• Title/Summary/Keyword: Water exchange rate

Search Result 287, Processing Time 0.024 seconds

A Study on the Changes of Water Quality due to the Development of Harbor and its Improvement (항만개발에 따른 수질변화 및 개선책에 관한 연구)

  • 국승기;이중우;최성용;김강민
    • Journal of Korean Port Research
    • /
    • v.13 no.1
    • /
    • pp.123-132
    • /
    • 1999
  • It is very important to quantitatively assess the movement of sea water and pollutant dispersion before or after constructing shore structures such as breakwater considering marine environment and long-term utilization of those structures. This assesment is possible through the use of simulation models designed to predict water movement and pollutant dispersion in a certain area. In this study the numerical computations were carried out to predict the sea water quality in the Ilgwang Harbor located at the east coast of Pusan. The flow patters were investigated before and after the development of Ilgwang Harbor. The computational models adopting ADI Method (Alternating Direction Implicit Method) were used here and were already verified from the previous studies. As a results of this study the tidal exchange in Ilgwang Harbor after development proved to be worse due to the increased semi-enclosed at the harbor limit. In order to improve the water quality of this area after development a new method was proposed to improve water quality in the semi-enclosed bay by creation and control of tidal residual currents. For this purpose the unsymmetric structures so called bottom roughness were introduced in this study. The simulation was carried out on the basis of the study by Komatsu et. al. and Gug and we made a conclusion that it is possible to generate a new tidal residual current and to increase the tidal exchange by application of bottom roughness arrangement.

  • PDF

Basic Study for Development of Denitrogenation Process by Ion Exchange(IV) -A Kinetic Study in Continuous Column and an Economic Analysis- (이온교환법에 의한 탈질소 공정개발의 기초연구(IV) -연속식 반응기에서의 속도론과 경제성 분석-)

  • Lee, Min-Gyu;Ju, Chang-Sik;Chae, Yong-Gon;Kim, Sung-Il;Lee, Dong-Hwan;Yoon, Tae-Kyung
    • Journal of Environmental Science International
    • /
    • v.9 no.3
    • /
    • pp.261-266
    • /
    • 2000
  • A kinetic study for nitrate removal by anion exchange resin was performed using continuous column reactors. Kinetic approach from the packed bed showed the reaction rate constant k$_1$ was 0.07~0.17 $\ell$/mgㆍhr and maximum exchange quantity q$_{o}$ was 27.75~31.81 mg/g. The results from the continuous column well agreed with that from the batch reactor. An economic analysis of the water treatment plant by anion exchange resin with a regenerating system was performed to design plant and process. Based on the treatment of 20 mg/$\ell$ nitrate-contained wastewater of 10,000 gallons per day to 2 mg/$\ell$, total capital cost and total annual cost are estimated to be 836 million wons and 211 million wons, respectively.y.

  • PDF

Comparison of Seawater Exchange Rate of Small Scale Inner Bays within Jinhae Bay (수치모델을 이용한 진해만 내 소규모 내만의 해수교환율 비교)

  • Kim, Nam Su;Kang, Hoon;Kwon, Min-Sun;Jang, Hyo-Sang;Kim, Jong Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.1
    • /
    • pp.74-85
    • /
    • 2016
  • For the assessment of seawater exchange rates in Danghangpo bay, Dangdong bay, Wonmun bay, Gohyunsung bay, and Masan bay, which are small-scale inner bays of Jinhae bay, an EFDC model was used to reproduce the seawater flow of the entire Jinhae bay, and Lagrange (particle tracking) and Euler (dye diffusion) model techniques were used to calculate the seawater exchange rates for each of the bays. The seawater exchange rate obtained using the particle tracking method was the highest, at 60.84%, in Danghangpo bay, and the lowest, at 30.50%, in Masan bay. The seawater exchange rate calculated based on the dye diffusion method was the highest, at 45.40%, in Danghangpo bay, and the lowest, at 34.65%, in Masan bay. The sweater exchange rate was found to be the highest in Danghangpo bay likely because of a high flow velocity owing to the narrow entrance of the bay; and in the case of particle tracking method, the morphological characteristics of the particles affected the results, since once the particles get out, it is difficult for them to get back in. Meanwhile, in the case of the Lagrange method, when the particles flow back in by the flood current after escaping the ebb current, they flow back in intact. However, when a dye flows back in after escaping the bay, it becomes diluted by the open sea water. Thus, the seawater exchange rate calculated based on the dye diffusion method turned out to be higher in general, and even if a comparison of the sweater exchange rates calculated through two methods was conducted under the same condition, the results were completely different. Thus, when assessing the seawater exchange rate, more reasonable results could be obtained by either combining the two methods or selecting a modeling technique after giving sufficiently consideration to the purpose of the study and the characteristics of the coastal area. Meanwhile, through a comparison of the degree of closure and seawater exchange rates calculated through Lagrange and Euler methods, it was found that the seawater exchange rate was higher for a higher degree of closure, regardless of the numerical model technique. Thus, it was deemed that the degree of closure would be inappropriate to be used as an index for the closeness of the bay, and some modifications as well as supplementary information would be necessary in this regard.

