• 제목/요약/키워드: Water exchange ratio

검색결과 187건 처리시간 0.026초

Apatite를 이용한 중금속 제거 (The Removal of Heavy Metals in Aqueous Solution by Hydroxyapatite)

  • 강전택;정기호
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.325-330
    • /
    • 2000
  • The hydroxyapatite (HAp) for the present study was prepared by precipitation method in semiconductor fabrication and the crystallized at ambient to 95$0^{\circ}C$ for 30min in electric furnace. The ion-exchange characteristics of HAp for various heavy metal ions such as $Cd^{2+}, Cu^{2+}, Mn^{2+}, Zn^{2+}, Fe^{2+}, Pb^{2+}, Al^{3+}, and Cr^{6+}$ in aqueous solution has been investigated. The removal ratio of various metal ions for HAp were investigated with regard to reaction time, concentration of standard solution, amount of HAp and pH of solution. The order of the ions exchanged amount was as follws: $Pb^{2+}, Fe^{3+}>Cu^{2+}>Zn^{2+}>Al^{3+}>Cd^{2+}>Mn^{2+}>Cr^{6+}. The Pb^{2+}$ ion was readily removed by the Hap, even in the strongly acidic region. The maximum amount of the ion-exchange equilibrium for $Pb^{2+}$ ion was about 45 mg/gram of HAp. The HAp would seem to be possible agent for the removal of heavy metal ions in waste water by recycling of waste sludge in semiconductor fabrication.

  • PDF

炭質陽이온交煥體 製造에 關한 硏究 (Studies on the Cation Exchangers from Coals)

  • 이범순;유인상
    • 대한화학회지
    • /
    • 제4권1호
    • /
    • pp.62-66
    • /
    • 1957
  • With the intention of preparing cation exchangers from the domestic coals, and using these for softening hard water and some other purposes, seven kinds of raw coal were tested and the results are as follows. 1) The following conditions of preparation were given the good results. Reaction time 5 hours Reaction temperature $95^{\circ}$ Concentration of sulfuric acid 98% Amount of sulfuric acid 10 times to the sample (as weight) 2) The raw coals which is rich in fixed carbon and have the fuel ratio 0.8 to 1.0 were suitable, and Kampo lignite has shown the best results. 3) The cation exchangers from coals were able to exchange the cation, both hydrogen and sodium type dynamically and statically, like the synthetic ion exchange resin. The exchange capacities were as follows. Total capacity 1.60 meq/g. Breakthrough capacity 1.30 meq/g. Usable breakthrough capacity 1.20 meq/g National Central Research laboratory

  • PDF

패각분말을 이용한 살균성 메디아의 제조 및 정수기용 필터에 대한 응용 (Manufacture of Sterilizing Media with Shell Powder and It's Application to the Filter of Water Clarifier)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제15권11호
    • /
    • pp.1027-1034
    • /
    • 2006
  • Antimicrobial powder was made by exchanging silver ion on calcined oyster shell. On the purpose of application to water clarifier, bail-type media mixed with antimicrobial powder and $0{\sim}30%$ white kaoline were made. The sterilization effect, pore size distribution and zeta potential was tested to indicate the condition for the media of water clarifier. From these tests, it was confirmed that this media have an excellent sterilization power on $G^-\;and\;G^+$ germs. As the concentration of the exchanged silver ion increased, the surface charge density of the anions on the surface of the media also increased. The surface pore size decreased with the concentration of silver ion and 20% more white kaoline ratio. Consequently, mixing ratio of white kaoline would appear to indicate the optimun condition as media have sterilization power.

높은 유상비에서 Rhodococcus rhodochrous IGTS8를 이용한 탈황효율의 분석과 5-L 배양기에의 적용

  • 김진홍;박홍우
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.121-125
    • /
    • 2002
  • Rhodococcus rhodochrous IGTSS (ATCC 5396S) can break organo sulfur compounds such as dibenzothiophene. Since the environment for biodesulfurization process is invariably hydrophobic, parameters in hydrophobic systems should be examined. For the model oil, hexadecane-containing 5.43mM dibenzothiophene, the volumetric desulfurization rate was decreased with the oil-to-aqueous phase ratio up to 50%. The rate declined sharply after 48h because the cell activity, which is refreshed by medium exchange, was lost. To supply the exhausted nutrients, medium exchange was performed. At 30% oil phase, most of DBT was removed by medium exchange on 48h, and the rate was 2.03mg $DBT_{removed}/L_{dispersion}-hr.$ At 50% oil phase, medium exchange on 60h was performed and the rate was 1.79mg $DBT_{removed}/L_{dispersion}-hr.$ The 300mL flask system was scaled up to a 5-L bioreactor system. On 60 h, a medium exchange was performed and the rate was 5.28mg $DBT_{removed}/L_{dispersion}-hr.$ and all of DBT was removed. It means that we can use the biodesulfurization process even 10 the high oil-to-water phase by some appropriate methods such as controlled feeding of key nutrients and the dilution or removal of some toxic metabolites by continuous reactor.

