• Title/Summary/Keyword: Water contamination

Search Result 1,532, Processing Time 0.026 seconds

Water Quality Prediction of Chungju Reguration Reservoir by WASP Model (WASP 모형에 의한 충주댐 조정지호의 수질예측)

  • Chang, In-Soo;Park, Ki-Bum;Lee, Won-Ho;Kim, Ji-Hak
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.683-690
    • /
    • 2009
  • The water quality of reservoir can be controled by water quality prediction model because it can not only grasping the present water state but also predicting the water quality in future. In this study, WASP model is used to predict the water quality of Chungju reguration reservoir. This model has some special option which predicts the pollutant outflow phenomenon caused by the contamination sources. So this model is widely used because that can present the scientific basis in this field. This model can help the managers make the right choice of water quality policy. Environmental grade of Chungju reguration reservoir is in III,IV grade which is in bad condition comparatively. The water contamination will be in poor as the year passes. When considering T-N, T-P which are the nutrient to control eutrophication, the concentrated administration about contamination sources is in urgent.

A Study on the Contamination of D.I. Water and its Effect on Semiconductor Device Manufacturing (초순수의 오염과 반도체 제조에 미치는 영향에 대한 연구)

  • Kim, Heung-Sik;Yoo, Hyung-Won;Youn Chul;Kim, Tae-Gak;Choi, Min-Sung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.99-104
    • /
    • 1993
  • We analyzed the D.I. water used in wet cleaning process of semiconductor device manufacturing both at the D.I. water plant and at the wafer cleaning bath to detect the impurity source of D.I. water contamination. This shows that the quantity of impurity is related to the resistivity of D.I. water, and we found that the cleanliness of the wafer surface processed in D.I. water bath was affected by the degree of the ionic impurity contamination. So we evaluated the cleaning effect as different method for Fe ion, having the best adsoptivity on wafer surface. Moreover the temperature effect of the D.I. water is investigated in case of anion in order to remove the chemical residue after wet process. In addition to the control of D.I. water resistivity, chemical analysis of impurity control in D.I. water should be included and a suitable cleaning an drinsing method needs to be investigated for a high yielding semiconductor device.

  • PDF

Usage of Liquid Sugars for Shelf Life Extension of the Cake (케이크의 저장수명 연장을 위한 액체당의 사용)

  • 국승욱
    • The Korean Journal of Food And Nutrition
    • /
    • v.9 no.3
    • /
    • pp.259-264
    • /
    • 1996
  • Five different liquid sugars, invert sugar, corn syrup, high fructose corn syrup, sorbitol and oligosaccharide were compared to improve the shelf life of sponge cake and to decrease the contamination of microorganisms in the baking plant. Sucrose was used as a control. The use of 40% of liquid sugar was more effective than that of 20% on the staling and softness. Invert sugar showed the lowest water activity and the highest water holding capacity. Oligosaccharide showed the highest water activity and the lowest water holding capacity among loquid sugars used. 20% of replacemint of sucrose with invert sugar decreased the contamination more than 100% of sucrose.

  • PDF

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

Comparison of Equipment Contamination Level according to Enteral Nutrition Bag Cleaning and Disinfection Methods (경장영양백 세척 및 소독방법에 따른 오염 정도 비교)

  • Park, Jin-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.4
    • /
    • pp.472-479
    • /
    • 2011
  • Purpose: The purpose of this study was to develop guidelines for cleaning of enteral nutrition bags by comparing the level of equipment contamination according to cleaning and disinfection methods. Method: This study was a true-experimental study, with 60 cases in total. Twenty cases each were randomly assigned to tepid water, detergent and brush, and disinfectant groups. The period of the experiment was March to April 2010, and enteral nutrition was given for 1 houre, 3 times a day at 7AM, noon, and 7PM for seven days. Enteral nutrition bags were cleaned after each feeding according to assigned cleaning and disinfection method followed by microbial cultures on 4th and 8th day before the 7AM feeding. Results: After 3 days of feeding and cleaning, the level of contamination of bags was not significantly different among the three groups. After seven days, the level of contamination was significantly lower when bags were cleaned with detergent and brush or with disinfectant compared to cleaning with tepid water. Conclusion: In cases where enteral nutrition bags are reused for example, in home care settings, studying findings indicate that cleaning bags using detergent and brush or disinfectant is an effective way to prevent contamination of bags.

Monitoring of fecal contamination in a partly restored urban stream in Seoul, Korea

  • Seo, Eun-Young;Jung, Dawoon;Yong, Seung-Cheon;Park, Rho Young;Lee, Young-Ok;Ahn, Tae-Seok
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.211-218
    • /
    • 2016
  • Cheonggye-cheon is a partly restored urban stream located in central Seoul. We monitored fecal contamination using three different fecal indicators, total coliforms (TC), fecal coliforms (FC) and E. coli, to assess differences in each indicator on days of varying weather conditions. Presumptive TC, FC and E. coli colonies were identified by their 16S rRNA sequences. The results showed that enumeration of E. coli provided a better reflection of fecal contamination of the stream than TC and FC. The main sources of contamination were the inflow of fecal-polluted groundwater from the vicinity of a subway line and two inflowing streams. The fecal contamination was worsened on days with heavy rain because untreated sewage from a collecting facility flowed into the stream. Moreover, growth potential of fecal indicator (E. coli) in situ induced by algal exudates was measured. Our results suggest that an appropriate standard based on E. coli rather than TC and FC should be established for improving water quality management strategies of Cheonggye-cheon in the future.

