• Title/Summary/Keyword: Water exchange ratio

Search Result 187, Processing Time 0.022 seconds

The Removal of Heavy Metals in Aqueous Solution by Hydroxyapatite (Apatite를 이용한 중금속 제거)

  • 강전택;정기호
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.325-330
    • /
    • 2000
  • The hydroxyapatite (HAp) for the present study was prepared by precipitation method in semiconductor fabrication and the crystallized at ambient to 95$0^{\circ}C$ for 30min in electric furnace. The ion-exchange characteristics of HAp for various heavy metal ions such as $Cd^{2+}, Cu^{2+}, Mn^{2+}, Zn^{2+}, Fe^{2+}, Pb^{2+}, Al^{3+}, and Cr^{6+}$ in aqueous solution has been investigated. The removal ratio of various metal ions for HAp were investigated with regard to reaction time, concentration of standard solution, amount of HAp and pH of solution. The order of the ions exchanged amount was as follws: $Pb^{2+}, Fe^{3+}>Cu^{2+}>Zn^{2+}>Al^{3+}>Cd^{2+}>Mn^{2+}>Cr^{6+}. The Pb^{2+}$ ion was readily removed by the Hap, even in the strongly acidic region. The maximum amount of the ion-exchange equilibrium for $Pb^{2+}$ ion was about 45 mg/gram of HAp. The HAp would seem to be possible agent for the removal of heavy metal ions in waste water by recycling of waste sludge in semiconductor fabrication.

  • PDF

Studies on the Cation Exchangers from Coals (炭質陽이온交煥體 製造에 關한 硏究)

  • Lee, Bum-Soon;Yoo, In-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.62-66
    • /
    • 1957
  • With the intention of preparing cation exchangers from the domestic coals, and using these for softening hard water and some other purposes, seven kinds of raw coal were tested and the results are as follows. 1) The following conditions of preparation were given the good results. Reaction time 5 hours Reaction temperature $95^{\circ}$ Concentration of sulfuric acid 98% Amount of sulfuric acid 10 times to the sample (as weight) 2) The raw coals which is rich in fixed carbon and have the fuel ratio 0.8 to 1.0 were suitable, and Kampo lignite has shown the best results. 3) The cation exchangers from coals were able to exchange the cation, both hydrogen and sodium type dynamically and statically, like the synthetic ion exchange resin. The exchange capacities were as follows. Total capacity 1.60 meq/g. Breakthrough capacity 1.30 meq/g. Usable breakthrough capacity 1.20 meq/g National Central Research laboratory

  • PDF

Manufacture of Sterilizing Media with Shell Powder and It's Application to the Filter of Water Clarifier (패각분말을 이용한 살균성 메디아의 제조 및 정수기용 필터에 대한 응용)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1027-1034
    • /
    • 2006
  • Antimicrobial powder was made by exchanging silver ion on calcined oyster shell. On the purpose of application to water clarifier, bail-type media mixed with antimicrobial powder and $0{\sim}30%$ white kaoline were made. The sterilization effect, pore size distribution and zeta potential was tested to indicate the condition for the media of water clarifier. From these tests, it was confirmed that this media have an excellent sterilization power on $G^-\;and\;G^+$ germs. As the concentration of the exchanged silver ion increased, the surface charge density of the anions on the surface of the media also increased. The surface pore size decreased with the concentration of silver ion and 20% more white kaoline ratio. Consequently, mixing ratio of white kaoline would appear to indicate the optimun condition as media have sterilization power.

