Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

Molecular System Design for the Acetylcholine Fluorescent Chemosensor

  • Kah, Kwang-Nak
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.508-513
    • /
    • 1997
  • We exploited a new molecular system - acetylcholine (neurotransmitter) detection system as a building block for the perfect molecular information system (sensing membrane of the chemical sensor) - using water soluble calix[n]arene-p-sulfonates which are useful even in aqueous (water/methanol) neutral solution. This achievement is due to several outstanding properties of these calix[n]arene derivatives such as low $pK_{a}$ values, cation-interactions, and high water-solubility, etc.

  • PDF

Manufacture and Efficiency Evaluation of Oil Water Separator (유수분리기의 제작과 성능 평가)

  • 유연향;장동환;오무송;이은학;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.160-164
    • /
    • 2000
  • This paper describes oil water separator using difference of electrical resistor. Oil is a non-conductive element and water is a relatively high conductive element. It is possible to detect water included in oil. Electric sensor is formed 8mm iron stick. Valve is operated With controller inputting signal of electric sensor. A experiment was done for necessary voltage in making program of controller. Oil water separator which was tested in field conditions was saved 7% of whole oil and was drained over 150% water than manual valve.

  • PDF

Flower water supply assistant by sensor and Labview (Labview와 센서를 활용한 화초 물 공급 도우미)

  • Park, Sang-Gug
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.849-851
    • /
    • 2010
  • This paper applicate to the large flowers management house, personal office or home, which breed flowers for the profit or hobby. We suggest flower water supply assistant, which supply water anytime to prevent die from water shortage. Our system applicate to the flowerpot less than two at first. We measure humidity by use humidity sensor and control water supply valve automatically. The water supply valve will be opened when the humidity drop to the less than critical values.

  • PDF

Analysis of Water Transport through Measurement of Temperature and Relative Humidity in PEMFC at OCV (개방회로 상태 PEMFC 내부 온도와 습도 측정을 통한 수분투과 분석)

  • KIM, TAEHYEONG;HAN, JAESU;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.353-362
    • /
    • 2022
  • In this study, water diffusion in proton exchange membrane fuel cell at open circuit voltage (OCV) was analyzed through experiment. First, the reliability of the micro-sensor (SHT31) was verified. It was concluded the micro-sensor has an excellent reliability at 60℃ and 70℃. After the sensor reliability test, the temperature and relative humidity measurement in bipolar-plate was conducted at OCV. To analyze water distribution and water flux, the temperature and relative humidity was converted into dew point. To the end, it was found water concentration affects water diffusion.

Design of Optical Biological Sensor for Phycocyanin Parameters Measurement using Fluorescence Technique

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Ann, Myungsuk;Yang, Seungyoun
    • International journal of advanced smart convergence
    • /
    • v.5 no.2
    • /
    • pp.73-79
    • /
    • 2016
  • Remote sensing and measurement are of paramount importance of providing information on the state of water quality in water bodies. The formation and growth of cyanobacteria is of serious concern to in land aquatic life forms and human life. The main cause of water quality deterioration stems from anthropogenic induced eutrophication. The goal of this research to quantify and determine the spatial distribution of cyanobacteria concentration in the water using remote sensing technique. The standard approach to measure water quality based on the direct measurement of the fluorescence of the chlorophyll a in the living algal cells and the same approach used to detect the phycobilin pigments found in blue-green algae (a.k.a. cyanobacteria), phycocyanin and phycoerythrin. This paper propose the emerging sensor design to measure the water quality based on the optical analysis by fluorescence of the phycocyanin pigment. In this research, we developed an method to sense and quantify to derive phycocyanin intensity index for estimating cyanobacteria concentrations. The development of the index was based on the reflectance difference between visible light band 620nm and 665nm. As a result of research this paper presents, an optical biological sensor design information to measure the Phycocyanin parameters in water content.

Wireless Sensor Network Development using RFID for Agricultural Water Management (농업용수관리를 위한 RFID 기반 무선 센서 네트워크 개발)

  • Nam, Won-Ho;Kim, Tae-Gon;Choi, Jin-Yong;Kim, Jin-Taek;La, Min-Chul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.43-51
    • /
    • 2011
  • Irrigation facilities are spread over demand area in a low density and exposed in the field requiring efficient operation and maintenance. Thus, it could be more efficient to manage an irrigation system when it is with wireless sensor network (WSN) using RFID (Radio Frequency Identification) application. A WSN, a kind of ubiquitous sensor network composed of wireless network, RFID and database management system was developed for agricultural water management in terms of operational status and maintenance requirements. Identification code for RFID tag was designed and an application for RFID reader was developed for field data collection, and a database management system was constructed for managing irrigation facility attributes. The system was installed in I-dong irrigation districts in Gyounggi-province, Korea and the operated results showed the applicability of the WSN for agricultural water management.

Basic Study for Cone Penetrometer Type Soil Water Content Sensor using Impedance Spectroscopy (원추 관입형 임피던스 수분센서 개발을 위한 기초 연구)

  • Lee, Dong-Hoon;Lee, Kyou-Seung;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.434-438
    • /
    • 2009
  • This study was conducted to design an cone penetrometer type impedance sensor that can measure soil water content in realtime. The best width between electrical probe was determined by 5 mm. For optimization about realtime application device, linear regression analysis was applied between soil water content and impedance signal. It was concluded that proper combination of excitation frequency, impedance parameter, and model would provide acceptible performance of a soil waler content sensoe. Best model was obatained at a 36.5 MHz with |Z| as a predictor variable, with a coefficient of determination of 0.96 (RMSE=1.35, RPD=4.98).

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

Optical sensing techniques for simultaneous detection of nanoparticles and microorganisms in water (수질내 초미립자와 미생물의 동시 검출을 위한 광학센서기술)

  • Sohn, Ok-Jae;Hyung, Gi-Woo;Kim, Byung-Seb;Rhee, Jong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.157-161
    • /
    • 2008
  • An optical sensor was developed to detect nanoparticles, turbid materials and microorganisms in water simultaneously. Three different light sources like UV-LED, NIR-LED and laser diode have been employed to develop the optical sensor based on the scattering light and fluorescence light. The sensor system has high selectivity and sensitivity, that it can be used to monitor the quality of drinking water.