The Exchange of Sea Water in Yeoja Bay (여자만의 해수교환)

  • 이명철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.33-39
    • /
    • 1983
  • Tidal exchange of sea water was studied by using drogue experiments and tidal current measurement data in Yeoja Bay which has a narrow channel. At the spring tide, the volume of tidal transport in the bay was estimated to be 43% of the mean volume of the sea water in Yeoja Bay, 1.96km super(3). Residual current was deduced to flow southward at the rate of 3,658$\times$10 super(4) m super(3) per tidal cycle. The mean tidal exchange of sea water during the flood flow was estimated to be approximately 5.0% of the volume of sea water at the mean high water level in the bay, 2.33km super(3), while that during the ebb flow was 6.3%. One dimensional diffusion coefficient of 1.69-1.97$\times$10 super(6) cm super(2)/sec was obtained at the channel in the bay.

  • PDF

Enhancement of Hydroxylamine Reactivity of Bacteriorhodopsin at High Temperature

  • Sonoyama, Masashi;Mitaku, Shigeki
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.299-301
    • /
    • 2002
  • Recent denaturation experiments of bacteriorhodopsin (bR) in the dark and under illumination at high temperatures revealed that irreversible thermal bleaching occurs above ~ 70°C and the preceding reversible structural changes in the dark above 60°C are closely related to irreversible photobleaching observed in the same temperature range (Yokoyama et al. (2002). J Biochem. 131,785). In this study, structural properties of bacteriorhodopsin (bR) at high temperatures were extensively probed by hydroxylamine reactivity with the Schiff base in the dark and hydrogen-deuterium (H-D) exchange in the peptide groups. In the Arrhenius plot from kinetics measurements of the hydroxylamine reaction, a good linear relationship between the reaction time constant and the inverse of the absolute temperature was observed below 60°C, while significant increase started above 60°C, suggesting that remarkable increase in water accessibility of the Schiff base in the temperature region. FT-IR spectroscopic studies on the H-D exchange suggested increase in the deuterium exchanges rate of the peptide hydrogen in the same temperature region.

  • PDF

The Effects of Blouse Types on Ventilation Clothing Microclimate (블라우스내에 형성되는공기층이 의복내환기에 미치는 영향 연구)

  • Park Woo Mee;Choi Chul Ho
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.169-180
    • /
    • 1992
  • The purpose of this study is to investigate the effects of type of clothing microclimate and exercise condition on ventilation. The experimental system employed a trace gas technique of the previous research. Clothing microclimate volume measurement was based on the substitution water technique for inter-clothing air volume. The experimental variables were tested at four levels of clothing microclimate spacing, microclimate shape of the previous research and two levels of exercise conditions. 2, 4, 6 cm ease were added to B/2+4 of basic blouse pattern for the microclimate spacing variable. Each combination of three variables were tested in triplicate. Analysis of variance of experimental variables on vetilation, such as oxygen exchange rate, half time of first order model was conducted. Oxygen exchange rate and half time of first order model are affected by the shape of microclimate air and exercise condition.