  • PDF

축산폐수 중의 난분해성 물질 및 암모니아 제거를 위한 Fenton 산화와 Zeolite 이온교환 공정의 적용 가능성 (Applicable Feasibility of Fenton Oxidation and Zeolite Ion Exchange Processes for Removal of Non-Biodegradable Matters and Ammonia in Livestock Wastewater)

  • 조창우;김병용;채수천;정팔진
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.600-606
    • /
    • 2007
  • Livestock wastewater containing concentrated organic matters and nutrients has been known as one of the major pollutants. It is difficult to apply the conventional activated sludge process to treat livestock wastewater because of high Non-biodegradable (NBD) matter and ammonia. The objectives of this study are to remove NBD matters including aromatic compounds and ammonia in livestock wastewater using Coagulation-Fenton oxidation-Zeolite (CFZ) processes and ascertain applicable feasibility in the field through pilot plant experiment. NBD matters and color remained in the treated water were removed over 92% by Fenton oxidation as the second treatment process. Ammonia was removed by over 99.5% in the zeolite ion exchange process as the last treatment method. From $UV_{254}$, $E_2/E_3$ ratio and GC/MS analyses of treated water at each process, the aromatic compound was converted to aliphatic and aromaticity was decreased. In pilot scale test, organics and ammonia removal efficiencies were not much different from the result of lab-scale test at various operation conditions. Furthermore, reaction time and dosage of Fenton reagent in pilot scale experiment reduced by 40 min and 50% rather than in lab-scale test. $BOD_5$, $COD_{Mn}$, SS, T-N and T-P of treated water in the pilot-scale experiment also met the effluent standards.

고온의 기포접촉에 의한 에탄올 회수공정에 관한 연구 (Study on the Ethanol Recovery Process using Dircet Contact Heat Exchange)

  • 이원영;여상도;최용희
    • 한국식품과학회지
    • /
    • 제27권2호
    • /
    • pp.176-180
    • /
    • 1995
  • 고온의 기포를 액상에 분산시켜 형성되는 기-액상간의 온도구배로 인한 열 및 물질전달 방법인 고온기포접촉법을 도입하여 수용액으로부터 에탄올의 분리능력을 검토하고 회수율을 살펴보았다. 기포의 높은 분산속도는 액상내에서 jet regime을 형성하였으며 온도와 유속에 따라 air-water stripping coefficient는 각각 $5{\sim}10,\;1{\sim}1.5$배 증가하였다. 액상과 기포의 온도차가 클수록 stripping coefficient의 값이 높았으며 유속보다는 온도가 분리능력에 더 큰 영향을 미치는 것으로 나타났다. 회수율은 고온일 때와 유속이 클수록 증가해 $150^{\circ}C$, 84.88m/min 일때 80%의 회수율을 나타내었다. 고온기포접촉법은 stripping coefficient가 에탄올의 초기농도에 큰 영향을 받지 않으므로, 알코올 발효공정에서 배양액의 농도가 5% 이상 높아지면 알코올 생성균주의 생장장해를 일으켜 알코올 생산 수율이 떨어지는 생산물 저해작용을 줄이고 알코올을 회수하는 공정으로 응용될 수 있다.

  • PDF

전류밀도와 전기삼투 현상이 전기투석 공정의 탈염성능에 미치는 영향 (Effect of Current Density and Electroosmotic Phenomena on the Desalination Performance of the Electrodialysis Process)

  • 천은서;최재환
    • 공업화학
    • /
    • 제34권3호
    • /
    • pp.272-278
    • /
    • 2023
  • 이 연구에서는 전류밀도와 전기삼투 현상이 전기투석(electrodialysis, ED)의 탈염성능에 미치는 영향을 분석하였다. 농축액의 농도를 10~200 g/L로 변화시키면서 정전압 조건에서 ED 실험을 진행하였다. ED 운전과정에서 스택에 공급되는 전류밀도와 전하량, 희석액과 농축액의 농도, 그리고 전기삼투에 의한 물 이동량을 측정하여 탈염성능을 분석하였다. 농축액의 농도가 증가함에 따라 이온교환막의 선택성이 감소하여 전류효율이 감소하였다. 또한 전류효율은 스택에 공급되는 전류밀도에 영향을 받는 것으로 나타났다. 전류밀도가 15 mA/cm2 이상에서는 역 확산이 억제되어 전류효율이 증가하였다. ED 운전과정에서 전기삼투에 의한 물 이동량을 분석하였다. 물 이동량은 농축액과 희석액의 농도비에 비례하여 증가하는 것을 알 수 있었다. 농도비가 100 이상에서는 삼투압에 의한 물 이동량이 급격히 증가하여 200 g/L 이상의 농축액을 얻는데 한계가 있는 것으로 나타났다.

