• Title/Summary/Keyword: Water condensation

Search Result 477, Processing Time 0.033 seconds

A Study on the Improement of Condensation and Boiling Heat Transfer on Horizontal Tube by Fin Effect(ll)-Shellside Condensation- (수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (2)-튜브외부 응축-)

  • 한규일;조동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1275-1287
    • /
    • 1994
  • Heat transfer performance improvement by fin and grooves is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also tested for comparison. R-11 condenses at saturation state of $32^{\circ}C$ on the outside tube surface cooled by inside water flow. All of test data ate taken at steady state. Beatty and Katz's, Rudy's and Webb's theoretical models are used to predict the R-11 condensation coefficient of tubes having 748, 1024 and 1299 fpm. The predicted value by Betty and Katz's model is within 10% of experimental values in this study at fpm<1024 and Rudy's model predicted the experimental data at fpm>1024 within 15%. The tube having fin density of 1299 fpm and 30 grooves has the best overall heat transfer performance. This tube shows the overall heat transfer coefficient of 11500 $W/m^{2}K$,/TEX> at coolant velocity of 3.0m/s.

Condensation heat transfer of R407C and R410A in a horizontal smooth tube (R407C 및 R410A의 수평원관내 응축열전달)

  • 서정현;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.633-641
    • /
    • 1999
  • Experiments were carried out to investigate the condensation heat transfer characteristics for R22 and its alternatives, R407C (R32/125/134a, 23/25/52wt%) and R410A (R32/125, 50/50wt%). A concentric tube heat exchanger was made to conduct condensation heat transfer tests. Mass flux and saturation temperature of refrigerants at the test section inlet were varied to get the corresponding heat transfer coefficients. Serial and parallel input of secondary fluid (water) were applied to the test subsections. Compared with existing correlations of condensation heat transfer, experimental heat transfer coefficients obtained in this study were generally higher than the predicted values, and mean absolute deviations from several correlations were shown. Wall subcooling was introduced to get a new correlation for condensation heat transfer coefficients by modifying Shah's equation. The RMS deviation of the measured heat transfer coefficients from the new correlation in this study for R22 is 9.9% and that for R407C and R410A are 10.2% and 14.6%, respectively.

  • PDF

Application of the machine learning technique for the development of a condensation heat transfer model for a passive containment cooling system

  • Lee, Dong Hyun;Yoo, Jee Min;Kim, Hui Yung;Hong, Dong Jin;Yun, Byong Jo;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2297-2310
    • /
    • 2022
  • A condensation heat transfer model is essential to accurately predict the performance of the passive containment cooling system (PCCS) during an accident in an advanced light water reactor. However, most of existing models tend to predict condensation heat transfer very well for a specific range of thermal-hydraulic conditions. In this study, a new correlation for condensation heat transfer coefficient (HTC) is presented using machine learning technique. To secure sufficient training data, a large number of pseudo data were produced by using ten existing condensation models. Then, a neural network model was developed, consisting of a fully connected layer and a convolutional neural network (CNN) algorithm, DenseNet. Based on the hold-out cross-validation, the neural network was trained and validated against the pseudo data. Thereafter, it was evaluated using the experimental data, which were not used for training. The machine learning model predicted better results than the existing models. It was also confirmed through a parametric study that the machine learning model presents continuous and physical HTCs for various thermal-hydraulic conditions. By reflecting the effects of individual variables obtained from the parametric analysis, a new correlation was proposed. It yielded better results for almost all experimental conditions than the ten existing models.

A Study of Anti-Condensation on the Surface for Aluminum Butterfly Valves (알루미늄 버터플라이밸브의 표면 결로방지에 관한 연구)

  • Kwak, Kyung-Min;Lee, Joong-Hyoung;Cho, Kyung-Chul;Lee, Eun-Ha
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.73-79
    • /
    • 2021
  • The objective of this study is to prevent or decrease condensation on the surface of aluminum butterfly valves used in high humidity air conditions. We proposed a new valve with an anti-condensation device, a heat resistance medium, instead of a conventional valve. We, then, compared the surface temperature distribution between the proposed and conventional valves using experimental and analytical methods. The size of the evaluated valve is 100A and fluid conditions are 35℃/RH 75% in the air outside the valve and 5℃ in the cooling water inside the valve. The experimental results show that the surface temperature of the proposed valve is 23~42% higher than that of a conventional valve, thereby exhibiting an anti-condensation effect. As a result, we observed the complete prevention of condensation on a gear box mounted to the proposed valve, showing surface temperature distribution above the dew point temperature of air. The analytical results are in agreement with the trends in experimental results.