  • PDF

A Study on the Characteristic and Preparation of PEM for DMFC using EPS, SAN, HIPS (EPS, SAN, HIPS를 이용한 직접 메탄올 연료전지용 고분자 전해질 막의 제조 및 그 특성에 관한 연구)

  • Song, Ju-Yeong;Kim, Hi-Youl;Kim, Jong-Hwa;Lee, Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • In this study, we prepared porous cation exchange membrane using polystyrene such as, EPS (expanded polystyrene), SAN (styrene acrylonitrile copolymer) and HIPS (high impactive polystyrene). These polystyrenes were sulfonated by acetyl sulfate to make porous cation exchange membrane such as, SEPS, SSAN, SHIPS. SEM was employed to confirm porous structure of membrane, and IR spectroscopy was used to confirm sulfonation rate of ion exchange membrane. Water and methanol content were also increased with amount of sulfuric acid in reactants. SSAN-20 showed the highest value in water and methanol content. Fixed ion concentration and conductivity was also increased with an amount of sulfuric acid in reactants. Methanol permeability for SEPS-20, SSAN-20, SHIPS-20 was found to be $1.326\;{\times}\;10^{-5}\;cm^2/s$, $1.527\;{\times}\;10^{-5}\;cm^2/s$ and $1.096\;{\times}\;10^{-5}\;cm^2/s$ respectively. From the result of electrodialysis experiment in 0.03 M $Pb(NO_3)_2$ aqueous solution, anion exclusion and cation selection effects were confirmed.

Enhanced ion-exchange properties of clinoptilolite to reduce the leaching of nitrate in soil

  • Kabuba, John
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.41-52
    • /
    • 2022
  • The leaching of nitrate from soil increases the concentration of elements, such as nitrogen, phosphorus, and potassium, in water, causing eutrophication. In this study, the feasibility of using clinoptilolite as an ion-exchange material to reduce nitrate leaching in soil was investigated. Soil samples were collected from three soil depths (0 - 30, 30 - 90, and 90 - 120 cm), and their sorption capacity was determined using batch experiments. The effects of contact time, initial concentration, adsorbent dosage, pH, and temperature on the removal of NO3- were investigated. The results showed that an initial concentration of 25 mg L-1, a contact time of 120 min, an adsorbent dosage of 5.0 g/100 mL, a pH of 3, and a temperature of 30 ℃ are favorable conditions. The kinetic results corresponded well with a pseudo-second-order rate equation. Intra-particle diffusion also played a significant role in the initial stage of the adsorption process. Thermodynamic studies revealed that the adsorption process is spontaneous, random, and endothermic. The results suggest that a modification of clinoptilolite effectively reduces the leaching of nitrate in soil.

Thermal Management of Proton Exchange Membrane Fuel Cell (고분자막전해질 연료전지의 열관리)

  • Yu, Sang-Seok;Kim, Han-Seok;Lee, Sang-Min;Lee, Young-Duk;Ahn, Kook-Young
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.3
    • /
    • pp.292-300
    • /
    • 2007
  • A dynamic system model of a proton exchange membrane fuel cell(PEMFC) has been developed. The PEMFC of this study has large active area with water cooling in order to simulate the performance of the commercially viable PEMFC system for the transportation. A PEMFC stack model is a transient thermal model which is respond to the dynamic change of the coolant temperature and the flow rate. The dynamic cooling system model has been developed to determine the coolant flow rate and the coolant temperature. Prior to the system level study, thermal management criteria have been set up and brought to the control command of the cooling system. Since the system model is designed to evaluate the effect of thermal management on the system performance, it is attempted to determine the proper control algorithm of the cooling system so that the PEMFC system is working on the thermal management criteria. As a result of simulation, feedback controlled cooling system consumes less power and produce more power comparing with that of conventionally controlled cooling system.

Acid green-25 removal from wastewater by anion exchange membrane: Adsorption kinetic and thermodynamic studies

  • Khan, Muhammad Imran;Ansari, Tariq Mahmood;Zafar, Shagufta;Buzdar, Abdul Rehman;Khan, Muhammad Ali;Mumtaz, Fatima;Prapamonthon, Prasert;Akhtar, Mehwish
    • Membrane and Water Treatment
    • /
    • v.9 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • In this work, batch adsorption of anionic dye acid green-25 (AG-25) from aqueous solution has been carried out at room temperature using anion exchange membrane (DF-120B) as a noval adsorbent. The effect of various experimental parameters such as contact time, membrane dosage, ionic strength and temperature on the adsorption of dye were investigated. Kinetic models namely pseudo-first-order, pseudo-second-order, Elovich, liquid film diffusion, Bangham and modified freundlich models were employed to evaluate the experimental data. Parameters like adsorption capacities, rate constant and related correlation coefficients for every model are calculated and discussed. It showed that adsorption of AG-25 onto DF-120B followed pseudo-first-order rate expression. Thermodynamic study indicates that adsorption of AG-25 onto DF-120B is an exothermic and spontaneous process.