Heavy Metal Contamination in Surface Water Used for Irrigation: Functional Assessment of the Turag River in Bangladesh

  • Arefin, M. Taufique;Rahman, M. Mokhlesur;Wahid-U-Zzaman, M.;Kim, Jang-Eok
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.1
    • /
    • pp.83-90
    • /
    • 2016
  • The aim of the present study was to evaluate the degree of metal contamination of the Turag River water and its suitability for irrigation. Twenty water samples were analyzed for physicochemical parameters and metals viz., calcium, magnesium, potassium (K), sodium, copper (Cu), zinc (Zn), iron (Fe), manganese (Mn), lead (Pb), cadmium (Cd), chromium (Cr), and nickel (Ni). All water samples were slightly alkaline to alkaline. Regarding electrical conductivity (EC), all samples were suitable for crop in soils with moderate permeability and leaching. Water samples were medium salinity and low alkalinity hazard classes. In terms of total dissolved solids (TDS), all samples were classified as freshwater. As per sodium adsorption ratio (SAR) and soluble sodium percentage (SSP), all samples were classified as excellent. No residual sodium carbonate (RSC) was detected in any of the samples, indicating suitability for irrigation; and all samples were considered very hard. Cr and Mn contents in all samples were above FAO guideline values and, therefore, these metals were considered toxic. Zn, Cu, Pb, Cd, and Ni concentrations were below acceptable limit for irrigation and do not pose a threat to soil environment. Significant relationships were found between EC and TDS, SAR and SSP, SAR and RSC, and SSP and RSC. The combinations of ions such as K-Zn, K-Fe, K-Cu, K-Mn, K-Pb, Zn-Fe, Zn-Cu, Zn-Mn, Fe-Mn, Cu-Mn, Cu-Pb and Mn-Pb exhibited significant correlation. This study revealed that Turag River water samples are contaminated with Cr and Mn. This fact should not be ignored because water contamination by metals may pose a threat to human health through food chain.

Modality of Heavy Metal Contamination of Soil in Military Rifle Shooting Range (소화기 사격장의 중금속 오염 양상)

  • Lee, Kwang-Lyeol;Hyun, Jae-Hyuk
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.58-63
    • /
    • 2016
  • The study examined the level of heavy metal contamination by dividing military rifle shooting ranges into the three areas, i.e firing, trajectory, and target. The target area was found to be contaminated at a level higher (Cu 845 mg/kg, Pb 30,487 mg/kg) than the Worrisome Level of Soil Contamination (hereinafter referred to as the “Worrisome Level”) The trajectory area was predicted to be free from contamination, but it did indicate contamination although it was pretty much lower (Cu 23 mg/kg, Pb 99 mg/kg) than Worrisome Level. This is attributed to the contamination spread when rearranging the soil of the target area during the maintenance of the shooting range. The firing area was also predicted to be free from heavy metal contamination, but the results analyzed indicated a contamination higher (Cu 201 mg/kg, Pb 2,286 mg/kg) than Worrisome Level. This is attributed to the fragments of the broken bullet scattering due to the pressure generated as the bullet leaves the muzzle. An examination of heavy metal contamination in the discharge area as well as gutters to prevent the intrusion of rain water from perimeter revealed a high level of contamination (Cu 298 mg/kg, Pb 6,497 mg/kg), which makes it necessary to take measures.

A STUDY ON THE PREDICTION OF GROUNDWATER CONTAMINATION USING GIS (지하수오염 예측을 위한 GIS 활용연구)

  • Jo, SiBeom;Shon, HoWoong
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.2
    • /
    • pp.121-134
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and land-use, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Hwanam 2 District, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice-layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Groundwater contamination potential map was achieved as a final result by comparing modified DRASTIC potential and the amount of pollutant load logically. The result suggest the predictability of contamination potential in a specified area in the respects of hydrogeological aspect and water quality.

  • PDF

Waterborne viruses in drinking water in Korea: survey 1999 for enteric virus contamination in treated water and its source water

  • Rhie KT;Yoon JD;Chung HM;Kim HS;Jeong YS
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.142-142
    • /
    • 2001
  • A national survey for enteric virus contamination in treated water and its source water was performed from March to November 1999. The water samples were subjected to virus filtration at the major water plants producing over 10$^5$ tons treated water per day. Twenty surveyed sites encompass most of heavily populated residential area except for Seoul and Pusan. (omitted)

  • PDF