높은 유상비에서 Rhodococcus rhodochrous IGTS8를 이용한 탈황효율의 분석과 5-L 배양기에의 적용

  • Kim, Jin-Hong;Park, Hong-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.121-125
    • /
    • 2002
  • Rhodococcus rhodochrous IGTSS (ATCC 5396S) can break organo sulfur compounds such as dibenzothiophene. Since the environment for biodesulfurization process is invariably hydrophobic, parameters in hydrophobic systems should be examined. For the model oil, hexadecane-containing 5.43mM dibenzothiophene, the volumetric desulfurization rate was decreased with the oil-to-aqueous phase ratio up to 50%. The rate declined sharply after 48h because the cell activity, which is refreshed by medium exchange, was lost. To supply the exhausted nutrients, medium exchange was performed. At 30% oil phase, most of DBT was removed by medium exchange on 48h, and the rate was 2.03mg $DBT_{removed}/L_{dispersion}-hr.$ At 50% oil phase, medium exchange on 60h was performed and the rate was 1.79mg $DBT_{removed}/L_{dispersion}-hr.$ The 300mL flask system was scaled up to a 5-L bioreactor system. On 60 h, a medium exchange was performed and the rate was 5.28mg $DBT_{removed}/L_{dispersion}-hr.$ and all of DBT was removed. It means that we can use the biodesulfurization process even 10 the high oil-to-water phase by some appropriate methods such as controlled feeding of key nutrients and the dilution or removal of some toxic metabolites by continuous reactor.

  • PDF

Applicable Feasibility of Fenton Oxidation and Zeolite Ion Exchange Processes for Removal of Non-Biodegradable Matters and Ammonia in Livestock Wastewater (축산폐수 중의 난분해성 물질 및 암모니아 제거를 위한 Fenton 산화와 Zeolite 이온교환 공정의 적용 가능성)

  • Cho, Chang-Woo;Kim, Byoung-Young;Chae, Soo-Choen;Chung, Paul-Gene
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.600-606
    • /
    • 2007
  • Livestock wastewater containing concentrated organic matters and nutrients has been known as one of the major pollutants. It is difficult to apply the conventional activated sludge process to treat livestock wastewater because of high Non-biodegradable (NBD) matter and ammonia. The objectives of this study are to remove NBD matters including aromatic compounds and ammonia in livestock wastewater using Coagulation-Fenton oxidation-Zeolite (CFZ) processes and ascertain applicable feasibility in the field through pilot plant experiment. NBD matters and color remained in the treated water were removed over 92% by Fenton oxidation as the second treatment process. Ammonia was removed by over 99.5% in the zeolite ion exchange process as the last treatment method. From $UV_{254}$, $E_2/E_3$ ratio and GC/MS analyses of treated water at each process, the aromatic compound was converted to aliphatic and aromaticity was decreased. In pilot scale test, organics and ammonia removal efficiencies were not much different from the result of lab-scale test at various operation conditions. Furthermore, reaction time and dosage of Fenton reagent in pilot scale experiment reduced by 40 min and 50% rather than in lab-scale test. $BOD_5$, $COD_{Mn}$, SS, T-N and T-P of treated water in the pilot-scale experiment also met the effluent standards.

Study on the Ethanol Recovery Process using Dircet Contact Heat Exchange (고온의 기포접촉에 의한 에탄올 회수공정에 관한 연구)

  • Lee, Won-Young;Yeo, Sang-Do;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.176-180
    • /
    • 1995
  • Direct contact heat exchange (DCHE) method has been employed to investigate the separation of ethanol from dilute aqueous solutions. Bubbles at high temperature were dispersed into a continuous liquid phase, generating temperature gradient in air-liquid interface, which causes heat and mass transfer accordingly. The experiments were performed in the ranges of jet regime air flow. The air-water stripping coefficient increased $5{\sim}10,\;and\;1{\sim}1.5$ times as temperature and air flow rate increased, respectively. The recovery ratio based on the initial ethanol concentration reached into 80% at the air flow rate of 84.88 m/min. The initial ethanol concentration showed little effect on the stripping coefficient and the recovery ratio.

  • PDF

Effect of Current Density and Electroosmotic Phenomena on the Desalination Performance of the Electrodialysis Process (전류밀도와 전기삼투 현상이 전기투석 공정의 탈염성능에 미치는 영향)

