• Title/Summary/Keyword: Water Screen System

Search Result 89, Processing Time 0.03 seconds

Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront (친수지역 강변여과수 열원을 활용한 냉난방시스템 개발)

  • Cho, Yong;Kim, Dea Geun;Moon, Jong-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.

Liquid-Liquid Dispersion of an Immiscible Liquid Phase (n-Hexane/Water) System in a Stirred Tank (교반조에서 비혼화성 액상(n-헥산/물)계의 액-액분산)

  • Kim, Tae-Ok;Kim, Dong-Uk;Chun, Jong-Han
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.537-543
    • /
    • 1993
  • The effect of agitation on liquid-liquid dispersion was investigated in an immisible liquid phase(n-hexane/water) system. Four different types of six-bladed turbine impellers were used: a flat blade, two screen blades and a solid edged 60 mesh screen blade. We found that the extent of dispersion of organic phase and power consumption of agitator were decreased in the order of flat, solid edged, 60 mesh, and 40 mesh blades at same agitation speed. And the minimum agitation speed for complete dispersion of organic phase was increased with increasing volume fraction of organic phase. Also, mean diameter of liquid droplets of dispersed phase was decreased with increasing agitation speed and it was increased in the order of solid edged, flat, 60 mesh, and 40 mesh screen blades at same agitation speed. At complete dispersion, the minimum power consumption was not vary significantly with impeller blade types, but the solid edged screen blade impeller gave the smallest and uniform sizes of liquid droplets, and it had a good performance for liquid-liquid dispersion. In this condition, Power number was not affected by Reynolds number and it was constant in turbulent flow region, and Sauter mean diameter($d_{32}$) of liquid droplets was expressed as a function of volume fraction of organic phase(${\phi}$) and Weber number($N_{We}$) as follows: $d_{32}/D=a(1+b{\phi})N_{We}{^{-0.6}}$.

  • PDF

Cause Diagnosis and Reduction Measures of Foaming in the Treated Wastewater Outlet of D Wastewater Treatment Plant (하수처리수 방류구의 거품발생 원인진단 및 저감방안: 국내 하수처리장 사례를 중심으로)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • This study was conducted to suggest the cause analysis and mitigation measures of foaming generated in the effluent of wastewater treatment plant. The foam generated in the outlet connected with the tidal river system was identified as structural problems. And the main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. In consideration of these conditions, it present the effective ways such as micro-screen and submerged outlet, to mitigate the foaming generated in the water channel and outlet end.

Application of a Modified Sublimation Method to Screen for PAH-Degrading Microorganisms (다환 방향족 탄화수소(PAH) 분해 미생물 탐색을 위한 승화법의 개발)

  • Kwon, Tae-Hyung;Kim, Jun-Tae;Kim, Jong-Shik
    • Korean Journal of Microbiology
    • /
    • v.46 no.1
    • /
    • pp.109-111
    • /
    • 2010
  • Recent studies have described various microorganisms that can degrade PAH, however, there are currently limited methods available to screen for PAH-degrading microorganisms. To screen for PAH-degrading microorganisms, a sublimation method (Alley, Jeremy F. and Lewis R. Brown. 2000. Appl. Environ. Microbiol. 66, 439-442) was modified to produce a simple screening system. In our results, there were several bacterial species capable of pyrene degradation including genera, Coryenbacterium, Gordonia, Rhodococcus, and Streptomyces, which have been screened from 350 bacterial isolates of commercial gasoline and oil-spilled sediment by the sublimation method. The main advantage of this method is that it (i) safely deposits an even, thin and visible layer of PAH onto the agar surface without the use of solvents and (ii) the quantity of PAH sublimed onto the agar can be easily controlled. Overall, this sublimation method may be an effective and simple technique to screen for PAH-degrading microorganisms.

