• 제목/요약/키워드: Water absorption rate

검색결과 703건 처리시간 0.021초

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

심지형 저면관수시스템의 심지의 물리적 성질에 따른 수분흡수 특성 (Water Absorption Characteristics of Substrate with Physical Properties of wick in Subirrigation System Using wick)

  • Dong Ho Jung;Jung Eek Son
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 2001년도 봄 학술발표논문집
    • /
    • pp.41-42
    • /
    • 2001
  • The objectives of this study were to investigate the effect of the physical properties of wick on the water absorption of substrate. Physical properties of wick in this study were cotton composition, width and length. The water Infiltration rate through the wick was 0.24 ㎝/s at 90 -95% cotton content, which was faster than at 80-85% (0.13 cm/s) and 70-75% (0.08 cm/s). As the cotton content increased, the water absorption of substrate became greater : the amount of absorbed water was about 5-7g higher at 90-95% than at 80-85% and 70-75% at a wick width of 1 ㎝, the velocity of water absorption through the wick was fastest with 0.25 ㎝ㆍs/sup -1/. The amount of absorbed water was higher at 3 ㎝ than at 1 and 2 ㎝. However, the water absorption rate through the cross - sectional area of wick (g H₂O /㎠/hr) was higher at a wick width of 2 ㎝ than at those of 1 and 3 ㎝. The amount of absorbed water in the substrate was higher at 2 : 1 than at 1 : 1 (length in substrate : length out of substrate). Absorbed water amount was larger at 30-40% initial moisture content than any other treatment.

  • PDF

우사의 수분조절능력 향상을 위한 깔짚소재별 수분흡수속도 평가 (Evaluation of Water Absorption Speed for Litter Materials to Improve the Water Control Ability of Livestock Litter)

  • 노준석;이재훈;이수림;박종환;서동철
    • 한국환경농학회지
    • /
    • 제41권1호
    • /
    • pp.24-31
    • /
    • 2022
  • BACKGROUND: The most common litter materials used in South Korea are sawdust, rice husk, etc. Recently, the cost of litter has been steadily rising, and the maturity test has been strengthened. For this reason, new litter materials are needed for better water control ability to solve the problems. The object of this study was to evaluate the water absorption properties for litter materials. METHODS AND RESULTS: The volumetric water capacity according to the addition of cow manure was investigated to calculate the water absorption speed of litter materials (sawdust, peatmoss, cocopeat, and biochar). The water absorption speed constant (-K) in the first stage was high in the order of cocopeat (0.1190), sawdust (0.0961), biochar (0.0762), and peatmoss (0.0523). The optimal period of the litter use was in the following order: peatmoss (48d), biochar (42d), sawdust (30d), and cocopeat (24d). The water absorption rate (%) of the used litters was high in the order of biochar ≈ cocopeat, sawdust, and peatmoss, which was significantly correlated with the water absorption speed of the first stage. CONCLUSION(S): Considering the water absorption speed and water absorption rate, biochar and peatmoss were found to be the best and optimal litter materials among the tested materials. These litter materials can be used as water control agents in livestock facilities.

프로세스 시뮬레이션에 의한 제 2종 흡수식 열펌프 성능에 관한 연구 (A Study on the Performance of an Absorption Heat Transformer with Process Simulation)

  • 조승연;김영인
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.295-304
    • /
    • 1987
  • The purpose of this study is to develop a computer model for simulating the water-lit hium bromide absorption heat transformer (AHT) Including all major components and to find the flexibility in operation. The effect of source hot water temperature, cooling water temperature, useful hot water flow rate, cooling water flow rate and evaporator circulation flow rate were investigated. The coefficient of performance (COP), temperature boost $({\Delta}T\;=\;T_A\;-\;Ti)$ and concentration variations can be predicted. The performance study indicates that the performance of AHT increases for the waste hot water temperature increasing and with a decrease of the cooling water temperature. The effect on performances of useful hot water flow rape is significant except on temperature boost. Also the effects on performance of cooling water flow rate and evaporator circulation flow rate are small. It is shown that the computer program is valuable to predict the performance of absorp-tion heat transformer units at various working corditions.

  • PDF

Analysis of Leak and Water Absorption Test Results for Water-Cooled Generator Stator Windings

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Wook-Ryun;Lee, Doo-Young;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.230-235
    • /
    • 2012
  • Cases of insulation breakdown damage of water-cooled generator stator windings occur frequently due to coolant leakage and water absorption worldwide. Such serious accidents may cause not only enormous economic loss but also very serious grid accidents in terms of stable supply of electric power. More than 50 % of domestic generators have been operated for more than 15 years, and leak and water absorption problem of windings are often found during the planned preventive maintenance period. Since 2005, leak and water absorption tests have been performed for total watercooled stator windings after fully drying the inside of the windings. The results are then comprehensively analyzed. The result of the test performed by GE, a foreign manufacturer, for 141 generators showed failures in 80 of them (failure rate: 57 %), whereas in the tests carried out in Korean domestic power plants, only 14 out of 50 generators showed failures (failure rate: 28 %).

