• Title/Summary/Keyword: Water Stage

Search Result 3,067, Processing Time 0.037 seconds

Studies on the Growth Characters and Nutrient Uptake Related to Source and Sink by Cool Water Temperature at Reproductive Growth Stage I. Influence of Cool Water Irrigation on the Degeneration and Differentiation of Rachis Branches and Spikelets, Sterility Ratio and Ripening Ratio of Rice (생식생장기 냉수온이 벼의 Source와 Sink관련형질 및 양분호흡에 미치는 연구 I. 냉수관개가 지경과 영화의 분화 및 퇴화, 불임, 등숙에 미치는 영향)

  • Choi, Su-Il;La, Jong-Seong;So, Jae-Don;Lee, Man-Sang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.4
    • /
    • pp.359-367
    • /
    • 1985
  • This experiment was conducted to study effect of cold water damage on some growth characters related to source and sink at reproductive growth stage in Jinan (sea level 303m). The cold water irrigation duration had irrigated 4, 8 and 12 days at panicle formation stage and reproduction division stage compared to perennial water irrigation. Cold water irrigation shortened culm length and panicle length and degree of panicle exsertion. The shortening effect appeared great at lower internodes when treated at panicle formation stage but at higher internodes when treated at reduction division stage. Cold water irrigation decreased the number of secondary branches and spikelets per panicle, and increased the number of degenerated spikelets being high degeneration when treated at panicle formation stage. Spikelet sterility and impediment of grain filling were affected by duration of cold water irrigation being great when treated at spikelet primodium differentiation stage and reduction division stage in particular. Grain weight was also reduced. Significant relationship existed between spikelets sterility, grain filling and yield. The degeneration of secondary branches and spikelets correlated with leaf area but spikelet sterility and yield with culm length, panicle length and panicle exsertion.

  • PDF

Water Requirement of Maize According to Growth Stage (노지재배 옥수수의 생육시기별 물 요구량 구명)

  • Eom, Ki-Cheol;Park, So-Hyun;Yoo, Sung-Yung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.1
    • /
    • pp.16-22
    • /
    • 2013
  • Water is the most important resource for the maximum water use efficiency and yield of maize. Water has to be applied moderately based on the water requirement of maize. Crop water requirement (WR) is a function of the potential evapo-transpiration (PET) and crop coefficient (Kc). PET can be estimated by the climate data measured at the weather station in the production region. Kc was measured by the NIAST (RDA) through lysimeter experiments. In this study, the growth stage of maize was divided into five ones (G-1: Apr. 25 ~ May 20, G-2: May 21 ~ Jun. 20, G-3: Jun. 21 ~ Jul. 20, G4: Jul. 11 ~ Jul. 25, G5: Jul. 26 ~ Aug. 20). The average PET during maize growing season of the 45 areas was 2.85 mm $day^{-1}$. The highest water requirement was at the G-3 stage among the maize growth stages. The mean water requirement (MWR) according to growth stage was 1.74 ~ 2.42 (average 2.02), 2.99 ~ 4.21 (average 3.41), 3.82 ~ 5.25 (average 4.41), 3.05 ~ 4.31 (average 3.48), and 2.62 ~ 3.49 (average 3.01) mm $day^{-1}$ in the G-1, G-2, G-3, G-4 and G-5 stage, respectively. The total water requirement (TWR) according to growth stage was 45.37 ~ 63.04 (average 52.56), 92.54 ~ 130.59 (average 105.77), 76.46 ~ 105.09 (average 88.14), 45.73 ~ 64.67 (average 52.20), and 68.25 ~ 90.75 (average 78.33) mm in the G-1, G-2, G-3, G-4 and G-5 stage, respectively.

Investigations into a Multipurpose Dam in Tasman District-New Zealand

  • Thomas, Joseph Theodore
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.40-48
    • /
    • 2008
  • The Waimea Basin is located on the northern tip of the South Island of New Zealand. It is a highly productive area with intense water use with multi-stakeholder interest in water. Irrigation from the underground aquifers here makes up the largest portion of used water; however the same aquifers are also the key urban and industrial sources of water. The Waimea/Wairoa Rivers are the main sources of recharge to the underlying aquifers and also feed the costal springs that highly valued by the community and iwi. Due to the location of the main rivers and springs close to the urban centre the water resource system here has high community and aesthetic values. Recent enhanced hydrological modelling work has shown the water resources in this area to be over allocated by 22% for a 1:10 year drought security for maintaining a minimalistic flow of 250 l/s in the lower Waimea River. The current irrigated land area is about 3700 hectares with an additional potential for irrigation of 1500 hectares. Further pressures are also coming on-line with significant population growth in the region. Recent droughts have resulted in significant water use cutbacks and the threat of seawater intrusion in the coastal margins. The Waimea Water Augmentation Committee (WWAC) initiated a three year stage 1 feasibility study in 2004/2005 into the viability of water storage in the upper parts of the catchment for enhancing water availability and its security of supply for consumptive, environmental, community and aesthetic benefits downstream. The project also sought to future proof water supply needs for the Waimea Plains and the surrounding areas for a 50 - 100 year planning horizon. The broad range stage 1 investigation programme has identified the Upper Lee Catchment as being suitable for a storage structure to provide the needs identified and also a possibility for some small scale hydro electricity generation as well. The stage 2 detailed feasibility investigations that are underway now (2007/2008), and to be completed in two years is to provide all details for progressing with the next stage of obtaining necessary permits for construction and commissioning a suitable dam.