Bioinspired Metal Surfaces by Plasma Treatment

  • Yu, Ui-Seon;Go, Tae-Jun;O, Gyu-Hwan;Mun, Myeong-Un
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.97-97
    • /
    • 2013
  • The exterior structures of natural organisms have continuously evolved by controlling wettability, such as the Namib Desert beetle, whose back has hydrophilic/hydrophobic contrast for water harvesting by mist condensation in dry desert environments, and some plant leaves that have hierarchical micro/nanostructures to collect or repel liquid water. In this work, we have provided a method for wettability contrast on metals by both nano-flake or needle patterns and tuning of the surface energy. Metals including steel alloys and aluminum were provided with hierarchical micro/nanostructures of metaloxides induced by fluorination and a subsequent catalytic reaction of fluorine ions on metal surfaces in water with various ranges from room to boiling temperature of water. Then, a hydrophobic material was deposited on the structured surfaces, rendering superhydrophobicity. Plasma oxidization induces the formation of superhydrophilic surfaces on selective regions surrounded by superhydrophobic surfaces. We show that wettability contrast surfaces align liquid water within patterned hydrophilic regions during the condensation process. Furthermore, this method could have a greater potential to align other liquids or living cells.

  • PDF

Influence of the Inclination Angle and Liquid Charge Ratio on the Condensation in Closed Two-Phase Thermosyphons with Axial Internal Low-Fins

  • Cho, Dong-Hyun;Han, Kyu-il
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.422-428
    • /
    • 2003
  • This study concerns the performance of the heat transfer of the thermosyphons having 60, 70, 80. 90 axial internal low-fins in which boiling and condensation occurr. Water, HCFC-141b and CFC-11 have been used as the working fluids. The operating temperature, the liquid charge ratio and the inclination angle of thermosyphons have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation, it was found that the maximum heat flow rate in the thermosyphons is dependent upon the liquid charge ratio and inclination angle. A relatively high rate of heat transfer has been achieved by the thermosyphon with axial internal low-fins. The inclination of a thermosyphon has a notable influence on the condensation. In addition, the overall heat transfer coefficients and the characteristics at the operating temperature are obtained for the practical applications.

The regime map for the direct contact condensation of steam vertically injected through a mini nozzle (미세노즐을 통해 수직분사된 수증기의 직접접촉응축 영역도)

  • Lee, Soo-Kwan;Bae, Song-Hyo;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1075-1079
    • /
    • 2004
  • Steam was vertically discharged into water through mini nozzles of various diameters (d=0.115, 0.520, 1.55mm). The condensation was observed and categorized into several types of condensation regimes for each of the nozzles. Compared with the regimes in the previous researches, the regimes of 'internal necking with attached bubble' and 'internal chug with detached bubble' were newly observed. Depending on a nozzle, some regimes expanded, shrank, or moved in the regime map. For the nozzle of 1.55mm, the regime map was similar to Chan and Lee (1982) except that the regime of 'internal chug' was not observed. For the nozzle of 0.115mm, the regime of 'internal chug' appeared even at high pool temperature.

  • PDF

A Study on Performance Test and Fabrication of Vacuum Glazing with Numerical Analysis (수치해석을 통한 진공유리 제작 및 성능실험에 관한 연구)

  • Hwang, Il Sun;Lee, Young Lim
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.303-309
    • /
    • 2013
  • For air-tight modern buildings, secondary damage is likely to occur due to condensation in the relatively high heat-transmission windows since water vapor is not easy to discharge. Therefore, in this study, condensation performance of vacuum glazing was numerically analysed, compared with that of ordinary glass and confirmed experimentally by three sheets of vacuum glazing manufactured. The results show that the heat transmission coefficient of the vacuum glazing whose internal pressure is $10^{-3}$ torr was as low as about $5.7W/m^2{\cdot}K$. Thus, the condensation performance as well as the adiabatic performance was greatly improved compared to that of the ordinary glass.

A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube (알루미늄 다채널 평판관내 R22의 흐름응축 열전달 성능 비교)

  • Seo, Young-Ho;Lim, Dae-Taeg;Park, Ki-Jung;Jung, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1270-1275
    • /
    • 2004
  • Flow condensation heat transfer coefficients(HTCs) of R22 and R134a were measured on horizontal aluminum multi-channel tube. The experimental apparatus was composed of three main parts ; a refrigerant loop, a water loop and a water-ethylene glycol loop. The test section in the refrigerant loop was made of aluminum multi-channel tube of 1.4 mm hydraulic diameter and 0.53 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. The data scan vapor qualities $(0.1{\sim}0.9)$, mass flux ($200{\sim}400$ $kg/m^{2}s$) and heat flux ($7.3{\sim}7.7$ $kW/m^{2}$) at $40{\times}0.2^{\circ}C$ saturation temperature in small hydraulic diameter tube. It was found that some well-known previous correlations were not suitable for multichannel tube. So, It must develop new correlations for multi-channel tubes.

  • PDF

Stereoselective Crossed-Aldol Condensation of Hetarylmethyl Ketones with Aromatic Aldehydes in Water : Synthesis of (2E)-3-Aryl-1-hetarylprop-2-en-1-ones

  • Basaif, Salem A.;Sobahi, Tatiq R.;Khalil, Ali Kh.;Hassan, Mohamed A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.11
    • /
    • pp.1677-1681
    • /
    • 2005
  • Aldol condensation of 2-acetylthiophene, 2-acetylpyrrole and 2-acetylpyridine with different aromatic aldehydes were carried out in water in heterogeneous phases in the presence of cetyltrimethylammonium bromide as cationic surfactant at room temperature. All the reactions occur in a short time with excellent yields of steroselective hetarylpropanones in water as environmental friendly solvent.