• Title/Summary/Keyword: Water and heat degradation

Search Result 66, Processing Time 0.021 seconds

Influence of Acetic Acid Solution on Heat Stability of L-Ascorbic Acid

  • Jang, Keum-Il;Lee, Hyeon-Gyu
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.637-641
    • /
    • 2008
  • This study investigated the heat stability of L-ascorbic acid (AA) in acetic acid solution. To analyze the degradation of AA using high performance liquid chromatography (HPLC), AA was measured at a wavelength of 244 nm in acetic acid and 265 nm in distilled water. During the storage of AA in acetic acid or distilled water at $37^{\circ}C$, degradation of AA was slower in acetic acid than in distilled water. On examining various ratios of AA to acetic acid, the stability of AA at $100^{\circ}C$ for 30 min was the highest when the concentration of acetic acid was 10 times higher than the concentration of AA. After acetic acid was added into AA degraded by heating, the AA is stabilized by reheating. Ultimately, these results indicate that degraded AA is reduced by hydrogen ions dissociated from acetic acid, and the rate of reduction of degraded AA in acetic acid solution is improved with heat processing.

Degradation of Properties and Loss of Nutrients in Gelatin Soft Capsules the Manufacturing Process

  • Lee, Jin Kyoung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.1
    • /
    • pp.15-23
    • /
    • 2016
  • Gelatin soft capsules, manufactured by the press through package(PTP) process, are widely used in the production of multivitamin dietary supplements and other health functional foods. Gelatin capsules can prevent light and air from having a direct contact with the contents in the capsule, and the nutrients inside the capsules are preserved without any loss. In the present study, on the basis of the results on the safety of gelatin capsules. The parameters investigated included degradation of the capsules before their shelf life, capsule deformation, and changes in specific nutrients. Moisture and heat in the production and storage environments of the capsules caused the gelatin to swell and attach some of the inorganic salts in the vitamin contents. Nutritional component analysis showed that B1, B5, B9, and B12 contents were decreased, while mineral elemental analysis shown calcium, chloride, and zinc compound were found to be infused into the gelatin of the capsule shell.

A Study of The Effect of Corrosion on Heat Transfer in a Heat Exchanger (열교환기에서 부식이 열전달에 미치는 영향에 관한 연구)

  • Kwon, Hyun-Min;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.227-232
    • /
    • 2019
  • Heat pump systems based on ocean thermal energy conversion (OTEC) systems use the temperature difference between deep ocean water and surface ocean water to operate. However, they may have heat transfer degradation due to corrosion on the heat exchanger surface due to the salinity of sea water. This study presents experimental results for the heat transfer decrease of corroded metal tubes with respect to corrosion time. In order to replace high-priced titanium, electro-deposition (ED) coating was performed on aluminum tubes. Aluminum tubes with ED coating thicknesses of 10, 15, and $20{\mu}m$ were tested for double-tube heat exchangers after performing accelerated corrosion for 6, 12, and 18 weeks. The effects of the coating thickness and the corrosion time on the heat transfer degradation were investigated. From the results, the aluminum tube with an ED coating of $20{\mu}m$ thickness can be suggested as a candidate for replacing titanium tubes.

A comparison of destructive behaviors of distilled water, salty water, sulfuric acid and heat on glass/vinyl ester composites

  • Asli, S.A.;Shokrieh, M.M.;Kamangar, M.A.
    • Composite Materials and Engineering
    • /
    • v.3 no.3
    • /
    • pp.167-178
    • /
    • 2021
  • In the present paper, the destructive behavior of distilled water, salty water, sulfuric acid, and heat on glass/vinyl ester composites was investigated by experimental methods. Hetron 922 vinyl ester resin and two types of mat and woven glass fibers as the reinforcements were used to fabricate composite test samples. All samples were immersed in distilled water, salty water, and sulfuric acid with three different concentrations. The tests were performed at 20℃ and 70℃ for the exposure duration of 1, 2, 4, and 8 weeks. Bending tests were performed after aging for all composite samples to check the degradation of the bending modulus and strength. The results show that the effect of distilled water, in comparison with salty water, on the degradation of composite samples was significant. On the other hand, almost non-sensitivity of concentrations of salty water on the weight gain of specimens has been observed. In addition, it was also observed that the degradation of samples at 70℃ temperature is much more than that of at 20℃. Also, it was observed that the flexural modulus of virgin specimens exposed to salty water (2% concentration) has been recovered just after two weeks of immersion. Furthermore, in some cases, composite samples under the sulfuric acid solution have lost almost 80% of their mechanical properties.

