• Title/Summary/Keyword: Water contamination

Search Result 1,551, Processing Time 0.039 seconds

Water Quality Modeling and Environmantal Capacity in the Seom River Basin (섬강유역 환경용량 및 수질 Modeling)

  • 허인량;오근찬;최지용
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.80-86
    • /
    • 1998
  • Seom River was major branch of Namhan river, consist of primary basin that Wonjoo-city, Hoingsung-gun and primary contamination source was sewage from human lives. This study was evaluated production contamination loading of each branch basin and water quality grade and water quality simulation by QUAL2E to provide efficient contaminations source control. Rusult of survey, production loading of BOD, T-N, T-P were 26,591 kg/day, 4,560 kg/day, 731 kg/day resectively. Water quality analysis in 17 points of main stream were appeared that 1st grade(BOD 1 mg/l under) was 6 point, 2nd grade was 9 point and 3rd grade was 2 point. And result of water quality analysis for branch steram, first grade was evaluated 68.7%. Based of field data, calibration and verification result were in good agreement with mesured value within coefficient of variance were from 2.59% to 18.73%, from 6.39%, to 28.46%, respectively.

  • PDF

Quantification of Baseflow Contribution to Nutrient Export from a Agricultural Watershed (기저유출이 농업유역의 영양염류 유출에 미치는 영향 정량화)

  • Kim, Geonha;Yoon, Jaeyong;Park, Kijung;Baek, Jongrak;Kim, Youngjoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.347-357
    • /
    • 2015
  • Baswflow is defined as short term discharge through groundwater caused by rainfall events. Impacts of baseflow is significant on water quality especially where pervious agricultural watershed as groundwater is more vulnerable to the contamination. In this study, the Cheongmicheon watershed was subjected to study to assess the impacts of baseflow on surface water quality, where more than 90% of pollutant load is originated from the livestock raising area, and very high probability of surface water contamination due to the baseflow. To estimate nutrient loading cased by baseflow, NI (Numerical Integration) model and LOADEST (LOADing ESTimation) model were used.

Antibiotic and Heavy Metal Resistance of Coliform Bacteria Isolated from Mineral Water (약수에서 分離한 大腸菌群의 일부 중금속 및 抗生劑耐性에 관한 연구)

  • Jeong, Jee-Yeon;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.63-73
    • /
    • 1989
  • The purposes of this study were to find out the heavy metal and antibiotic resistant coliform bacteria from mineral water and the resistant factors. For the experiment, mineral water samples were taken from A area and B area during the period from march to July, 1988. The results of the experiment were as follows 1. From mineral water, eleven resistant coliforms and one susceptible coliform were isolated. 2. All resistant isolates harbored diverse plasmids of ranged ca. 14-54kb. 3. Susceptible coliform harbored a only plasmid of ca. 2.8 kb. 4. All resistant isolates harbored common size of plasmid of ca. 14kb. 5. As a result of the transformation and agarose gel electrophoresis experiments, resistant factor was R-plasmid. In conclusion, It is suggested that heavy metal contamination of mineral water is the selective pressure for the plasmid encoding the tolerance. Heavy metal resistance, in some case, is present with antibiotic resistance. Therefore, heavy metal contamination of mineral water induces antibiotic resistant bacteria.

  • PDF

EFFECT OF SURFACE CONTAMINATION ON THE TRANSVERSE STRENGTH OF THE RELINED DENTURE (첨상면 오염이 레진 의치상의 파절강도에 미치는 영향)

