• 제목/요약/키워드: Water Supply System

검색결과 1,486건 처리시간 0.029초

마닐라 광역시 물공급 이슈(Issues) 진단 (The Assessment of Water Supply Issues in Metro Manila)

  • ;김이형;정상만
    • 한국습지학회지
    • /
    • 제10권3호
    • /
    • pp.37-45
    • /
    • 2008
  • The Philippine government enacted the National Water Crisis Act in 1995, as a response to the burgeoning situation of water supply systems in the country. This act led to the privatization of Metropolitan Waterworks and Sewerage System (MWSS), sector having jurisdiction and control over all waterworks and sewerage systems in a service area including Metro Manila. Nowadays, the region's supply of water is still facing a lot of difficulties, both in quality and quantity. The unabated migration of people to the metro which increases its population, tapping from the aged pipelines, lack of water facilities and infrastructure, excessive groundwater withdrawal, environmental degradation, and surface and groundwater pollution are some of the issues that Metro Manila have to deal with. These situations lead to two primary water supply issues suffered by Metro Manila: water shortage and flooding. The purpose of this paper was to present water supply in Metro Manila with respect to the problems in its distribution, environmental implications and quality. In this paper, several technical reports, published literature, and news articles were consulted and became the major basis for identifying gaps and suggesting remedial measures.

  • PDF

증기발생기 내 냉각수 분사 노즐로의 냉각수 공급 방법에 관한 연구 (Study on the cooling water supply method to the cooling water injection nozzle in the steam generator)

  • 오정화;신민규;조영석;고영성
    • 항공우주시스템공학회지
    • /
    • 제14권5호
    • /
    • pp.66-72
    • /
    • 2020
  • 본 연구에서는 증기발생기 내부로 냉각수 공급 시 화염에 의한 냉각수 분사 노즐 손상이 없도록, 초반 냉각수 공급량을 늘리는 방안에 대한 연구를 진행하였다. 초기 증기발생기 시험 시 벤추리만 사용하여 유량을 제어하였는데, 초반 유량 안정화 구간 동안 연소실 내부로 냉각수 공급이 되지 않아 냉각수 노즐의 손상이 발생하였다. 이를 해결하기 위해 벤추리와 오리피스를 병렬로 구성하여, 초반 공급 유량을 늘림으로써 냉각수 매니폴드와 연소실 사이 차압을 형성시켜 냉각수를 공급하였다. 수류시험을 통해 벤추리와 오리피스 공급 시퀀스를 확립하였으며, 최종 검증을 위해 연소실험을 진행하였다. 실험 결과 연소 초반 지속적으로 냉각수를 공급하는 것을 확인하였으며, 냉각수 노즐 손상 없이 성공적으로 실험을 수행하였다.

SRI 물관리 방법이 논의 관개용수량과 비점오염원 저감에 미치는 영향 (Evaluation of SRI Water Management on the Reduction of Irrigation Supply and NPS Pollution in Paddies)

  • 서지연;박배경;박운지;윤광식;최동호;김용석;류지철;최중대
    • 한국물환경학회지
    • /
    • 제32권2호
    • /
    • pp.183-190
    • /
    • 2016
  • Monitored data (rainfall runoff and water quality) from 4 different paddy sites over 3 years were compared to analyze the effect of irrigation water management on irrigation supply and rainfall runoff quality in Korea. The system of rice intensification water management was adopted at one site (SRI) while the conventional water management method was used for rice culture at the other three sites (CT, SD and HD). The soil texture at SRI, CT and SD was sandy loam while that at HD was silt loam. The average reduction of irrigation supply at SRI compared with CT, SD and HD during the 3 years studied was 49%, 51% and 55%, respectively. The average event mean concentration (EMC) at SRI compared with that at CT, SD and HD was decreased by 35% (BOD), 44% (COD), 47% (SS), 19% (TN) and 38% (TP). The correlation between rainfall runoff and the measured non-point source (NPS) pollutants was very good in general. The comparison revealed that SRI water management significantly reduced both irrigation supply and EMC in rainfall runoff. Paddy NPS pollution was closely related to factors that induce runoff such as rainfall and irrigation supply. It was concluded that SRI management could be an effective and practical option to cope with both water shortage due to climate change and water quality improvement in rural watersheds. However, further studies are recommended in large irrigation districts for use in the development and implementation of NPS pollution policies since the data was collected from field sized paddies.