이성분 나노유체 (NH3/H2O + 나노입자)의 열전달 및 흡수성능 촉진실험 (Experiment on Heat Transfer and Absorption Performance Enhancement for Binary Nanofluids (NH3/H2O + Nano-Particles))

  • 이진기;정청우;강용태
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.669-675
    • /
    • 2008
  • The objectives of this paper are to examine the effect of nano-particles on the pool type absorption heat transfer enhancement and to find the optimal conditions to design a highly effective compact absorber for ammonia/water absorption system. The effect of $Al_2O_3$ nano-particles and carbon nanotube(CNT) on the absorption performance is studied experimentally. The experimental ranges of the key parameters are 20% of ammonia concentration, $0{\sim}0.08\;vol%$ (volume fraction) of CNT particles, and $0{\sim}0.06 \;vol%$ of $Al_2O_3$ nano-particles. For the ammonia/water nanofluids, the heat transfer rate and absorption rate with 0.02 vol% $Al_2O_3$ nano-particles were found to be 29% and 18% higher than those without nano-particles, respectively. It is recommended that the concentration of 0.02 vol% of $Al_2O_3$ nano-particles be the best candidate for ammonia/water absorption performance enhancement.

퇴적암에서 수분값과 화학적 풍화지수(CIA) 간의 상관관계 (Correlation between Water Values and Chemical Index of Alteration (CIA) in Rocks)

  • 박경근;신재열
    • 대한지리학회지
    • /
    • 제50권5호
    • /
    • pp.505-514
    • /
    • 2015
  • 본 연구는 경상북도 구미시 천생산 지역의 조립질 퇴적암을 대상으로 수분값과 풍화지수를 측정하여 상관관계를 분석하고 있다. 암석시료 20개를 대상으로 함수율과 흡수율, 수분측정기를 이용한 계측값 등 다양한 수분값을 구하였으며, 이를 XRF 분석을 통해 얻은 화학적 풍화지수(CIA)와 비교분석함으로써 각각의 상관성을 검토하였다. 분석 결과, 퇴적암의 경우 역의 함유량이 많거나 치밀도가 낮은 암석일수록 함수율과 흡수율은 높게 나타나며 흡수율이 증가할수록 $SiO_2$$Al_2O_3$는 증가하는 경향을 보이는 반면 CaO와 $Na_2O$는 장석류의 풍화로 인해 감소하는 경향이 확인된다. 이는 흡수율이 증가함에 따라 화학적 풍화지수도 함께 증가하는 사실을 보여주는 것으로 화강암을 대상으로 한 기존의 연구들과 유사한 결과를 보여주고 있다.

  • PDF

수평관군에서 리튬브로마이드 수용액 막의 수증기 흡수과정에 대한 비흡수가스의 영향 (Effects of non-absorbable gases in the absorption process of water vapor Into the Lithium Bromide-water solution film on horizontal tube bank)

  • 김병주;권기석
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.218-225
    • /
    • 2000
  • In the present study, the effects of film Reynolds number (60∼200) and volumetric content of non-absorbable gases (0∼10%) in water vapor on the absorption process of aqueous LiBr solution were investigated experimentally. The formation of solution film on the horizontal tubes of six rows were observed to be complete for Re>100. Transition film Reynolds number were found to exist above which the Nusselt number and Schmidt number diminishes with solution flow rate. As the concentration of non-absorbable gases increased, mass transfer rate decreased more seriously than heat transfer rate did. The degradation effects of non-absorbable gases seemed to be significant especially when small amount of non-absorbable gases were introduced to the pure water vapor.

  • PDF

감마선 조사가 검정콩의 수분흡수 특성에 미치는 영향 (Effects of Gamma-Irradiation on the Water Absorption Property of Black Soybeans)

  • 김종군
    • 대한가정학회지
    • /
    • 제30권3호
    • /
    • pp.101-117
    • /
    • 1992
  • Effects of gamma irradiation(2.5∼20kGy) on water absorption property was studied for a local variety of black soybeans. In water absorption patterns of black soybeans, the time to reach a fixed moisture content was reduced depending on the increment of water soaking temperature and irradiation dose. Irradiation at 2.5∼10kGy resulted in the reduction of soaking time of black soybeans by about 1∼3 hours and the increase of hydration capacity by 10∼20%, respectively, compared to the nonirradiated control black soybean. The water uptake rate constant of the irradiated black soybean difinitely increased with the increase of dose levels and water soaking temperature. The activation energy for water absorption and z-value were lower in the irradiated black soybeans than in the nonirradiated control black soybean. The efficacy of water absorption property in the irradiated black soybeans was also recognized after one year of storage at room temperature.

  • PDF

Contact Method에 있어서 Masking Data에 관한 연구 (A Study on the Masking Data in Contact Method for Transparent Copy)

  • 곽선엽
    • 한국인쇄학회지
    • /
    • 제6권1호
    • /
    • pp.67-74
    • /
    • 1988
  • Absorption rates of oxygen in water soluble inks on the printing rollers were measured. As a results of experiments, could be obtained the data of rates of absorption of oxygen in 4 kinds of water soluble inks, and found the difference of absorption rate of oxygen on the parallel plates and rotating rolles.

  • PDF