• Title/Summary/Keyword: Water Resources Plan

Search Result 547, Processing Time 0.026 seconds

Influences of Fish Farm on the Physicochemistry of Stream Water Quality in Mt. Baegun Area(III) (백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장의 영향(III))

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.4
    • /
    • pp.46-55
    • /
    • 2001
  • Analysis of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around Mt. Baegun area were monitored seasonally for three years. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. As a result of regression analyses, the linear equation of pH of influent and effluent water of fish farm was, pH of effluent water of fish farm = $0.6234{\times}pH$ of influent water of fish farm + 2.6263. Also, the linear equation of electrical conductivity of influent and effluent water of fish farm was electrical conductivity of effluent water of fish farm = $1.7275{\times}$electrical conductivity of influent water of fish farm - 14.007. Negative effects on stream water quality were observed by indications of increase in electrical conductivity and water temperature of effluent water from the fish farm. Decreases in physicochemical indices such as the amount of dissolved oxygen, total amount of cation and total amount of anion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as environmentally-friendly fish farm design should be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF

Assessment of Flood Flow Conveyance for Urban Stream Using XP-SWMM (XP-SWMM을 이용한 도시하천에서의 홍수소통능력 평가)

  • Hong, Jun-Bum;Kim, Byung-Sik;Seoh, Byung-Ha;Kim, Hung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.2 s.163
    • /
    • pp.139-150
    • /
    • 2006
  • In recent, increasing of the impervious area gives rise to short concentration time and high peak discharge comparing with natural watershed and it is a cause of urban flood damage. Therefore, we have performed for structural and non-structural plans to reduce the damage from inundation. The Gulpo-cheon basin had been frequently inundated and damaged due to the water level of Han river. So, the Gulpo-cheon floodway was constructed with 20 meters width for flood control in the basin but it was not enough for our expectation and now we have a plan to expand the floodway to 80 meters. We use a XP-SWMM model developed based on EPA-SWMM version for analyzing the capacity of flood conveyance by the expansion of Gulpo-cheon floodway with the same 100 years return period design storm and the same tidal conditions of the Yellow sea. The flood conveyance after the expansion of floodway becomes three times comparing it with before the expansion. Also we simulate the flood discharge at the diversion point of Gulpo-cheon for the expanded condition of floodway and know that the discharge of about 300 m3/sec is flowing backward to the expanded floodway. Therefore we may need some kinds of hydraulic structures to prevent the back water.

Optimization of Water Reuse System under Uncertainty (불확실성을 고려한 하수처리수 재이용 관로의 최적화)

  • Chung, Gun-Hui;Kim, Tae-Woong;Lee, Jeong-Ho;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.131-138
    • /
    • 2010
  • Due to the increased water demand and severe drought as an effect of the global warming, the effluent from wastewater treatment plants becomes considered as an alternative water source to supply agricultural, industrial, and public (gardening) water demand. The effluent from the wastewater treatment plant is a sustainable water source because of its good quality and stable amount of water discharge. In this study, the water reuse system was developed to minimize total construction cost to cope with the uncertain water demand in future using two-stage stochastic linear programming with binary variables. The pipes in the water reuse network were constructed in two stages of which in the first stage, the water demands of users are assumed to be known, while the water demands in the second stage have uncertainty in the predicted value. However, the water reuse system has to be designed now when the future water demands are not known precisely. Therefore, the construction of a pipe parallel with the existing one was allowed to meet the increased water demands in the second stage. As a result, the trade-off of construction costs between a pipe with large diameter and two pipes having small diameters was evaluated and the optimal solution was found. Three scenarios for the future water demand were selected and a hypothetical water reuse network considering the uncertainties was optimized. The results provide the information about the economies of scale in the water reuse network and the long range water supply plan.

