• 제목/요약/키워드: Water Storage Tank

검색결과 389건 처리시간 0.025초

수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험 (Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water)

  • 최인수;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.

축열조 성능에 미치는 디퓨저 형상의 영향 (Effect of Diffuser Shape on the Performance of Water-Chilled Heat Storage)

  • 정재동;박주혁;조성환
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.374-382
    • /
    • 2004
  • Diffuser design is crucial for water-chilled heat storage. Its impact on the system performance is more significant for the underground tank due to inherent limit on the aspect ratio and tank shape. The effect of diffuser shape on the performance of the water-chilled heat storage is numerically investigated. Three dimensional simulation has been conducted for fully incorporating the complex diffuser shape and the non-symmetric tank shape. Mixing at the inlet of the diffuser depends on the inlet Reynolds number, Froude number and the diffuser shape. Three types of the diffuser shape and the broad range of Reynolds number (Re=400, 800, 1200) and Froude number (Fr=0.5, 1.0, 2.0) are examined. The performance of the heat storage tank is evaluated by the thermocline thickness which is reverse to the degree of stratification. The radial regulated plate diffuser, which is the suggested diffuser shape in this study, shows the lowest thermocline thickness in the condition considered.

유전자 알고리즘을 이용한 관수 저류조의 공간배치 최적화 (Optimization of Storage Tank Installation Locations for Pipeline Water Supply Using Genetic Algorithm)

  • 홍록기;박진석;장성주;이혁진;송인홍
    • 한국농공학회논문집
    • /
    • 제64권6호
    • /
    • pp.43-53
    • /
    • 2022
  • Rice paddy has been actively converted into upland crop fields as more profitable upland crop cultivation are encouraged along with the decrease in rice consumption. However, the current water supply system remains mainly for paddy water supply, so research on pipeline water supply for upland cultivation is needed. The objective of this study was to optimize storage tank installation locations for pipeline water supply in reservoir irrigation districts. Five of reservoir irrigation districts were selected as the study sites and gridded of 10×10 m in size. Then genetic algorithm was adopted to evaluate the effects of spatial storage tank allocation on total pipeline cost. The lengths of the main and branch pipelines were considered as the objective cost function for the optimization of storage tank installation. Overall the shorter the branch pipeline and the longer the main pipeline, as the number of storage tanks increase. The minimal pipeline cost, i.e., optimal condition was reached when approximately 10% of the storage tank numbers to total upland plots were installed. The methodology presented in this study can be applied to determine the number and spatial arrangement of storage tanks for upland pipeline irrigation system design.

원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구 (Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank)

  • 조금남;정갑용
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

축열수조의 성능에 관한 실험적 연구 (Experimental Study on the Performance of Heat Storage Tank Using Water)

  • 김시범;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제11권2호
    • /
    • pp.10-15
    • /
    • 1982
  • An experimental study on the storage tank which uses sensible heat of water is done. The influence of inlet flow rate (Re), the difference between initial temperature and inlet water temperature(Gr) and the location of inlet and outlet on the performance of storage tank is studied. Development of stratification is examined by measuring the transient temperatures of 36 points inside the tank. Measured values are transformed to the dimensionless parameters in order to calculate the temperature efficiency of storage tank. In the presence of combined natural and forced convection, the development of stratification becomes clearer and thus the efficiency becomes higher, as $Gr/Re^2$ increases.

  • PDF

합류식하수도 월류수 관리를 위한 초기우수 저류조 설계방안 연구 (A Study on First Flush Storage Tank Design for Combined Sewer Overflows (CSOs) Control)

  • 손봉호;어성욱
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.654-660
    • /
    • 2011
  • One of the best way to control Combined Sewer Overflow (CSO) is proposed to construct first flush storage tank. But there is little known parameters for optimum design of these facilities. This study was conducted to get optimum design parameters for a first flush storage tank construction. The optimization of the tank is generally based upon some measure of SS(Suspended Solid) mass holding efficiency. Water quality deterioration of receiving water body happened right after first time occurring rainfall in dry weather seasons. So, design rainfall intensity is used at 2 mm/hr for peak of monthly average intensities of dry seasons. The capacities for each evaluated catchment are designed from 14.4 min to 16.1 min HRT of CSOs flow at design rainfall intensity. Owing to all storage tanks are connected to interception sewer having a redundancy, the suggested volume could be cut down.

축열시스템의 온수이용 예측에 관한 연구 (The Study on Prediction of Hot Water Extraction in a Thermal Energy Storage System)

  • 조운;박이동
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.71-80
    • /
    • 1998
  • In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load for demand. Lately, practical use of thermal energy storage system and attention to essential use of energy have been increased. From this point of view, especially, a study about the energy extraction process from a storage tank is necessary. So in this study, useful rate of hot water and hot water extraction efficiency was analysed respect to dynamic and geometric parameters dominating the hot water extraction process.

  • PDF

지하저류조 신설에 따른 우수 유출량 저감 (Reduction of Rainfall Runoff by Constructing Underground Storage Tank)

  • 송창근;서일원;정영재
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.927-935
    • /
    • 2013
  • 본 연구에서는 서울대학교 댐 하류 노천강당 유역과 공대폭포 유역에 지속시간 1시간 50년 빈도 강우에 관한 저수지 홍수추적을 실시하고 지하저류조가 설치되는 경우 다음의 사항에 초점을 맞추어 분석을 수행하였다 (1) 저류조의 저류량; (2) 우수유출량 및 첨두수위의 저감정도; (3) 지체시간 변화; (4) 신설 지하저류조의 유출입부 암거 설계. 노천강당 유역에 $25,000m^3$ 저류조가 설치되는 경우 총 유입량 대비 49.43 %의 저류효과가 발생하고 49.64 %의 첨두 유량 감소효과와 28분의 지체시간 증대효과를 얻을 수 있었으며, 첨두 수위는 $15,000m^3$ 저류조에 비해 35 cm 낮게 나타났다. 기존 저류시설과 신설 지하저류조의 공동 운영을 통해, 홍수 발생 시 댐 유역에서 초과되는 유출량을 탄력적으로 관리할 수 있는 것으로 판단된다.