수돗물의 탄소 배출량 평가 (Carbon Emission Evaluation of Tap Water)

  • 김진근;전홍진
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.511-517
    • /
    • 2011
  • To evaluate carbon emission in water treatment processes, LCA (life cycle assessment) was applied to 8 multi-regional water treatment plants (WTPs) from intake to supply of tap water. Investigation of 8 WTPs revealed that average carbon emission for 1 $m^3$ of tap water was 221 g. Major carbon emission sources in water supply system were intake and supply processes. Meanwhile, mixing process was the main carbon emission source in unit water treatment processes. Carbon emission was proportional to the turbidity and COD of raw water. Intake of better raw water and minimization of energy consumption in unit processes are needed to reduce carbon emission in the WTPs. In addition, comparison of carbon emission among WTPs can be used as a parameter for optimization of operation and maintenance of water treatment processes.

시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 - (Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System -)

  • 이광야;최경숙
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

무선데이터 통신(2.4GHz대)을 이용한 수문 원격제어장치 개발에 관한 연구 (A Study on Development of Remote Control System for Watergate by Used Wireless Transfer Method)

  • 이진구;김일수;박창언
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.237-241
    • /
    • 2003
  • The world's supply of water in all forms is enormous. However, only a tiny fraction of the planet's supply is available to us as fresh water, and that is distributed very unevenly. About 97% of oater volume is found in the oceans and is too salty for drinking, growing crops, and most industrial uses except cooling. In addition water supply crises in already-water-short-regions will intensify because population and industrialization increase. Today, remote monitoring and control systems are becoming the cost-effective management tools for almost all water user groups, including irrigators, water districts, municipal water suppliers, and wildlife management groups. This paper represents a new approach in the water-gate control using radio communication. The proposed device is simple in structure and suitable for implementation of water-gate control through the transceiver by radio communication. It was confirmed that the developed device was very efficient to control level of water-gate and to prove the up and down motion of water-gate through the LCD displayer.

  • PDF

EPANET을 이용한 농업용 관수로 시스템의 운영 및 유지관리 인자 분석 (Analysis of Operating and Maintenance Parameters for Agricultural Pipeline System Using EPANET)

  • 김남도;김선주;권형중;김필식;박현준
    • 한국농공학회논문집
    • /
    • 제59권4호
    • /
    • pp.17-26
    • /
    • 2017
  • In this study, EPANET model which is using on the pipe network analysis was applied to Haenam irrigation district has provided irrigation water by pipeline system about 1,125ha and then have built pipe network to study area and supply performance evaluation of existing structure was analyzed by SPA (Single Period Analysis) in EPANET. As model results of simulation average ratio of maximum supply quantity/irrigation water requirements(base demand) was analyzed by 2.63. It means also that was analyzed as being capable of ensuring the water supply capacity. It was provided the necessary information for the maintenance facility through analyzed hydraulic behaviors in the pipeline inside such as flow velocities, pressures and hydraulic grade lines. It was satisfied with the allowable design criteria that was compared analyzed results with presented allowable design standards at agricultural production infra improvement project planning and design (Pipeline design standard). In order to analyze efficiency promotions of irrigation water, using Extended Period Simulation it was compared supply quantity with irrigation water requirements while pumps set operating pattern in 24 hours, then efficiency promotions of irrigation water was determined through analyzed oversupply water quantity and occurrence time by branch lines. According to results for oversupply quantity in Haenam district by time and end of branch lines efficiency promotions of irrigation water was suggested from 0.33 % to 37.59 %. To draw reasonable operating rules for water use and through this research, it is expected to be helpful for efficient water use and operational management of agricultural pipeline system to the current agricultural irrigation.