  • Eun-Seo Cheon;Jae-Hwan Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.272-278
    • /
    • 2023
  • In this study, we analyzed the effects of current density and electroosmotic phenomena on the desalination performance of electrodialysis (ED). We conducted ED experiments under constant voltage conditions, changing the concentration of the concentrate solution from 10 to 200 g/L. During the ED operation, we measured the current density and charge supplied to the stack, the concentration of the diluted and concentrated solutions, and the amount of water transported by electroosmosis to analyze desalination performance. As the concentration of the concentrated solution increased, the selectivity of the ion exchange membrane decreased, resulting in a decrease in current efficiency. Moreover, the current efficiency was found to be influenced by the current density supplied. When the current density exceeded 15 mA/cm2, back diffusion of ions was suppressed, leading to an increase in current efficiency. We also investigated the specific water transport by electroosmosis during the ED operation. We found that the amount of water transported increased proportionally to the concentration ratio of the concentrated and diluted solutions. When the concentration ratio exceeded 100, the specific water transport rapidly increased due to osmotic pressure, making it challenging to obtain a concentrated solution greater than 200 g/L.

Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water (이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향)

  • 황택성;이진혁
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.551-558
    • /
    • 2002
  • It was observed that adsorption characteristics of sulfonated fabric ion-exchanger for separating nickel ion from electroplating rinse water. Swelling ratio was increased by increasing degree of sulfonation and polarity of solvent. Ion-exchange capacity was also increased by increasing degree of sulfonation and showed 3.38 meq/g at 16% sulfonated ion-exchanger. There was little effects of pH. Adsorption equilibrium was attained within 10 min, and adsorption rate was 7.5 mg/min. Adsorption capacity was not changed after 7 cycles of regeneration process. Regeneration adsorption capacity was slightly decreased to 2.01 meq/g. It confirmed that durability of sulfonated fabric ion-exchanger was suitable for adsorption process. Adsorption equilibrium time was linearly increased by increasing L/D and adsorption capacity showed the ion exchange capacity within the range of 2.71 ∼ 3.01 meq/g in continuous process. Design of adsorption column could be possible for L/D<2. Under constant L/D condition, there is no little pH effect when rinse water is acidic solution, and operation condition of adsorption process was optimized under pH 5.

Performance Ratings According to Characteristics of Thermosyphon Solar Hot Water System (자연대류형 태양열온수기의 특성별 성능평가에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Yoo, C.G.;Yoon, H.G.;Kang, M.C.;Lee, D.G.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.9-17
    • /
    • 2000
  • To obtain thermal performance data, an experiment was performed with the two selected thermosyphon systems. The system parameters obtained by experimental data were used to perform TRNSYS simulation and verified TRNSYS model of thermosyphon solar hot water system. The thermosyphon solar hot water system was TYPE 145 which is modified from non-linear model. This model can describe heat exchange type and non-linear efficiency equation. It is possible to analyze the annual energy rate with efficiency equation and system specification. In this paper, we could compare the annual performance of the coil heat exchanger with that of the tank-in-tank heat exchanger. Under the same efficiency and parameter, heat exchange, drain, initial tank temperature, ratio of tank volume over collector area(V/Ac), regional annual performance rating were performed.

  • PDF

Poly(vinylbenzyl chloride-glycidyl methacrylate)/Polyethylene Composite Anion Exchange Membranes for Vanadium Redox Battery Application

  • Park, Min-A;Shim, Joonmok;Park, Se-Kook;Jeon, Jae-Deok;Jin, Chang-Soo;Lee, Ki Bong;Shin, Kyoung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1651-1655
    • /
    • 2013
  • Anion exchange membranes for a vanadium redox flow battery (VRB) were prepared by pore-filling on a PE substrate with the copolymerization of vinylbenzyl chloride (VBC) and glycidyl methacrylate (GMA). The ion exchange capacity, water uptake and weight gain ratio were increased with a similar tendency up to 65% of GMA content, indicating that the monomer improved the pore-filling degree and membrane properties. The vanadium ion permeability and open-circuit voltage were also investigated. The permeability of the VG65 membrane was only $1.23{\times}10^{-7}\;cm^2\;min^{-1}$ compared to $17.9{\times}10^{-7}\;cm^2\;min^{-1}$ for Nafion 117 and $1.8{\times}10^{-7}\;cm^2\;min^{-1}$ for AMV. Consequently, a VRB single cell using the prepared membrane showed higher energy efficiency (over 80%) of up to 100 cycles compared to the commercial membranes, Nafion 117 (ca. 58%) and AMV (ca. 70%).