporate fully in the actual system, the maximum water spray amount is set as 100 g/min. The results showed that the water injection can increase the thermal efficiency up to 95.59% and reduce NOx and CO emissions simultaneously to 8.9 ppm and 35 ppm at 0% of O2. Although the heat energy loss increased due to the unevaporated water, the increase in water injection amount caused higher thermal efficiency due to the increased amount of the evaporated water.

상수도수 불소투입에 관한 연구 (A Study of Fluoride Injection in Water Supply)

  • 김성순;이양규;김갑진;서성원
    • 상하수도학회지
    • /
    • 제10권4호
    • /
    • pp.73-84
    • /
    • 1996
  • Fluoride was first introduced into the drinking water of residents of Grand Rapids, Michigan in 1945 for the prevention of dental caries. Ever since, growing numbers of communities favor fluoridation. Now, over 7000 communities in the United States are adding F(0.7~1.2ppm) to their drinking water. The most effective to prevent tooth decay is putting lower concentrated fluoride(F, 0.7~1.2ppm) into drinking water. However, exact fluoride injection amount have not been decided, because the research of the fluoride injection effect was insufficient. Therefore, after separating fluoridation and non-fluoridation into public water supplies, we investigated concentration of fluoride, alkalinity, Al, Ca, Mg, evaporation residuals in APT, domestic, commercial area. Then, we decided allowable concentration of fluoride, injection point of fluoride in water supply system, cost effectiveness.

  • PDF

물분사 수소 가스터빈의 출력 향상을 위한 연구 (A Study for the Output Increament of the Hydrogen Gas Turbine with Water Injection)

  • 정귀성;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 1998
  • Most of today's energy supply is obtained from fossil fuels. Despite of high energy density, higher store efficiency and long mileage, fossil fuels cause environmental pollution and their reserves are limited. In this study pure hydrogen gas and oxygen gas are burned without the emission of pollution. A gas turbine is used to obtain power. Water is injected into a combustor, which prevents overheating and recovers cooling heat. Excessively supplied water is recirculated. With variation of mass flow rate and equivalence ratio, the affection of water injection rate and the temperature of injected water on efficiency and power are experimented. Injected water gets cooling heat, is expanded from liquid to vapor and raises the thermal efficiency. It is enable to determine the rate of water injection, which makes the maximum power. The increase of temperature of water injection raises the efficiency of the system.

  • PDF

칼로리/수분 (C/W)비를 고려한 고온호기 처리법에서의 처리량 증가 (Increase of treatment amount of thermophilic oxic process considering calorie/water (C/W) ratio)

  • 전경호;최동윤;송준익;박규현;곽정훈;김재환;강희설
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.203-210
    • /
    • 2010
  • The signification of calorie/water (C/W) ratio was investigated in the treatment of highly concentrated organic wastes by thermophilic oxic process (TOP). Swine waste was used in this study. When C/W ratio was 1.6, most of swine waste was decomposed and all water was evaporated in the 24-h injection cycle. To improve treatment efficiency of TOP treating swine waste, the effect of shortening the swine waste injection cycle was examined. The shortening of injection cycle was conducted to stimulate the activity of thermophilic bacteria. A high temperature in the reactor was maintained by shortening of the injection cycle. When the swine waste injection cycle was shortened, the C/W ratio was fixed at 1.6. As a result, by shortening the swine waste injection cycle from 24-h to 12 and 6-h, the maximum loading rate of swine waste per day could be improved 1.9 and 3.5 times, respectively.

하나로 비상 보충수 공급계통의 노심 주입 냉각유량 해석 (THE ANALYTIC ANALYSIS OF THE CORE INJECTION COOLING FLOW RATE FOR EMERGENCY WATER SUPPLY SYSTEM IN HANARO)

  • 박용철;김봉수;김경연;우종섭
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.39-44
    • /
    • 2005
  • In HANARO, a multi-purpose research reactor of 30 MWth, the emergency water supply system consists essentially of an emergency water storage tank located in the level of about thirteen meter (13 m) above the reactor core, a three inch ('3\%') diameter water injection pipe line including injection valves from the tank to the reactor cooling inlet pipe and a test loop to do periodic system performance test. When the water level of the reactor pool comes down to the extremely low due to a loss of reactor pool water accident the emergency water stored in the tank should be fed to the core by the gravity force and at that time the design flow rate is eleven point four kilogram per second (11.4 kg/s). But it is impossible periodically to measure the injection flow rate under the emergency condition because the normal water level should be maintained during the reactor operation. This paper describes a flow network analysis to simulate the flow rate under the emergency condition. As results, it was confirmed through the analysis results that the calculated flow rate agrees with the design requirement under the emergency condition.