이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향 (Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water)

  • 황택성;이진혁
    • 폴리머
    • /
    • 제26권5호
    • /
    • pp.551-558
    • /
    • 2002
  • 술폰산형 섬유이온교환체를 이용하여 도금 폐수 중 니켈 이온 분리를 위해 각각의 조건에 따른 니켈 이온에 대한 흡착 특성을 관찰하였다. 술폰산형 섬유이온교환체의 함수율은 술폰화도 극성이 클수록 크게 나타났으며 이온교환용량은 술폰화도가 증가함에 따라 증가하였으며 술폰화도 16%에서 3.38 meq/g로 높게 나타났다. 니켈이온의 흡착은 pH 변화에 따라 크게 변화하지 않았고 모든 흡착은 10분 이내에 약 7.5 mg/min의 흡착속도로 매우 빠르게 평형에 도달하였다. 재생 시 흡착용량은 7회까지 3.15 meq/g으로 거의 100% 가까이 탈착되었으며 그 이상에서는 2.01 meq/g으로 약간 감소하는 것으로 보아 본 연구에 사용한 이온교환체는 내구성에 문제가 없는 것으로 판단되었다. 한편 흡착평형 시간은 L/D의 값이 증가함에 따라 선형적으로 증가하였으며, 최대 흡착용량은 각각 2.71∼3.01 meq/g으로 약간 증가하였고 L/D의 변화에 크게 영향이 없는 것으로 보아 L/D<2로 흡착칼럼의 설계가 가능할 것으로 사료되었다. 또한 이온교환 섬유의 충전비가 일정할 때 pH 변화에 따른 니켈 이온의 흡착량은 산성 pH에서는 큰 변화가 없는 것으로 보아 도금수세액의 pH가 산성인 점을 고려할 때 pH 5 이하가 적합한 것으로 판단되었다.

자연대류형 태양열온수기의 특성별 성능평가에 관한 연구 (Performance Ratings According to Characteristics of Thermosyphon Solar Hot Water System)

  • 강용혁;곽희열;유창균;윤환기;강명철;이동규
    • 태양에너지
    • /
    • 제20권2호
    • /
    • pp.9-17
    • /
    • 2000
  • To obtain thermal performance data, an experiment was performed with the two selected thermosyphon systems. The system parameters obtained by experimental data were used to perform TRNSYS simulation and verified TRNSYS model of thermosyphon solar hot water system. The thermosyphon solar hot water system was TYPE 145 which is modified from non-linear model. This model can describe heat exchange type and non-linear efficiency equation. It is possible to analyze the annual energy rate with efficiency equation and system specification. In this paper, we could compare the annual performance of the coil heat exchanger with that of the tank-in-tank heat exchanger. Under the same efficiency and parameter, heat exchange, drain, initial tank temperature, ratio of tank volume over collector area(V/Ac), regional annual performance rating were performed.

  • PDF

Poly(vinylbenzyl chloride-glycidyl methacrylate)/Polyethylene Composite Anion Exchange Membranes for Vanadium Redox Battery Application

  • Park, Min-A;Shim, Joonmok;Park, Se-Kook;Jeon, Jae-Deok;Jin, Chang-Soo;Lee, Ki Bong;Shin, Kyoung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1651-1655
    • /
    • 2013
  • Anion exchange membranes for a vanadium redox flow battery (VRB) were prepared by pore-filling on a PE substrate with the copolymerization of vinylbenzyl chloride (VBC) and glycidyl methacrylate (GMA). The ion exchange capacity, water uptake and weight gain ratio were increased with a similar tendency up to 65% of GMA content, indicating that the monomer improved the pore-filling degree and membrane properties. The vanadium ion permeability and open-circuit voltage were also investigated. The permeability of the VG65 membrane was only $1.23{\times}10^{-7}\;cm^2\;min^{-1}$ compared to $17.9{\times}10^{-7}\;cm^2\;min^{-1}$ for Nafion 117 and $1.8{\times}10^{-7}\;cm^2\;min^{-1}$ for AMV. Consequently, a VRB single cell using the prepared membrane showed higher energy efficiency (over 80%) of up to 100 cycles compared to the commercial membranes, Nafion 117 (ca. 58%) and AMV (ca. 70%).