Development of Climate Change Adaptation Plan for Kurunegala City, Sri Lanka (스리랑카 Kurunegala시의 기후변화 적응 계획 개발)

  • Reyes, Nash Jett DG.;Cho, Hanna;Geronimo, Franz Kevin F.;Jeon, Minsu;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.354-364
    • /
    • 2019
  • Sri Lanka is an island nation susceptible to climate-related disasters and extreme weather events. Kurunegala City is the developing capital city of the North-Western Province of Sri Lanka. Changes in rainfall patterns and a steadily increasing annual average temperature amounting to 0.69±0.37℃ were observed in the city area. Generally, urban areas are at risk due to the lack of climate change adaptation provisions incorporated in the development plans. This study was conducted to investigate the characteristics of Krunegala City, Sri Lanka and develop an appropriate climate change adaptation plan for the city. Site investigation and qualitative risk assessment were conducted to devise a plan relevant to the climate change adaptation needs of the city. Qualitative risk analyses revealed that drinking water, water resources, and health and infrastructure risks were among the major concerns in Kurunegala City. Low impact development (LID) technologies were found to be applicable to induce non-point source pollutant reduction, relieve urban heat island phenomenon, and promote sound water circulation systems. These technologies can be effective means of alleviating water shortage and reducing urban temperature. The measures and strategies presented in this study can serve as reference for developing climate change adaptation plans in areas experiencing similar adverse effects of climate change.

A Study on Application and Verification of Heavy Water Treatment Effects Using Plant Cultivation (Vegetation) on Floating Island (식생섬에 의한 중수처리 효과 검증과 적용에 관한 연구)

  • Kwon, Dong Min;Kwon, Soon Hyo;Koo, Bon Hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This this study was conducted with the aim of doing experiment on the effect of water purification by using an artificially built plant island, which is one of the eco-techniques, and aquatic plants as a plan for the reuse of water for obtaining water resources, thereby analyzing the removed quantity, and applying the experimental results to the reuse of water. As a result of doing experiments, this study obtained a good measured value of BOD (biochemical oxygen demand) 4.7mg/L, and COD (chemical oxygen demand) 7.2mg/L below the heavy water standard of BOD 10mg/L and COD 20mg/L, respectively. The chromaticity showed 89.2% removal efficiency, but final treated wastewater was found to show chromaticity 58 degrees exceeding chromaticity 20 degrees which are the water quality standard of the reuse of water. The results revealed that T-N produced 27% removal efficiency on an average while T-P produced 38% removal efficiency on an average, showing that the removal effect of N & P wasn't big. According to the currently enforced "Water Quality Standard of Heavy Water by Use", the use of water for sprinkling and landscaping was found to be available. Accordingly, this study suggested a nature-friendly, economically-efficient, and eco-technological water treatment technique which will make it possible to overcome the limit of the existing physio-chemical water treatment technology, reduce the costs for maintenance and facilities, and also reduce the limit of space restraint for installation of facilities.

Analysis of the Water Quality Change Due to Water Level Control of Sayeon Dam (사연댐 수위조절시 수질변화 분석)

  • Lee, Sang Hyeon;Cho, Hong Je
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1069-1078
    • /
    • 2013
  • The Bangudae Petroglyphs, national treasure No. 285 is located within submerged upper districts of Sayeon dam supplying the main residential water in Ulsan. Of the many ways for the reservation of Petroglyphs located the altitude at 53~57 m, the plan that we take it out of the water lowering the water level from 60 m to 52 m has been examined mainly in case of controlling artificially the water level of the dam. In this paper, we examined expected problems from the loss of dam function and the change of water quality from water deterioration caused by the water level control of the Sayeon dam. Using the model of Vollenweider and CSTR (Continuous Stirred Tank Reactor), we analyzed the density change of BOD and COD, representative water quality index and the TP and TN, the main reason of algae growth. The result showed that the density of COD lowered a little but the density of TP and TN went up over 130% when controlling the water level from 60 m to 52 m. These changes cause a serious algae problem and if doing the water quality management as the density of TN and TP, the water quality would become worse. Water storage and supply residential water decreases, and the water quality becomes worse because of eutrophic state.

