• Title/Summary/Keyword: Water Risk

Search Result 1,720, Processing Time 0.029 seconds

Development and Evaluation of the KOrea Insecticide Exposure Model (KOIEM) for Managing Insecticides

  • Jung, Ja-Eun;Lee, Yong-Ju;Kim, Yoon-Kwan;Lee, Sung-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.1183-1189
    • /
    • 2012
  • The KOrea Insecticide Exposure Model (KOIEM) was developed to facilitate ecological risk-based management of Korean insecticides. KOIEM, applied as a multimedia fate model, evaluates water, soil, air, and vegetation compartments based on three water-body types (streams, ditches, and ponds). Deltamethrin, a pyrethroid insecticide, was used to evaluate and create the model parameters. After exposure of both the stream and the ditch to deltamethrin, the KOIEM-predicted concentrations and the observed levels were in agreement. The model was also evaluated using the accuracy factor (AF), which was 4.32 and 0.35 for the stream and ditch, respectively. Ecological risk assessment was also performed to evaluate the application of KOIEM for four popular South Korean insecticides (cypermethrin, deltamethrin, diazinon, and permethrin). Despite the insecticides having low PECs in water, their risk quotients were typically above 1.0. Thus, KOIEM modification would be required in further studies to account for spatial variation.

The role of domestic tap water in Acanthamoeba contamination in contact lens storage cases in Korea

  • JEONG Hae Jin;YU Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.2 s.134
    • /
    • pp.47-50
    • /
    • 2005
  • A survey was carried out from August to December 2004 in Pusan, Korea to document the presence of free-living amoeba (FLA), including the genus Acanthamoeba, in both contact lens storage cases and domestic tap water. Acanthamoeba was isolated from $5(4.2\%)$ in 120 contact lens storage cases. Four house tap water samples from residents, whose contact lens storage cases had been contaminated by Acanthamoeba, were also found to be contaminated with Acanthamoeba. Therefore, the contamination rate of FLA and Acanthamoeba in domestic tap water was investigated in order to examine the role of domestic tap water in Acanthamoeba contamination of contact lens storage cases. FLA and Acanthamoeba were identified in $97(46.8\%)\;and\;16(7.7\%)$ of the 207 domestic tap water samples, respectively. There were no significant differences between the contamination rates of FLA in tap water according to the filtration plant of origin. No FLA was detected in the tap water directly supplied by the water purification plants. Water storage tanks appear to promote FLA colonization, including Acanthamoeba, in domestic tap water. This increases the risk of Acanthamoeba contamination in contact lens storage cases as well as increasing the risk of Acanthamoeba keratitis.

A study on adaptation measures to climate crisis for water supply system of Jeju Special Self-Governing Province (제주특별자치도 상수도 기후위기 적응대책 연구)

  • Jinkeun Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.447-456
    • /
    • 2023
  • Risk assessment on Jeju Special Self-Governing Province(JSSGP)'s water supply facilities and establishment of adaptation measures for climate crisis factors were implemented. JSSGP's vulnerability to the climate crisis was high in the order of drought, heat wave, heavy rain and strong wind. As a drought adaptation measure, policies of water saving and revenue water ratio improvement were considered. As for the heat wave adaptation measure, the introduction of an advanced water treatment process was suggested in response to the increase of algae cell number which resulting in taste and odor problem. As for heavy rain adaptation measures, the installation and operation of automatic coagulant injection devices for water purification plants that take turbid surface water were proposed. As a measure to adapt to strong winds, stabilization of power supply such as installation of dual power line was proposed in preparation for power outages. It is expected that water facilities will be able to supply high-quality tap water to customers even under extreme climate conditions without interruption through risk assessment for climate crisis factors and active implementation of adaptation measures.