• 제목/요약/키워드: Water contamination

검색결과 1,534건 처리시간 0.027초

수분오염에 따른 그리스 내 증주제 분해 연구 (Decomposition of Thickener in Grease by Water Contamination)

  • 임영관;함송이;이정민;정충섭
    • Tribology and Lubricants
    • /
    • 제28권1호
    • /
    • pp.33-37
    • /
    • 2012
  • Automotive wheel bearing grease helps to reduce stresses and prevent wear of wheel bearings. But it is easily contaminated by water and other contaminants. Previously, our research group reported the change of grease physical properties such as dropping point, work penetration and oxidation work stability, water washout characteristics, leakage tendency, oil separation, evaporation loss and rust protection by water contamination. In this paper, we analyzed the physical characteristics of grease such as lubricity, viscosity and total acid number to investigate the mechanism of thickener decomposition. In water contaminated grease, the total acid number and wear scar were increased, the viscosity was decreased due to the decomposition of lithium complex thickener.

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

환경오염으로 인한 동굴생태환경의 변화와 환경오염물질 분석에 관한 연구 (A Study on the change of Ecological Environment in Cave cause by the Pollution of Cave Environment and Analysis of Environmental Pollutants in Cave)

  • 이경호
    • 동굴
    • /
    • 제61호
    • /
    • pp.5-16
    • /
    • 2000
  • Recently many environmental researcher are concerned about the ecological environment and the issue of environmental pollution in cave. In this paper we discuss about air pollution, water pollution, state of water quality, ecological environment and situation of environmental public damage in cave The concerning of air pollution in cave is mainly to the type of secondary contamination, which much is developed in various fields recently. The natural water in the most of cave is no problems but ground water has slitting with natural water during much raining period. The state of water quality is gradually contaminated with artificial environmental pollution, that is, the contents of kinds of Aluminum, Nickel, Copper, Zinc and Calcium are higher than before. On the other hand it is very important things to keep the control of constant temperature, darkness and humidity in cave. The contamination by lamp flora and even black colored contamination are appeared nowadays. The ecological environment in cave destructed by growing of mi coorganism. In fact the internal of cave is shielded with the state of climate of cave external but the environment of internal cave is contaminated, because blowing from external climate state. In addition to environmental pollution caused by carbon dioxide and body temperature of tourists. By the way eco-examination of cave is black color public damage, green color one and white color one has been discovered, so we need to have the situation of demand of environmental reservation alternatives.

  • PDF

비음용 지하수 오염물질 기준설정체계 구축 연구: (2) 일반오염물질 (Establishment of Non-drinking Groundwater Quality Standards: General Contamination Substances)

  • 안윤주;남선화;정승우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.24-29
    • /
    • 2014
  • To data, there was no systematic basis for establishing the content and allowed levels of general contamination substances in the Korean groundwater quality standards for non-drinking water. Recently, use of specific procedures for deriving valid groundwater quality standards have become mandatory. This study first investigated the methodology for deriving groundwater quality standards in the European Commission (EC), considering background groundwater quality and domestic and international standards related to water quality. Furthermore, this study investigated the existing specified procedure of standards related to water quality (e.g. surface water, drinking water, and wastewater). Our findings showed that EC and Member States presented the methods for deriving groundwater threshold values for general chemicals. Finally, we have proposed the following procedures of deriving Korean groundwater quality: (1) Selection of groundwater pollutant population, (2) selection and monitoring of priority substances, (3) monitoring, (4) selection of groundwater quality standard candidates, (5) selection of new substances and values for groundwater quality standards.

서울지역 일부 급식학교 편식기 중 합성세제 잔류양 및 미생물 오염도에 관한 연구 (A Study on the Residual Surfactants and the Microbial Contaminants on Stainless dishes)

  • 황순녀
    • 한국식품위생안전성학회지
    • /
    • 제8권4호
    • /
    • pp.241-249
    • /
    • 1993
  • This study was performed to investigate the remainity of synthetic surfactant (LAS) by HPLC and the microbial contamination on stainless steel dishes. For the maintenance and the improvement of school lunch program's safety, the remainity of synthetic surfactants (LAS) on stainless steel dishes washed with auto dishwasher was investigated by HPLC, and the microbial contamination on same dishes was surveyed. The results were as follows: (1) The remainity of synthetic surfactant (LAS) a) The residue of LAS was very small because of the repeated washing of dishes by strong pressurized water. b) The remainity range of LAS on stainless steel dishes was 2.1~7.2 $\mu\textrm{g}$/dish. The remainity of general surfactants was higher in cold water then warm water. The amount of residual general surfatants was 5.95 $\mu\textrm{g}$/dish in cold water, and 2.95 $\mu\textrm{g}$/dish in warm water. There was no difference of the remainity of special surfactants by water temperature. The amount of residual surfactants was 3.9 $\mu\textrm{g}$/dish. c) There was no difference of residue amount by washing times. (2) The microbial contamination after washing with general surfactants. 1) The mean MPN of E. coli was 203(53~345) on 1 hr, 19(6~28) on 2 hrs, in cold water, and 1100(only 1 dish of 1 school) on 1 hr, 24(6~42) on 2hrs. 2) After washing with general surgactants the mean of contamination by general microbials was 956(25~2300)on 1 hr, 694(45~2500) on 2 hrs. in cold water and 803(5~2300) on 1 hr, 671(5~2500)on 2 hrs. After washing with special surfactants the mean of contamination by general microbials was 788(136~2900) on 1 hr, 1122(15~3000) on 2 hrs, in cold water and 537(5~2000) on 1 hr, 88(15~150) on 2 hrs in warm water. (3) Like the results of this study, the good washing methods of stainless steel dishes for school luch program were as follows. First, for washing stainless steel dishes, the use of special surfactants was recommended at 30~4$0^{\circ}C$ water. Second, at 7$0^{\circ}C$ water, the rinsing of dishes was recommended. Third, the final rinsing at 8$0^{\circ}C$ combined with simple disinfection and dry was recommended.