An Experimental Study on the Defrosting Behavior of a Fin-Tube Heat Exchanger

  • Lee, Kwan-Soo;Jhee, Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.101-111
    • /
    • 1999
  • The effect of various conditions of frosting and defrosting on the defrosting behavior of a fin-tube heat exchanger has been examined experimentally. An electric heater is used for defrosting in a fin-tube heat exchanger. There are several local maxima in the water draining rate. The amount of residual water on the heat exchanger after completion of defrosting is kept constant due to surface tension on the heat exchanger. Without considering degradation of the thermal performance due to the frosting, the defrosting efficiency is improved with increasing amount of frost irrespective of the frosting condition. The defrosting behavior is affected by frosting density as well as frost accumulation, both of which vary with the experimental operating conditions. The heat loss to the surrounding air decreases, and melting and defrosting efficiencies show high values with decreasing heat input.

  • PDF

Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery (연도가스 열회수용 순환유동층 열교환기의 오염저감특성)

  • 이금배;전용두
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage (하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Chang, Ki-Chang;Ra, Ho-sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF

An experimental study of behavior of defrosting on the fin-tube heat exchanger (핀-관 열교환기에 대한 제상 거동에 관한 실험적 연구)

  • Lee, Kwan-Soo;Kim, Kyu-Woo;Ji, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.649-657
    • /
    • 1998
  • In this study, the effects of the various conditions of frosting and defrosting on the behavior of defrosting in a fin-tube heat exchanger have been examined experimentally. The electric heater is used for defrosting in a fin-tube heat exchanger It is shown that there are several local maxima in the water draining rate. The amount of residual water on the heat exchanger after the completion of defrosting is kept constant due to surface tension on the heat exchanger. Without considering the degradation of the thermal performance due to the frosting, the defrosting efficiency is improved with increasing amount of the frost irrespective of the frosting condition. The defrosting behavior is affected by the frosting density as well as the frost accumulation, which vary with the experimental operating conditions during the frosting period. The heat loss to the surrounding air decreases, and the melting and defrosting efficiencies show high values with decreasing heat input.

  • PDF

Characteristics of Drag Reduction Additives in the Application of District Cooling System (지역냉방시스템에의 적용을 위한 마찰저항감소 첨가물 특성 연구)

  • 윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.251-257
    • /
    • 2000
  • District heating and cooling systems offer highly efficient energy utilization and maintenance by centralizing heat management. More pumping power, however, is required because the water has to travel long distance from heat source to the users. In the present study, a trace of drag reduction additives is added to the District Cooling system to achieve a significant drag reduction and save pumping power. Water-soluble polymers, surfactants, and environment-friendly degradable polymers are used as effective drag reducing additives. Time dependent percent drag reductions are compared for various additive solutions at 100 wppm concentration for different water velocity. Without as an anionic surfactant, copolymer was most effective in percent drag reduction. It is found that there exists an optimal condition when copolymer is mixed with SDS. An environment-friendly degradable polymer, xanthan gum, is found to be a significant drag reduction additive. Ice slurry systems, can give less pressure drops compared with chilled water system for certain condtions. Drag reduction additives were also effective for the ice slurry system.

  • PDF

Effects of non-absorbable gases in the absorption process of water vapor Into the Lithium Bromide-water solution film on horizontal tube bank (수평관군에서 리튬브로마이드 수용액 막의 수증기 흡수과정에 대한 비흡수가스의 영향)

  • 김병주;권기석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.218-225
    • /
    • 2000
  • In the present study, the effects of film Reynolds number (60∼200) and volumetric content of non-absorbable gases (0∼10%) in water vapor on the absorption process of aqueous LiBr solution were investigated experimentally. The formation of solution film on the horizontal tubes of six rows were observed to be complete for Re>100. Transition film Reynolds number were found to exist above which the Nusselt number and Schmidt number diminishes with solution flow rate. As the concentration of non-absorbable gases increased, mass transfer rate decreased more seriously than heat transfer rate did. The degradation effects of non-absorbable gases seemed to be significant especially when small amount of non-absorbable gases were introduced to the pure water vapor.

  • PDF