Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

Investigation of Pitting Corrosion of Copper Heat-Return Pipe in District Heating (지역난방 구리난방환수관의 공식 원인 분석)

  • Keun Hyung Lee;Min Ji Song;Tae Uk Kang;Woo Cheol Kim;Heesan Kim;Soo Yeol Lee
    • Corrosion Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.315-323
    • /
    • 2024
  • This work examined pitting corrosion failure of a copper heat-return pipe used in a district heating system. The copper pipe was corroded with a 48% reduction in thickness due to localized corrosion on the inner surface exposed to heating water of 20 ~ 40 ℃. Fe and Si elements as corrosion products were found around pits. Cl element was also observed, which accelerated oxidation of copper inside pits. Cu2O deposits on the pit's bottom surface decreased the pH inside the pit. X-ray diffraction analysis revealed hematite, cuprite, malachite and brochantite as corrosion products. Chemical analysis demonstrated that Fe and Si elements did not exist in the copper, supply water, or heating water, indicating that Fe and Si species might have entered into the pipe from the exterior. These results indicated that pits were initiated due to ion concentration gradient near Fe and Si species. Moreover, the interior of pits had lower pH due to Cl- concentration and Cu2O reactions, which accelerated the pit's growth and led to formation of pinholes. Additionally, we confirmed that the type of pitting corrosion was a complex combination of types I and II based on the HCO3-/SO42- ratio, pH, temperature, and corrosion products.

A Study on the Integrated Fusion Technology Between a Carbon Dioxide Emission and a District Cooling Energy Using a Cold Energy ($CO_2$ 배출문제와 냉열이용 지역집단 냉방에너지에 관한 통합적 융합기술 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.34-40
    • /
    • 2006
  • This paper provides a fusion technology between a district cooling energy system and an environment conservation policy based on the energy savings and reusable cold energy resources. The district heating and cooling systems are very effective ways for an energy saving, a cost reduction and a safety control. It is necessary to equalize the energy savings and an environmental preservation policy for an improved human lift. A gasification process of a liquefied natural gas, cooling water from deep seawater and an ice water thermal storage system may produce a cold energy. A district cooling system is used to cool an apartment, office buildings and factory facilities with a cooling energy supply pipeline. LNG cooling energy will switch a conventional air-conditioning system, which is operated by on electrical energy and a Freon refrigerant. Coincident with significant clean energy and operating cost savings, LNG cold energy system owen radical reductions in an air-borne pollutant, $CO_2$ and the release of environmentally harmful refrigerants compared with that of the conventional air-conditioning system. This study provides useful information on the fusion technology of a LNG cold energy usage and energy savings, and environmental conservation.

  • PDF

A Study on the Content of Manganese and Chrome in the Ground Water in Seoul Area (Based on non-water supply area) (서울 일부지역 정호수의 망간, 크롬함량 조사연구 상수시설 미설치지역을 중심으로)

  • 구성회;우세홍;이성호;이부웅
    • Journal of Environmental Health Sciences
    • /
    • v.1 no.1
    • /
    • pp.41-45
    • /
    • 1974
  • A study was carried out to determine the content of Mn and Cr in the ground water in Seoul area, where municipal water supply system was not installed, from Nov. 1 to Nov. 30, 1973. In this study, authors examined the hardness, pH, water temperature and Cl ion to investigate the general conditions of the ground water. For this study, samples were collected from 46 wells which were located in outpart of Seoul city, and Mn and Cr were determined with the Spectronic-20. The following results were obtained: 1) Average value of the ground water conditions of the wells were 13.3$\circ$C in temperature, pH 6.3, hardness 159 ppm and Cl ion 41 ppm. 2) In the manganese concentration, the highest area was Yeongdeungpo-Ku(0.318 ppm), while the lowest area was Sungbuk-Ku(0.065 ppm) and the mean concentration of the whole district was 0.196 ppm. 3) In the chrome concentration, the highest area was Yeongdeungpo-Ku(0.031 ppm), while the lowest area was Dobong-Ku (trace) and the mean concentration of the whole district was 0.012 ppm.

  • PDF

Use of Ferrous and Ferric Coagulants To Reduce Bromate and Particulate Levels (입자상 물질 및 Bromate의 저감을 위한 철염응집제의 이용)

  • Krasner Stuart-W;Yates Richard-S;Amy Gary;Garside Jason
    • 수도
    • /
    • v.24 no.4 s.85
    • /
    • pp.39-46
    • /
    • 1997
  • 실험실 규모의 연구를 확대한 Pilot-Plant연구는 Bromate 감소에 대한 다양한 수질 문제에 대응할 수 있었다. 이러한 연구를 통해 산성하에서 $Fe^{2+}$을 주입시 Bromate가 감소됨을 확인하였다. 그러나 이러한 반응은 느린 반응이었으며, 온도에 의존하는 반응이었다. 단독응집제로서 $Fe^{2+}$은 탁도를 증가시켰다. 따라서 탁도를 제어하기 위해 $Fe^{2+}$를 주입하였다. $Fe^{2+}$/$Fe^{3+}$응집제의 조합으로 TOC를 제거할 수 있었다. 초기 결과를 통해 이러한 공정은 매우 면밀히 추진되어야 하며, 모든 온도에서 적용될 수 없었다. 현재까지 얻어진 결과에 의하면 오존처리함으로서 발생되는 Bromate를 최소화하는 방안은 낮은 pH조건과 $Fe^{2+}$의 주입이다. 최종 처리수에서 입자상물질과 철을 최소화하기 위해서는 pH 등과 같은 조건들을 변화시켜 여과공정 이전에 잔류 $Fe^{2+}$를 산화시킬 수 있도록 초기에 최적화가 이루어 져야 한다.