Application of Heat Balance Model Design of Ventilating and Cooling Greenhouse (온실의 환기 및 냉방 설계를 위한 열평형 모델의 작용)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 2000
  • A certain system to overcome high temperature should be introduced for the stable year-round cultivation in greenhouses. There are efficient methods to overcome high temperature such as ventilation system with shading screen, fan and pad system with screen, and fog system with screen. This study was carried out to find a means to determine the capacity of such system. Heat balance equations for each system were established and verified by experimental results. The calculated ventilation rates from heat balance equations showed a good agreement with the measured ones. The evapotranspiration coefficient was the most important parameter affecting the ventilation requirement among input parameter affecting the ventilation requirement among input parameters except weather data. When the evaportanspiration coefficient increased 1%, the ventilation requirement decreased 1.3%. Therefore the data of evapotranspiration coefficient should be accumulated by various experiments, and then design standards and selection guidelines should be provided. The simulation results for same design conditions shown that air exchanges requirement and evaporating water of fan and pad system were 5.1∼7.7% and 6.8∼9.3% larger than those of fog system, respectively.

  • PDF

Development of Welding Index Table for FD Fan Impeller (임펠러 용접용 인덱스 테이블의 개발)

  • Jeong, Wan-Bo;Kim, Jin-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.570-575
    • /
    • 2010
  • This study is regarding development of an index table for antomation of welding process in impeller fabrication. A PLC, which is widely used for automation in industry, was also adopted as a controller for the index table because of it effectiveness, easy maintenance and repair. The index table consists of centering jig, blade jig, workbench, driving system and a controller. A touch screen was also prepaired as a man-machine interface to provide convenience for workers. Water jacket was installed inside the workbench to reduce thermal stress come from the welding. Temperature of the water jacket was kept constant to cool an impeller main plate effectively. The index table developed in this study convinces that it reduces the total welding time by 50% compared with the conventional process without the table.

The Development Study on the Integrated Management System for Water Information based on ICT (ICT기반의 물정보 통합관리시스템 개발 연구)

  • Hong, Sok-min;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.723-732
    • /
    • 2017
  • As the development of ICT technology, in order to solve the problem of scattered water information's availability, WINS(Water management Information Networking System) by the Ministry of Land, Infrastructure and Transport was established and has been operated since 2004. However, there has been a disadvantage of providing specialized and limited information to the water resources sector mainly and a lack of active sharing of information because of no compulsory provision of information sharing between participants. In order to solve these problems, this paper carried out system development study, to do this, the status of domestic water information was surveyed and domestic and overseas related systems were compared and analyzed. The latest ICT technology was used to realize the contents as screen, and the user interface definition was created to present a role model of integrated water management through maximizing visualization by combining GIS and realtime data and providing space-time integrated information. These prior studies reached to actual construction of the ICT-based integrated management system for water information by K-water. This system is in service to the public installed in the water information portal, "MyWater".

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

The Preparation of NiCuZn Ferrite Slurry Using the Water Mixed Binder System (수계 바인더를 이용한 NiCuZn Ferrite의 슬러리 제조)

  • 류병환;이정민;고재천
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.35-42
    • /
    • 1998
  • Surface mount technology is the biggest theme in the area of deιIronic component. To miniatunze an electronic component, s such as ferrite chip inductor, the cer뼈lic wet process for green-sheet lamination and/or screen printing method through a s solvent medium system is widely used. The preparation and characterization of NiCuZn Ferrite (NCZF) shurry and the green s sheet using the water mixed binder system has been studied. The 21 vol% of NCZF slurry was prepared by a ball milling. The p polyacrylic vinyl copolymer (Mw; 60,000) was used as a binder. Th$\xi$ mixture of distilled water, isopropyl alcohol (IPA) and 2l butoxy ethanol was used as a dispersion medium. The water content of medium varied from about 40% to 80%. As the results. Thc disp$\xi$rston stability of the NCZF slurry was attributed to the free polymer rather than the electrostatic force of the particle. T The viscosity of the NCZF slurry was greatly depended on the ratio of water content in the medium.

  • PDF