  • Kim, Jeong-Hyun;Bae, Jung-Soo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 1993
  • Autopolymerising and visible light cured resin are used to reline dentures. But relined surface are easily contaminated by water or saliva in the mouth during clinical procedure. This study was to find out the effect of surface contamination on the transverse strength of the relined denture base. To accomplish this, the specimens of $65\times10\times3mm$ were made with heat-cured(Lucitone 199), visible light-cured(Triad), and autopolymerizing resin(Kooliner). Measurements of transverse strength were taken for each specimen. Specimens made of heat-cured resins, sizing $65\times10\times1.5mm$, were relined with heat-cured, light-cured, and autopolymerizing resin, respectively. Specimens relined with autopolymerizing and light-cured resins were further classified into not-contaminated, water-contaminated and saliva-contaminated groups. Again, measurements of the transverse strength were taken for each group. The results were as follows 1. The transverse strength of heat-cured resin was superior to all the other resins. 2. The transverse strength of each specimen decreased after relining in the following order, heat-cured, visible light-cured, and autopolymerizing resin. 3. Surface contamination produced an decrease in transverse strength, especially in the saliva contaminated group. According to these results, water or saliva contamination should be avoided during intraoral relining procedures.

  • PDF

간장 효모에 대하여

  • 이한창
    • Korean Journal of Microbiology
    • /
    • v.1 no.1
    • /
    • pp.48-50
    • /
    • 1963
  • The authors have investigated about the microbial contamination of goods which is a criterion of hygienic control. Conducting on investigation, a special attention has been paid on the rate of microbial contamination in the goods, especially in manufacturing process of the softdrink. The authors also made an experiment on total microbes which is the criterion of contamination in each step of the process and in raw materials together with materials to be used for subdividing. Results obtained were as follows : 1) The orgin of microbial contamination was found in bottle cap and in tap water, that is, there appeared 9 colony per ml in bottle cap and 31-74 colony per ml in tap water, respectively. 2) It was found that microbial contamination are 4 colony per ml in average through year. However, it appeared 1 colony per ml in winter and 8 colony per ml in summer. 3) Coliform groups are not detected in goods through a year. 4) There was no variation in number of total microbes after ion exchange resin passage in purification process of tap water. 5) The number of microbes in goods are decreased when the raw materials are treated in high temperature short time (HTST) sterilization.

  • PDF

Groundwater Quality and Contamination Characteristics Associated with Land Use in Ulsan Area (울산지역 토지이용도에 따른 지하수 수질 및 오염특성)

  • Lee, Byeong-Dae;Yun, Uk;Sung, Ig-Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.78-91
    • /
    • 2007
  • The groundwater chemistry is heavily influenced by land use. This study has investigated the groundwater quality and contamination characteristic associated with land use. Contamination index ($C_d$) was estimated for evaluating and areal distribution of groundwater contamination degree. Groundwater samples collected from 216 locations in the study area show great variability in chemical composition. Electrical conductance ranges from 100 to $31,360\;{\mu}S/cm$. The pH values are between 4.6 (acidic) and 8.57 (weak alkaline). The water types predominantly represent the $Ca-HCO_3$ and $Ca-Na-HCO_3$ types, whereas, in the residential and business areas, the water type is shifted to (Na, Ca)-Cl type with rich concentration of Cl. The $C_d$ values of the study area range from 1.1 to 117.6 with a mean of 9.56.

A Study on the Statistical Predictability of Drinking Water Qualities for Contamination Warning System (수질오염 감시체계 구축을 위한 수질 데이터의 통계적 예측 가능성 검토)

  • Park, No-Suk;Lee, Young-Joo;Chae, Seonha;Yoon, Sukmin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.469-479
    • /
    • 2015
  • This study have been conducted to analyze the feasibility of establishing Contamination Warning System(CWS) that is capable of monitoring early natural or intentional water quality accidents, and providing active and quick responses for domestic C_water supply system. In order to evaluate the water quality data set, pH, turbidity and free residual chlorine concentration data were collected and each statistical value(mean, variation, range) was calculated, then the seasonal variability of those were analyzed using the independent t-test. From the results of analyzing the distribution of outliers in the measurement data using a high-pass filter, it could be confirmed that a lot of lower outliers appeared due to data missing. In addition, linear filter model based on autoregressive model(AR(1) and AR(2)) was applied for the state estimation of each water quality data set. From the results of analyzing the variability of the autocorrelation coefficient structure according to the change of window size(6hours~48hours), at least the window size longer than 12hours should be necessary for estimating the state of water quality data satisfactorily.