  • PDF

Experimental Study on the Drag Reduction & Heat Transfer Ratio in the Circular Pipe with Swirl Generater (난류발생기를 가지는 원형 파이프내에서의 마찰저감 및 열전달율에 관한 실험적 연구)

  • Kim, Seong-Su;Cho, Sung-Hwan;Yoon, Seok-Mann
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.430-435
    • /
    • 2008
  • Total lengths of domestic pipe network for district heating system are above about 2,500Km. A lots of pumping power for heat transportation through long pipe are required by the flow friction of pipe surface. Until now there have been considered about various methods to reduce the flow friction for district heating system such as using surfactants and turbulence promoters by swirl flow and baffles etc. At this study, swirl flow generator was tested about the possibility to increase the heat transfer ratio at the heat exchanger in the case which the suppling water temperature increased from $50^{\circ}C$ until $120^{\circ}C$. Experimental results showed that the heat transfer ratio increased and also pressure increase ratio increased simultaneously in the case which swirl flow generator installed. The amount of the increasing ratio for heat transfer and pressure were reached until 4.33% and 11% at the case of $120^{\circ}C$ suppling temperature which domestic district heating system were using.

  • PDF

Solar District Heating System (지역난방용 태양열시스템)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yoon, Eung-Sang;Yoon, Suk-Man;Sin, U-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

Characteristics of Irrigation on Yi-dong Agricultural Water District (이동 농업용수지구 관개특성)

  • 김진택;이용직
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2003.05a
    • /
    • pp.62-65
    • /
    • 2003
  • Improvement of the efficiency of the agricultural water use is important for the sustainable water management because the agricultural water use occupied above 60% of the total water use in korea. For the analysis of agricultural water use the Yi-dong experimental site was selected. For the monitoring system of the experimental site, four rainfall gauging stations and twenty-six water level gauging stations are established and operated. Analyses of the measured data are processed for the irrigation efficiency of agricultural water on the eight irrigation areas.

  • PDF

Managing Groundwater Resources in New Zealand to Account for Environmental Change

  • Davidson, Peter William
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.40-45
    • /
    • 2007
  • Water regulators in New Zealand have recognised the need to adapt water allocation regimes and water permit conditions to reflect the likelihood of lower catchment yield on the east coast from 2030 due to climate change. Water management mechanisms to protect the environment and maintain the reliability of other water users are currently being applied or assessed in Marlborough province. These include seasonal water quota based on spring aquifer status, linking water use to environmental triggers to avoid seawater intrusion or spring depletion; and redefining water permit entitlements to account for recharge variability.

  • PDF

Characteristics of Irrigation Return Flow in a Reservoir Irrigated District (저수지 관개지구의 농업용수 회귀 특성 분석)

  • Song, Jung Hun;Song, Inhong;Kim, Jin-Taek;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.69-78
    • /
    • 2015
  • The objective of this study was to investigate characteristics of irrigation return flow from paddy block in a reservoir irrigated district during growing seasons. The irrigation return flow was divided into three parts, quick return flow from irrigation canal (RFI), quick return flow from drainage canal (RFD), and delayed return flow (DRF). The RFI was calculated from water level and stage-discharge relationships at the ends of the irrigation canals. The DRF was estimated using measured infiltration amount from paddy fields of the irrigated district. A combined monitoring and modeling method was used to estimate the RFD by subtracting surface runoff from surface drainage. The paddy block irrigated from the Idong reservoir was selected to study the irrigation return flow components. The results showed that daily agricultural water supply (AWS), the RFI, and the RFD were $27.4mm\;day^{-1}$, $4.9mm\;day^{-1}$, and $19.8mm\;day^{-1}$, respectively in May, which were greater than other months (p<0.05). The return flow ratio of the RFI and the RFD were the greatest in July (34.6%) and May (72.3%), respectively. The daily AWS was closely correlated with the RFD (correlation coefficients of 0.76~0.86) in except for July with, while correlation coefficient with the RFI were 0.56 and 0.42 in June and July, respectively (p<0.01). The total irrigation return flow was 1,965 mm in 2011, and 1,588 mm in 2012, resulting in total return flow ratio of 84.6% and 79.1%, respectively. This results indicate that substantial amounts of agricultural water were returned to streams as irrigation return flow. Thus, irrigation return flow should be fully considered into the agricultural water resources planning in Korea.