  • PDF

미분무수 분사 특성에 따른 가열 챔버 내 냉각 성능 수치 해석 (Numerical Analysis of Effects of Water Mist Injection Characteristics on Cooling Performance in Heated Chamber)

  • 수먼;이상욱
    • 한국분무공학회지
    • /
    • 제17권2호
    • /
    • pp.64-70
    • /
    • 2012
  • Water mist fire suppression systems which use relatively small droplets of water with high injection pressure are increasingly being used in wider applications because of its greater efficiency, low flooding damage and low toxicity. However, the performance of the system significantly relies on the water mist characteristics and it requires better understanding of fire suppression mechanism of water mist. In the present study, computational fluid dynamics simulations were carried out to investigate cooling performance of water mist in heated chamber. The gas phase was prepared with natural convection heat transfer model for incompressible ideal case and then the effects of water mist injection characteristics on cooling capabilities were investigated upon the basis of the pre-determined temperature field. For the simulation of water mist behavior, Lagrangian discrete phase model was employed by using a commercial code, FLUENT. Smaller droplet sizes, greater injection angles and higher flow rates provided relatively higher cooling performance.

해수침투 저감을 위한 균열암반 대수층 내 담수주입시험 (Fresh Water Injection Test in a Fractured Bedrock Aquifer for the Mitigation of Seawater Intrusion)

  • 신제현;변중무
    • 자원환경지질
    • /
    • 제43권4호
    • /
    • pp.371-379
    • /
    • 2010
  • 연안지역 염수와 담수가 혼재하는 전이대에서 해수침투 피해개선을 목적으로 균열암반을 통한 담수주입시험을 수행하고 그 효과를 모니터링하였다. 담수주입은 절대적으로 그 지역의 지질학적, 수리학적 특성에 따라 좌우되며, 특히 파쇄대나 투수성 미고결 지층 등의 특성 파악이 중요하다. 연구 지역의 염담수 분포특성을 고려하여 두 개의 주요 연안 대수층인 충적층과 균열암반 구간을 통한 담수주입이 가능하도록 시추공을 설계 및 굴착하였으며, 균열암반 대수층 내 담수주입을 위하여 현장에서의 시험 준비, 이동, 조립 및 장비의 유지보수가 간단하도록 착탈식인 모듈화되어 있는 주입시스템을 제작하여 적용하였다. 시추공영상화검층을 통해 전체적인 균열의 특성을 파악하였고, 이를 바탕으로 주입공 및 관측공 간 투수성 파쇄대의 확인을 위한 구간별 담수주입 및 모니터링을 실시하여 담수주입 구간을 선정하였다. 담수주입시험 결과, 관측공의 일정 심도에서 담수가 유입되어 시간이 경과함에 따라 상부 구간의 전기전도도도 점진적으로 감소함을 보였으며, 담수주입 중단 및 패커를 해지한 후에도 유입된 심도에서 점진적으로 전기전도도값이 증가하기는 하지만 그 증가폭이 전체적으로 낮아 담수주입의 효과가 있음을 확인하였다. 또한 장기적으로 전기전도도값을 모니터링함으로써 담수주입의 효과가 수개월 후에도 지속됨을 확인하였으며, 이는 담수주입에 의해 일정 정도의 해수침투 피해에 대한 개선효과를 기대할 수 있음을 시사한다.

실내모형시험을 통한 지반혼합 및 주입공법의 노후저수지 차수 보강성능 비교 연구 (A Comparative Study on the Impermeability-reinforcement Performance of Old Reservoir from Injection and Deep Mixing Method through Laboratory Model Test)

  • 송상훤
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.45-52
    • /
    • 2022
  • Of the 17,106 domestic reservoirs(as of December 2020), 14,611 are older than 50 years, and these old reservoirs will gradually increase over time. The injection grouting method is most applied to the reinforcement method of the aging reservoir. However, the injection grouting method is not accurate in uniformity and reinforced area. An laboratory model test was conducted to evaluate the applicability of the deep mixing method, which compensated for these shortcomings, as a reservoir reinforcement method. As a result of calculating the hydraulic conductiveity for each method through the model test results, the injection grouting method was calculated as a hydraulic conductiveity value that was about 7.5 times larger than that of the deep mixing method. As a result of measuring the water level change in the laboratory model test, it was found that the water level change decreased in the injection method and deep mixing method compared to the non-reinforcement method. In addition, deep mixing method showed a water level change of about 15% based on 40 hours compared to the injection method, indicating that the water-reducing effect was superior to that of the injection method.