• Title/Summary/Keyword: Water Screen System

Search Result 89, Processing Time 0.021 seconds

A Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks (스크린 윅을 삽입한 동-물 히트파이프에서 모세관 한계에 관한 연구)

  • 박기호;이기우;노승용;이석호;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1023-1030
    • /
    • 2002
  • This paper is to research the heat transfer characteristic performance of the copper-water heat pipe with the screen wicks. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size has been much smaller. As a result, a high-performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling water and the mesh number of screen wicks. The distilled water was used for the working fluid. At the inclination angle $6^{\circ}$ in top heat mode, the two layers of the 100-mesh screen wick showed the best heat transfer performance. The thermal resistance of the two layers with the 100-mesh screen was 0.7~$0.8^{\circ}C$/W.

An Experimental Study on Ultrasonic Spray Cooling of Heat Pipe Condenser (히트파이프 응축부의 초음파 분무냉각에 관한 실험적 연구)

  • 김영찬;한양호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.77-83
    • /
    • 2004
  • In this study, the spray cooling heat transfer and working characteristics of the screen wick heat pipe with ultrasonic spray cooling system in condenser were experimentally investigated. The heat pipe was made of copper tube 300 mm long with inner diameter of 11.1 mm. The evaporator and condenser lengths of heat pipe were 40, 200 mm and the wick structure consists of two layer of 100 mesh copper screen. The experimental results show that the ultrasonic spray cooling increases the heat transfer rate on the condenser surface, and the total thermal resistance of heat pipe system decreases remarkably. A comparison is made for the two working fluids, water and ethanol. The surface temperature of the ethanol tube in evaporator section becomes higher than that of the water tube. Thus, the experimental result shows that water is more useful than ethanol as the working fluid because of increasing the operational limit within this experimental conditions.

An Experimental Study on the Heat Transfer Characteristics in Miniature Heat Pipes with Screen Wick (스크린 윅을 삽입한 소형 히트파이프에서 열전달 특성에 관한 실험적 연구)

  • Park, K.H.;Lee, K.W.;Ko, Y.K.;Lee, K.J.;Chun, W.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.572-578
    • /
    • 2001
  • This study is to research the heat transfer characteristics in copper-water heat pipes with screen wick, #100. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size is smaller than before. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle ${-6}^{\circ}$, #100 2layer screen mesh is shown the best heat transfer performance.

  • PDF

An Experimental Study on Heat Transfer Performances in 8mm-diameter Heat Pipes with Screen Mesh Wick (스크린 메쉬 윅을 삽입한 8mm 히트파이프에서 열전달 성능에 관한 실험적 연구)

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Lee, Kye-Jung;Yoo, Seong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.48-53
    • /
    • 2001
  • This experimental study is to research heat transfer characteristics in copper-water heat pipes with screen wick, the 150 and 200-mesh. Recent advances in the miniaturization and large capacity of electronic devices have had a major impact on the design of electronic equipment. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle, number of layer and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle $6^{\circ}$, the 200-mesh screen wick 3-layer is shown the best heat transfer performance.

  • PDF

Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Rhi, Seok-Ho;Yoo, Seong-Yeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • This paper is to study the heat transfer performance of the copper-water heat pipe with screen wicks. Recently, the semiconductor capacity of an electronic unit becomes larger, but its size becomes much smaller. As a result, a high- performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling waters and the mesh number of screen wicks. The distilled water was used as a working fluid. Based on the experimental results, when the copper-water heat pipe of 6mm diameter is used at the top heat mode, the heat transfer performance of 100 mesh 2 layers heat pipe is better than that of 150 and 200 mesh. The thermal resistance of the two layers with the 100-mesh screen was 0.7-$0.8^{\circ}C$/W.

Development of Automatic Backwashing Treatment System for Ballast Water (자동역세척 여과장치를 이용한 선박 밸러스트수 처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.181-185
    • /
    • 2005
  • The treated ballast water from previous treatment contains microorganisms and pathogenic organisms in an filtration treatment system. The advantage of this process can be filtrated to minimize the demage to screen clogging of drum filter with sweeping the solids off rotating the surface of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. Also the fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage, too. Filter rotation speed at 20rpmis 40.5cmHg and 40rpm is 36.6cmHg. Filter out impurities from ballast water over 60rpm is 35cmHg. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the removal of ballast water.

  • PDF

Development of Technology to Secure Refuge Space by Using Existing Restroom (화장실을 이용한 층별 피난공간 확보 기술개발)

  • Kim, Ji-Seok;Shin, Hyun-Joon;Kim, Jung-Yup;Park, Byoung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.24-30
    • /
    • 2015
  • The fire on a high-rise building would possibly cause fatalities because of ineffective egress due to extended evacuation distance in huge building structure, coupled with dense population, thus requiring secured optimal evacuation method and space. The restroom located in the living space is considered to be useful refuge space which is built with wet pipe and noncombustible materials. This study aimed to develop a system that would make use of the existing restroom as a fire refuge space. Ventilation duct were installed to discharge odor during normal conditions. We could serve the air supply duct to also raise the air pressure in the restroom so as to prevent the toxic gas from gapping around the restroom. The nozzle for the water screen would be installed in restroom door facing the living room to form the water screen which would protect the door. This study is intended to replace the existing refuge space with the restroom in such a way as described above.

A Study on the Cooling Block Design for a Large Touch Screen Panel (TSP) Cover Glass Molding System (대형 Touch Screen Panel(TSP) 덮개유리 성형기의 냉각 블록 설계에 관한 연구)

  • Lee, Jun Kyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.6
    • /
    • pp.36-42
    • /
    • 2020
  • Nowadays, the touch screen panel (TSP) cover glass for mobile smart devices is being developed with a curved glass shape due to different design requirements. Because the sizes of mobile smart devices continue to increase, there has also been a great increase in the demand for large-area curved glass greater than 20 inches. In this study, heat and fluid flow analysis using CFD was performed to optimize the heating surface temperature distribution of the large curved glass formation system. Five cooling water flow paths in the cooling block were designed and analyzed for each case. A function that can quantitatively calculate the temperature uniformity of the heating surface was proposed and these values were obtained for the five models. The temperature distributions of the heating surface and the energy consumption of the heating system were also compared and comprehensively analyzed. Based on the analysis results of the five different cooling channel path models, the optimal path design could be presented.

A study of Ballast water Treatment using a Disk filter (디스크 여과장치를 이용한 선박 밸러스트수 전처리 연구)

  • Park, Sang-Ho;Lim, Jae-Dong;Park, Sun-Jung;Kim, Dong-Geun;Kim, In-Soo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.149-150
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic back washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop oft the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 2.6bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

음성인식 기반 인터렉티브 미디어아트의 연구 - 소리-시각 인터렉티브 설치미술 "Water Music" 을 중심으로-

  • Lee, Myung-Hak;Jiang, Cheng-Ri;Kim, Bong-Hwa;Kim, Kyu-Jung
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.354-359
    • /
    • 2008
  • This Audio-Visual Interactive Installation is composed of a video projection of a video Projection and digital Interface technology combining with the viewer's voice recognition. The Viewer can interact with the computer generated moving images growing on the screen by blowing his/her breathing or making sound. This symbiotic audio and visual installation environment allows the viewers to experience an illusionistic spacephysically as well as psychologically. The main programming technologies used to generate moving water waves which can interact with the viewer in this installation are visual C++ and DirectX SDK For making water waves, full-3D rendering technology and particle system were used.

  • PDF