• 제목/요약/키워드: Water environment service

검색결과 334건 처리시간 0.034초

무기계 방오(防汚)제가 혼입된 콘크리트 특성에 관한 실험적 연구 (Experimental Study on Properties of Concrete Incorporating Inoragnic Antifouling Agent)

  • 김연봉;남재현
    • 한국건축시공학회지
    • /
    • 제5권2호
    • /
    • pp.97-105
    • /
    • 2005
  • Concrete structures in the marine environment often deteriorate in the early stage of their service life because of contact with various aggressive conditions. In recent years, the researches on the concrete in the marine environment have been carried out to increase their service life. In this experimental study, the concrete specimens were prepared with various adding contents of inorganic antifouling agent$(0\~3.0wt\%)$ composed of some fluosilicate solution. For evaluation of the properties of concretes containing inorganic antifouling agent, various tests such as setting time, slump loss, compressive strength, water absorption rate, fleering and thawing resistance and SEM of concrete, were conducted. As the results, physical and chemical properties of concretes were improved with an adding of inorganic antifouling agent. From the results of various tests, the optimal adding contents of antifouling agent was $1.0wt\%$.

Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석 (Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector)

  • 홍인석;최윤화;권택부;이정학
    • 한국동물위생학회지
    • /
    • 제28권3호
    • /
    • pp.285-294
    • /
    • 2005
  • This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

High Strength Low Alloy Steel for Sour Service

  • Jung, Hwan Gyo;Kim, Sang Hyun;Yang, Boo Young;Kang, Ki Bong
    • Corrosion Science and Technology
    • /
    • 제7권5호
    • /
    • pp.288-295
    • /
    • 2008
  • The increase use of natural gas as an energy source has been continuous demand for ever-increasing strength in gas transmission pipeline materials in order to achieve safe and economic transportation of natural gas. In particular, linepipe material for sour gas service primarily needs to have crack resistant property. However, applications of sour linepipes are expanding toward deep water or cold region, which require higher toughness and/or heavier wall thickness as well as higher strength. To improve the crack resistance of linepipe steel in sour environment, low alloy steel are produced by controlled rolling subsequently followed by the accelerated cooling process. This paper summarizes the design concepts for controlling crack resistant property low alloy linepipe steels for sour gas service.

수환경 적응도에 따른 식물 목록 구축 및 도시 수 공간에 적용 가능한 식물 분류특성 (Inventory Development according to Aquatic Environment Fitness and Classification Characteristics of Plants for Urban Water Space)

  • 이란;권효진;김형국;박미옥;구본학;최일기
    • 한국환경복원기술학회지
    • /
    • 제16권2호
    • /
    • pp.93-104
    • /
    • 2013
  • The purpose of this study was to develop a list of plants that adapted to the aquatic environment in urban areas based on the list of plants surveyed through literature review and field surveys, and to classify the types of vegetation according to the five categories of plant distributions set by the U.S. Fish and Wildlife Service (1988) in the aspect of the adaptability of plants to the aquatic environment. Results of the classification by category according to the adaptability to the aquatic environment for the plant species surveyed through literature review and field surveys showed that there are 45 species of OBL, 96 species of FACW, 66 species of FAC, and 94 species of FACU, totaling 650 species. In addition, a total of 50 species excluding exotic species, endangered species, and naturally introduced plants are proposed as appropriate plants for the urban aquatic environment that will be artificially constructed. The results of the study can be utilized as the basic information for maintaining diversity and stability of the ecosystem during the restoration of water ecology; they can serve as useful data for the development of an optimum vegetation model when planting in water spaces in the future and preparing proper planting plans for each space. In addition, it is believed that the information will be useful in wetland identification and evaluation by observing plant species that appear only in wetlands.

우리나라 논 관개용 지하수 수질 특성 (Characteristics of the Groundwater Quality for Paddy Fields in Korea)