  • PDF

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권2호
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.

전기방식시 적용되는 희생양극의 성능개발에 대한 연구 (A Study on the Sacrificial Anode for Imparting High Capabilities to Cathodic Protection)

  • 김성종
    • 수산해양기술연구
    • /
    • 제34권1호
    • /
    • pp.37-42
    • /
    • 1998
  • Al alloy anode is mostly used for protecting marine structures such as pier steel piles and ship's body. Recently it has been reported that the life of Al alloy anode has been shortened significantly than the original design life. It is suggested that the suspected reasons for this problem mentioned above seems to be the improper protection design of alloy of anode on sea water regardless of environmental facotrs such as flow rate, temperature, contamination degree etc. However there is few paper about to the sea water contamination degree affecting to the life of Al alloy anode. In this study, the property of Al alloy anode was investigated as a parameter of sea water contamination degree such as variation of pH 2, 4, 6, 8, 10 and each sea port's contaminated waters.

  • PDF

토양.지하수오염원 분류체계 구축방안: 2. 분류체계 구축 및 속성자료 활용방안 (Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 2. Construction of Classification System and Applications of Attribute Data)

  • 안정이;신경희;황상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.122-127
    • /
    • 2010
  • Constructing the national inventory that can be used as a tool to identify and assess existing or potential contamination is necessary for efficiently managing the soil and groundwater contamination. In order to start this construction, the first step is how we define and classify potential contamination sources of soil and groundwater. After selecting the basic classification model of contamination sources from developed countries, we suggested the classification and list of the potential contamination sources of soil and groundwater which are appropriate for specific conditions of South Korea. In addition, we investigated several databases to confirm the existence of available data sources and then examined established attribute data through chemical accident response information system (CARIS) and water information system (WIS) in National Institute of Environmental Research and mine geographic information system (MGIS) in Mine Reclamation Corporation. All sorts of attribute data in the existing databases can be utilized as significant assessment factors for determining the management priority of potential contamination sources in the future. Therefore, it is required the expanded investigation of additional database sources and the continual modification so that the classification system of potential contamination sources can be improved.

곶자왈 지역의 의약물질과 농약의 오염수준과 생태독성영향 (Contamination Levels of Pharmaceuticals and Pesticides in the Gotjawal Regions of Jeju Island and Associated Ecotoxicities)

  • 강하병;고수림;최윤송;이상우;고영림;오달영;최경호
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.426-437
    • /
    • 2013
  • Objective: Gotjawal refers to a special geographical designation found in Jeju Province, Korea, where vegetation forms over a rocky area. Due to the important ecological value of Gotjawal, international concern about such areas is growing. However, only limited information is available regarding environmental contamination of Gotjawal. This study was conducted in order to investigate the levels of contamination and associated ecotoxicological effects of surface water bodies in Gotjawal. Methods: Surface water samples were collected at three sampling sites in two Gotjawal areas and were analyzed for several pharmaceuticals and pesticides in consideration of the potential sources of contamination. The ecotoxicity of the samples was measured using water fleas (Daphnia magna and Moina macrocopa) and zebrafish (Danio rerio). In addition, effects on the gene transcription of zebrafish were investigated following exposure to the samples. Results: Nine pharmaceuticals were detected in the samples, but none of the target pesticides were detected. Following acute exposure to two surface water samples, the survival of waterfleas was significantly reduced, but reproduction was not affected. In zebrafish, time-to-hatch was delayed and fry survival was decreased in some samples. On the other hand, at the transcriptional level, there were no genes significantly influenced by exposure to the samples. Conclusion: This is the first study investigating environmental contamination in Gotjawal areas and associated ecotoxicities. Further studies are warranted to identify the cause of acute Daphnia toxicity and to determine potential consequences of longer-term exposure in Gotjawal areas.