• 제목/요약/키워드: Water district

검색결과 597건 처리시간 0.025초

관개용수로에서의 수면곡선 계산 (Water Surface Profile Computations at Irrigation Channel Networks)

  • 김현준;박승우
    • 한국농공학회지
    • /
    • 제30권3호
    • /
    • pp.114-120
    • /
    • 1988
  • A water surface profile computation model using a standard step procedure was developed for gradually varied flow at an irrigation channel network. Flow characteristics ab Banweol district near Suweon were field monitored during irrigation periol of 1987. The model was applied to the main system at the district and the simulation results were compared to the field data. The results are sumrnarized as follows ; 1. The simulated water surface profiles from the model were in good agreement with the measured water surface profiles at different flow rates. 2. The model applicability for defining a stage-discharge relationship at a channel reach was demonstrated with reasonable accuracy when water stage and friction factor were given. 3. The roughness coefficient was found to be a major factor sigrificantly affecting computed water surface profile among a few physical input parameters for the model.

  • PDF

양수저류시스템의 반복이용률 측정 (Measurement of Irrigation water-reuse ratio for pumped storage system)

  • 박지성;김영화;이영일;김필동
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.295-298
    • /
    • 2003
  • In this study, It classified type of irrigation water development in islands district. As result, the types which were type of reservior, fleshwater lake, pumped storage, ets. Most of islands district has developed reuse irrigation system as a pumped storage system. But, Irrigation water-reuse ratio doesn't define a basis clearly and the value of measurement for water-reuse ratio doesn't exist so far. so, we measured Irrigation water-reuse to clarify for water-reuse ratio in a pumped storage system.

  • PDF

인버터시스템 적용 지역난방 시스템의 2차측 공급수 온도 제어방안에 따른 에너지사용량 실증 비교 (Actual Energy Consumption Analysis of Temperature Control Strategies for Secondary Side Hot Water District Heating System with an Inverter)

  • 조성환;홍성기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.179-186
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side District Heating System (DHS) with different hot water supply temperature control methods is compared. The two methods are Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side system, the results show that the Outdoor Temperature Predictive Control method saves more energy. In general, the Outdoor Temperature Predictive Control method lowers the supply temperature of hot water, and it reduces standby losses and increases the overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, the Outdoor Temperature predictive Control method saves about 6.6% of energy when compared to the Outdoor Temperature Reset Control method. Also, it is found that at partial load condition, such as during daytime, the fluctuation of hot water supply temperature with Outdoor Temperature Reset Control is more severe than that with Outdoor Temperature Predictive Control. Thus, it proves that Outdoor Temperature Predictive Control is more stable even at partial load conditions.

지역난방 첨두부하보일러 대류부 부식 파손 분석 (Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler)

  • 김영수;채호병;홍민기;송민지;조정민;김우철;하태백;이수열
    • Corrosion Science and Technology
    • /
    • 제18권2호
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

Assessing the Spatial Distribution of Perfluorooctanoic Acid Exposure via Public Drinking Water Pipes Using Geographic Information Systems

  • Vieira, Veronica;Hoffman, Kate;Fletcher, Tony
    • Environmental Analysis Health and Toxicology
    • /
    • 제28권
    • /
    • pp.9.1-9.5
    • /
    • 2013
  • Objectives Geographic Information Systems (GIS) is a powerful tool for assessing exposure in epidemiologic studies. We used GIS to determine the geographic extent of contamination by perfluorooctanoic acid, C8 (PFOA) that was released into the environment from the DuPont Washington Works Facility located in Parkersburg, West Virginia. Methods Paper maps of pipe distribution networks were provided by six local public water districts participating in the community cross-sectional survey, the C8 Health Project. Residential histories were also collected in the survey and geocoded. We integrated the pipe networks and geocoded addresses to determine which addresses were serviced by one of the participating water districts. The GIS-based water district assignment was then compared to the participants' self-reported source of public drinking water. Results There were a total of 151,871 addresses provided by the 48,800 participants of the C8 Health Project that consented to geocoding. We were able to successfully geocode 139,067 (91.6%) addresses, and of these, 118,209 (85.0%) self-reported water sources were confirmed using the GIS-based method of water district assignment. Furthermore, the GIS-based method corrected 20,858 (15.0%) self-reported public drinking water sources. Over half (54%) the participants in the lowest GIS-based exposure group self-reported being in a higher exposed water district. Conclusions Not only were we able to correct erroneous self-reported water sources, we were also able to assign water districts to participants with unknown sources. Without the GIS-based method, the reliance on only self-reported data would have resulted in exposure misclassification.

기후변화 대응방안 수립을 위한 농업용 저수지 이수안전도 평가 (An Irrigation Reliability Assessment of Agricultural Reservoir to Establish Response Plan of Future Climate Change Adaptation)

  • 권형중;남원호;최경숙
    • 한국농공학회논문집
    • /
    • 제62권2호
    • /
    • pp.111-120
    • /
    • 2020
  • This study assessed the reliability of the agricultural water supply based on future climate change scenarios, and suggested plans to improve the reliability in order to promote the adaptability of irrigation water in agricultural reservoirs to climate change. The assessment of agricultural water supply reliability was performed on reservoirs which had a lower water quantity than their design basis and which had recently been subject to drought. In other words, from the irrigation districts of main intake works among the reservoirs managed by the Korea Rural Community Corporation, 1~2 districts in each province-that is, a total of 13 districts -that were recently designated as a district for securing agricultural water (drought prevention district) were selected. Climate change scenarios were applied to the selected districts to analyze their future water supply reliability compared to the current level. All districts selected showed a drought frequency of 4 years or shorter, which demonstrated the need to establish climate change response plans. As plans for responding to climate change, a plan that utilizes supplemental intake works to reduce the area of the irrigation districts of main intake works, and another one that increases the capacity of main intake works were adopted to reanalyze their water supply reliability. When the area of the irrigation districts of main intake works was reduced by about 30~40%, the drought frequency dropped to more than 10 years, securing the reliability of water supply. To secure the reliability by increasing the capacity of main intake works, it was calculated that about 19,000~2,400,000 tons need to be added to each reservoir. In addition, climate change response plans were suggested to improve the reliability of the water supply in each district based on the results of economic analysis.

영산강 IV단계 사업지구 내 밭관개 실태조사 (Survey on current Farmer's Irrigation Practice on upland in the Youngsan River Irrigation Project District IV)

  • 윤광식;한국헌;최수명;김진태;이용직
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.287-290
    • /
    • 2003
  • To devise better development plan, survey was conducted about current Farmer's irrigation Practice on upland in the Youngsan River Irrigation Project District IV. Major upland crops are garlic and onion in this region. Currently, upland irrigation is conducted using ground water. It is found that irrigation interval is $2{\sim}3$ day for dry-field rice and $3{\sim}7$ days for other crop, in general. Whole day is required to irrigate for many farmers due to lack of facilities and water source. Farmers have no intention to change staple crops even after completion of Irrigation Project of Youngsan River District IV.

  • PDF