국내 정수장의 부식성 특성 연구 (Study on corrosion characteristics of treatment plants in Korea)

  • 민병대;정현미;이이내;최인철;안경희;박주현
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.707-714
    • /
    • 2016
  • In order to prevent secondary pollution of tap water, corrosion characteristics are investigated, and corrosion index are calculated using LI and LR to manage corrosiveness. As targeted water treatment plants from 2014 (July, once) to 2015 (July and October, 2 times), 70 plants are selected by making a division for each area and water system. (treated water samples, n=240, raw water samples, n=72). In result of pH analysis, treated water was lower than raw water to 7.12, and 7.29, respectively. LI were investigated in the order of Seomjin river, Nakdong river, Han river, Geum river, to -2.08, -1.24, -1.11, -1.10 (at raw water), and -2.18, -1.59, -1.51, -1.35 (at treated water), respectively. In case of water quality goal value (LI = -1) in Japan as control of corrosiveness, management object was investigated about 83.3%.

MODSIM을 이용한 농업용 수리시설의 용수공급율 평가 - 금강권역을 중심으로 - (Assessment of the Potential Water Supply Rate of Agricultural Irrigation Facilities Using MODSIM - For Geum River Basin -)

  • 안소라;박근애;신영호;김성준
    • 한국수자원학회논문집
    • /
    • 제42권10호
    • /
    • pp.825-843
    • /
    • 2009
  • 농업가뭄에 대한 대책 마련을 위해서는 가뭄기간 동안의 농업용 수리시설에 의한 용수공급 가능량의 파악이 매우 중요하다. 본 연구에서는 네트워크 물수지 모형인 MODSIM을 이용하여 농업용 수리시설을 고려한 물수지 네트워크를 구성하고 36개년(1967-2002) 동안의 물수지 분석을 수행하여 농업용수 공급측면의 가뭄을 평가하였다. 분석 결과, 과거 가뭄발생 기간에 농업용수 부족량이 다른 기간에 비해 많이 발생함을 확인할 수 있었으며, 대표적인 가뭄 년인 1994, 1995, 2001년의 부족량은 745.8백만 m$^3$, 661.1백만 m$^3$, 696.8백만 m$^3$으로 분석되었다. 또한 소유역 평균 용수공급 가능량은 생 공용수의 경우 99.1 %, 농업용수의 경우 84.4 %로 비교적 낮은 공급 가능율을 보였으며, 1994, 1995, 2001년의 농업용수공급 가능량은 74.8 %, 79.2 %, 77.9 %로 소유역 평균보다 낮은 수준으로 분석되었다. 농업용 수리시설물의 기여도 평가를 수행한 결과 양수장과 보의 기여율은 32.5 %, 집수암거와 관정의 기여율은 4.0 %로 분석되었으며, 집수암거와 관정은 양수장과 보에 비해서 상당히 적은 기여율을 갖지만 농업가뭄 해소에 어느 정도 도움을 주는 것으로 분석되었다.

관개취약성 평가모형 및 군집분석을 활용한 용수공급 위험도 평가 (Water Supply Risk Assessment of Agricultural Reservoirs using Irrigation Vulnerability Model and Cluster Analysis)

  • 남원호;김태곤;홍은미
    • 한국농공학회논문집
    • /
    • 제57권1호
    • /
    • pp.59-67
    • /
    • 2015
  • Because reservoirs that supply irrigation water play an important role in water resource management, it is necessary to evaluate the vulnerability of this particular water supply resource. The purpose of this study is to provide water supply risk maps of agricultural reservoirs in South Korea using irrigation vulnerability model and cluster analysis. To quantify water supply risk, irrigation vulnerability indices are estimated to evaluate the performance of the water supply on the agricultural reservoir system using a probability theory and reliability analysis. First, the irrigation vulnerability probabilities of 1,346 reservoirs managed by Korea Rural Community Corporation (KRC) were analyzed using meteorological data on 54 meteorological stations over the past 30 years (1981-2010). Second, using the K-mean method of non-hierarchical cluster analysis and pre-simulation approach, cluster analysis was applied to classify into three groups for characterizing irrigation vulnerability in reservoirs. The morphology index, watershed area, irrigated area, and ratio between watershed and irrigated area are selected as the clustering analysis parameters. It is suggested that the water supply risk map be utilized as a basis for the establishment of risk management measures, and could provide effective information for a reasonable decision making on drought risk mitigation.