  • 김진호;조광래;임수정;이경자;경기천;엄미정;김희권;김찬용;이영한;이신찬;윤순강
    • 한국환경농학회지
    • /
    • 제22권4호
    • /
    • pp.241-245
    • /
    • 2003
  • This study was carried out to evaluate the status of the groundwater quality for paddy fields irrigation in Korea. Water samples were collected at 130 sites throughout the country. Samples were collected at three seasons - April, July and October - in 2000. According to our survey, the groundwater was found to be suitable for irrigation purpose. Average EC was shown 0.286 dS/m. Nitrate-nitrogen and $Cl^-$ concentration was 5.6 mg/L, 32.95 mg/L which satisfied the Korean Standards for Irrigation Water. Nitrate-nitrogen concentration in each province was shown as following orders: Jeju (11.17 mg/L) > Chungnam (8.16 mg/L) > Gyeongbuk (6.64 mg/L) > Gyounggi (5.91 mg/L) > Chungnam (4.95 mg/L) > Gyeongnam (3.91 mg/L) > Jeonbuk (3.50 mg/L) > Jeonnam (3.27 mg/L) > Gangwon (2.91 mg/L). The concentration by sampling seasons were October (6.62 mg/L) > July (5.88 mg/L) > April (4.78 mg/L). As the soil of Jeju Province is usually derived from volcanic ash soils mainly used for upland drops, it may influence the nitrate-nitrogen concentration of groundwater. The amount of rainfall also influence the water quality. But the $COD_{Cr}$ were shown April (3.17 mg/L) > July (2.91 mg/L) > October (2.40 mg/L), it is highly related in the basal dose of organic matter fertilizers. This study demonstrated that groundwater quality was suitable for irrigation, but continuous monitoring is recommended for agricultural policy and developing OECD agricultural environment indicators.

남한강 보 구간 유수성 저서성 대형무척추동물의 시·공간적 분포 특성 (Spatio-temporal Distribution Patterns of Lotic Benthic Macroinvertebrate Communities in Namhan-River Weir Section)

  • 김진영;이승현;이경락;노성유;신유나;이수웅;이재관;원두희;임성호;권용주;공동수
    • 생태와환경
    • /
    • 제51권4호
    • /
    • pp.331-344
    • /
    • 2018
  • 한강수계 남한강의 보(강천보, 여주보, 이포보) 공사 후 수변부 여울 구간의 물리적 환경의 변화에 따른 유수성 저서동물의 군집 변화를 확인한 결과 다음과 같은 결론을 얻었다. 첫째, 보에 의한 여울구간의 소실은 유속, 하상 등 물리적 환경의 변화를 야기하여 수질요인과는 독립적으로 수생태계에 영향을 미칠 수 있다. 둘째, 남한강 보 구간의 수변부 물리적 서식환경의 복합적인 변화는 유수성 분류군의 군집구성에 영향을 미친 것으로 판단된다. 셋째, 저서성 대형무척추동물 유수성 지표 후보종 157 분류군은 수생태계 변화의 원인 분석을 비롯한 하천 수생태계 복원 및 재자연화 등에 유용한 지표로 활용될 수 있을 것으로 기대된다. 넷째, 향후 유속변화에 대한 수생태계 영향을 면밀하게 파악하기 위해서는 분류군별 유속에 대한 저항성 또는 선호도를 바탕으로 한 지표연구가 필요할 것으로 사료된다.

돌말(Epilithic Diatom) 지수를 이용한 국내 주요 하천(금강, 영산강, 섬진강)의 생물학적 수질평가 (Biological Assessment of Water Quality by Using Epilithic Diatoms in Major River Systems (Geum, Youngsan, Seomjin River), Korea)

  • 황순진;김난영;원두희;안광국;이재관;김창수
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.784-795
    • /
    • 2006
  • The purpose of this study was to assess biological river water quality by using epilithic diatoms at 40 selected sites in Geum, Youngsan, and Seomjin River systems. The sampling and analyses were performed during three seasons including January, April and June in 2005. Various water quality parameters also were analyzed. We attempted to classify the water quality condition by epilithic diatom indices (DAIpo and TDI) with the results of corresponding analyses of various chemical water quality parameters. A five class system was delivered to describe the water quality condition ranged from "very good" to "very poor." We also proposed a way of classifying water quality condition by combining two diatom indices of DAIpo and TDI. Our results showed that biomass of epilithic diatoms varied not only seasonally but spatially; it was not likely that winter diatoms represent average water quality condition, due to high concentration of nutrients. Water quality status assessed by diatom indices was generally worse than that assessed by BOD, indicating that BOD standard likely underestimates the biological condition of the water body. Importantly, nutrient-based diatom index (TDI) generally overestimated organic matter-based index (DAIpo) at most study sites, indicating that diatoms in studied rivers were likely more affected by nutrients than organic matter. Thus, management strategy to improve river water quality in Korea is suggested to emphasize more on the nutrients than organic matters.