  • PDF

An Experimental Study on the Part-Load Performance of a River Water Source 2-Stage Heat Pump (하천수 열원 2단 압축 열펌프시스템의 부분부하 운전특성에 관한 실험적 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1964-1968
    • /
    • 2007
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. Although its better performance, the large temperature difference between load and source makes system performance worse by nature. In this study, 2-stage compression is considered as the solution of this problem. Generally, heat pump is designed for maximum capacity rate, but it actually operates at part load condition in many cases. Therefore, an information on the part-load character is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes. The experimental results show that the system performance is influenced by the part load rates, river water temperature, load temperature, etc.

  • PDF

A study on the part-load performance of 2-stage water source heat pump (2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구)

  • Lee, Young-Soo;Baik, Young-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF

Determination of Stage-discharge Relations by Hydraulic Channel Routing and Stage Measurement (수위관측과 수리학적 하도추적에 의한 수위-유량 관계식작성)

  • Lee, Sang-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.551-560
    • /
    • 2001
  • The research estimated the roughness coefficients for the reach of Hwawon-Goryeonggyo-Hyeongpung stage stations in the Nakdong River through hydraulic channel routing. The data needed were only stage data from the three stations and river cross section data. Stage-discharge relations were determined from the computed discharges by the channel routing. They are better than the previous stage-discharge relations from direct measurements. Discharge computation errors from stage errors were analyzed and a simple method was suggested to limt reach lengths from prohibiting large errors from lateral inflows.

  • PDF

A Study on the Heat Recovery from Boiler Exhaust Gas with Multi-stage Water-fluidized-bed Heat Exchanger (다단 물유동층 열교환기에 의한 보일러 배가스의 폐열 회수 성능에 관한 연구)

  • Kim, Dae-Gi;Park, Sang-Il;Kim, Han-Deok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1776-1783
    • /
    • 2001
  • Heat recovery from boiler exhaust gas with multi-stage water-fluidized-bed heat exchanger is analyzed in this study. The recovered energy here is not only sensible heat but also latent heat contained in the exhaust gas. In this system direct contact heat transfer occurs while exhaust gas passes through water bed and the thermal energy recovered this way is again delivered to the water circulating through heat exchanging pipes within the bed. Thus the thermal energy of exhaust gas can be recovered as a clean hot water. A computer program developed in this study can predict the heat transfer performance of the system. The results of experiments performed in this study agree well with the calculated ones. The heat and mass transfer coefficients can be fecund through these experiments. The performance increases as the number of stage increases. However at large number of stages the increasing rate becomes very low.

Numerical Study of the Performance Characteristics of a Cascade Heat Pump Water Heater at Low Ambient Temperatures (저온 외기조건에서 케스케이드 급탕열펌프의 성능특성에 관한 해석적 연구)

  • Song, Jaehyun;Jung, Haewon;Park, JaeWoo;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.225-232
    • /
    • 2013
  • Heat pump systems have been widely adopted in buildings for cooling and heating, due to their higher energy efficiency. Recently, the demand for hot water supply from the heat pump system has been increasing. To increase the water supply temperature with higher system efficiency and reliability, a heat pump water heater adopting cascade cycle was investigated in this study. The cascade heat pump water heater consisted of a low-stage cycle using R410A, and a high-stage cycle using R134a. A simulation program for the cascade heat pump water heater was developed, and verified by comparison with experimental data. The performance of the cascade heat pump water heater was optimized, by varying the compressor rotating speeds of the low- and high-stage cycles. At low ambient temperatures, the performance of the cascade cycle was compared with that of the single-stage cycle. The system efficiency of the cascade cycle was higher than that of the single-stage cycle, showing a lower compression ratio and compressor discharge temperature.

Optimization of Water Reuse System under Uncertainty (불확실성을 고려한 하수처리수 재이용 관로의 최적화)

  • Chung, Gun-Hui;Kim, Tae-Woong;Lee, Jeong-Ho;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.131-138
    • /
    • 2010
  • Due to the increased water demand and severe drought as an effect of the global warming, the effluent from wastewater treatment plants becomes considered as an alternative water source to supply agricultural, industrial, and public (gardening) water demand. The effluent from the wastewater treatment plant is a sustainable water source because of its good quality and stable amount of water discharge. In this study, the water reuse system was developed to minimize total construction cost to cope with the uncertain water demand in future using two-stage stochastic linear programming with binary variables. The pipes in the water reuse network were constructed in two stages of which in the first stage, the water demands of users are assumed to be known, while the water demands in the second stage have uncertainty in the predicted value. However, the water reuse system has to be designed now when the future water demands are not known precisely. Therefore, the construction of a pipe parallel with the existing one was allowed to meet the increased water demands in the second stage. As a result, the trade-off of construction costs between a pipe with large diameter and two pipes having small diameters was evaluated and the optimal solution was found. Three scenarios for the future water demand were selected and a hypothetical water reuse network considering the uncertainties was optimized. The results provide the information about the economies of scale in the water reuse network and the long range water supply plan.

Simulation on the Optimal Performance and Effective Operating Range of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 이용 2단압축 열펌프의 최적성능 및 효용 운전범위에 관한 시뮬레이션 연구)

  • Jung, Tae-Hun;Park, Cha-Sik;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.295-303
    • /
    • 2008
  • The objectives of this study are to predict actual system performance and effective operating range of the 2-stage compression heat pump system using river water. An electronic expansion valve was applied to the simulation to analyze the effects of operating conditions on the system performance. The developed program was verified by comparing the predictions with the measured data. The results from the present model showed a good agreement with the measured data. In addition, the heat pump simulation was conducted by increasing condenser reservoir inlet temperature to investigate the benefits of the 2-stage compression over the 1-stage compression in the heating mode. The performance of the 2-stage compression cycle was better than that of the 1-stage compression when the inlet temperature of the condenser reservoir was higher than $40^{\circ}C$.