교육시설 내용년한 산정 연구 - 옥상방수와 바닥마감재를 대상으로 - (Establishment of the Service Life of the Education Fcilities - Focused on the Roof water-proof and Floor finishings -)

  • 이강희;채창우
    • 교육시설 논문지
    • /
    • 제24권6호
    • /
    • pp.27-36
    • /
    • 2017
  • Educational facilities have an affect to make a decently learning environment. After constructed, it needs a maintenance plan to keep the performance or function which provide the repair time, repair scope and ratio. But the fundamental data are so insufficient that the field worker can't provide the maintenance plan and has no choice use the other data which concerned with apartment or office building. Above all, the service life is indispensible to make a repair plan because the repair time and scope would be provided within the service life. This study aimed at providing the method to make a service life of component in educational facilities and applying the method into the roof proof and floor finishing. Results are shown that first, it is important to set the $1^{st}$ repair time after constructed. when it proposes the three ways with the probability approach, choice probability model and cumulative cost function. Second, the service life of roof proof is provided with about 35 years. In addition, the service life of the floor finishing is about 40 years. These result would be utilized to conduct the repair plan under the service life.

A Study of Soil Moisture Retention Relation using Weather Radar Image Data

  • Choi, Jeongho;Han, Myoungsun;Lim, Sanghun;Kim, Donggu;Jang, Bong-joo
    • Journal of Multimedia Information System
    • /
    • 제5권4호
    • /
    • pp.235-244
    • /
    • 2018
  • Potential maximum soil moisture retention (S) is a dominant parameter in the Soil Conservation Service (SCS; now called the USDA Natural Resources Conservation Service (NRCS)) runoff Curve Number (CN) method commonly used in hydrologic modeling for event-based flood forecasting (SCS, 1985). Physically, S represents the depth [L] soil could store water through infiltration. The depth of soil moisture retention will vary depending on infiltration from previous rainfall events; an adjustment is usually made using a factor for Antecedent Moisture Conditions (AMCs). Application of the method for continuous simulation of multiple storms has typically involved updating the AMC and S. However, these studies have focused on a time step where S is allowed to vary at daily or longer time scales. While useful for hydrologic events that span multiple days, this temporal resolution is too coarse for short-term applications such as flash flood events. In this study, an approach for deriving a time-variable potential maximum soil moisture retention curve (S-curve) at hourly time-scales is presented. The methodology is applied to the Napa River basin, California. Rainfall events from 2011 to 2012 are used for estimating the event-based S. As a result, we derive an S-curve which is classified into three sections depending on the recovery rate of S for soil moisture conditions ranging from 1) dry, 2) transitional from dry to wet, and 3) wet. The first section is described as gradually increasing recovering S (0.97 mm/hr or 23.28 mm/day), the second section is described as steeply recovering S (2.11 mm/hr or 50.64 mm/day) and the third section is described as gradually decreasing recovery (0.34 mm/hr or 8.16 mm/day). Using the S-curve, we can estimate the hourly change of soil moisture content according to the time duration after rainfall cessation, which is then used to estimate direct runoff for a continuous simulation for flood forecasting.

운영형태별 수도사업 생산성 평가 (An evaluation of local waters productivity by operating types)

  • 김상문;이익규
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.325-334
    • /
    • 2011
  • Market Environment around water work industry is rapidly changing. ISO, International Organization for Standardization, announced the international water work service standard for comparison and evaluation between nations and businesses. And developed countries in water work are introducing market principle for growth of nation's water industry and reinforcement of its competitiveness. Also, some local governments entrusted their water utilities for improvement of competitiveness of water work. However, as some failure cases from overseas came out with emphasis, there are many refuting perspective about entrusted operation achievements of domestic water market. Hence, this paper evaluated competitiveness of domestic local water utilities from the perspective of productivity. After evaluating productivity using Malmquist productivity index, the authors compared and analyzed whether there is a difference of productivity between two different operating types by using Mann-Whitney test. As a result of analysis, it has shown that local water utilities achieved higher productivity at entrusted operation type rather than direct operation type. The local water utilities which chose entrusted operation had increased the productivity 13.9% on total factor productivity(TFP) during experimenting period, while the local water utilities which chose direct operation had increased 0.2%. The background of achieving this high productivity in entrusted operation was analyzed as a result of the higher technological effectiveness of a special water company. The result of this study can be referred when local government needs to decide on what operating types they will use.