Velocity-based decision of water quality measurement locations for the identification of water quality problems in water supply systems (상수도시스템 수질사고 인지를 위한 유속기반 수질계측기 위치 결정)

  • Hong, Sungjin;Lee, Chanwook;Park, Jiseung;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.1015-1024
    • /
    • 2020
  • Recently, water pollution accidents have continued to occur in pipelines such as red water Incheon and Seoul. In order to recognize this water quality problem, it is necessary to install a water quality sensor in an appropriate location and measure it in advance to detect or block the water supply to the water faucet of the shelter. However, there are limitations, such as maintenance costs, to installing multiple water meters in all pipelines. Therefore, this study proposed a methodology for determining and prioritizing the installation location of flow-based water quality sensor for the recognition of water quality problems in pipelines. We applied the proposed procedure to the pipe break scenario. The results of the determination of the location of the water quality sensor were presented by applying it to the pipe network that actually operates the emergency pipe in Korea. The result of the decision showed that in the event of abnormal situation caused by the destruction of individual pipes, the flow rate of the pipes around the aqueduct and the tank may change rapidly, resulting in water quality accidents caused by turbidity. In the future, it is expected that the water quality monitoring point selection method, such as establishing an external pipe operation plan for pipe cleaning, will utilize the procedure for determining the location of the water quality sensor according to the velocity.

Impacts of sea-level rise on port facilities

  • Son, Chang-Bae;Kim, Chang-Je;Jang, Won-Yil;Matsubara, Yuhei;Noda, Hedeaki;Kim, Mi-Kum
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.173-177
    • /
    • 2006
  • From the viewpoint of coastal hydrodynamics, one of the most important effects of global warming is a sea-level rise in coastal areas. In the present study, impacts on port facilities against sea-level rise were investigated. The sea-level rise causes the increase of the water depth, and it generates variations on the wave height, buoyancy, tidal system and nearshore current system and so on. The increase of water depth gives rise to the decrease of crown height of the structure and it causes increase of wave overtopping quantity. It may flood the port zone and its facilities, and may decrease harbor tranquility. It also leads to difficulties on navigation, mooring and loading/unloading at the port. Increase in water depth also causes increase of wave height in surf zone. This high wave makes structures unstable and may cause them to collapse during storm. In addition, increase in buoyant force due to sea-level rise also makes the gravity type structures unstable. Consequently, theses variations due to sea-level rise will cause functional deterioration of port facilities. In order to protect port facilities from the functional deterioration, reinforcement plan is required such as raising the crown height and increase in block weight and so on. Hence proper estimation method for the protection cost is necessary in order to protect port facilities efficiently. Moreover response strategies and integrated coastal zone management plan is required to maintain the function of port facilities. A simple estimation of cost for breakwaters in Korea was performed in the present study.

  • PDF

Risk Model for the Safety Evaluation of Dam and Levee: II. Application (댐 및 하천제방에 대한 위험도 해석기법의 개발 : II. 적용 예)

  • Han, Geon-Yeon;Lee, Jong-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.691-698
    • /
    • 1997
  • The risk assessment model for dam and levee is applied to a river where two adjacent dams are located in the upstream of the watershed. "A" dam is proven to be safe with 200-year precipitation and unsafe with PMP condition, whereas "B" dam to be safe with 200-year precipitation and PMP condition. The computed risk considering the uncertainties of the runoff coefficient. initial water depth and relevant data of the dam and spillway turn out to be equivalent results in Monte-Carlo and AFOSM method. In levee risk model, this study addresses the uncertainty of water surface elevation by Manning's equation. Monte-Carlo simulation with the variations of Manning's roughness coefficient is calculated by assuming that it follows atriangular distribution. The model can be used for preparing flood risk maps, flood warning systems, and establishing nation's flood disaster protection plan.

  • PDF

Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant (하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.52-59
    • /
    • 2012
  • As the result of reviewing the linked treatment of water quality for treating process at public livestock wastewater treatment facilities for fair selection of the proper linked process in case of linking sewage treatment plant for livestock wastewater, in case of wastewater processed by bio-reactor that is only biologically-treated, the load factor showed relatively high as 1.67%(base on design quality), 2.59%(base on operation quality) regarding COD and 3.69%(base on design quality), 7.67%(base on operation quality) regarding $COD_{Mn}$ but it is judged that there is nearly no influence on the operation of sewage treatment plan. And, in case of oxidized flotation-treated water & biofiltlation-treated water that are the advanced wastewater treatment, the load factor is approximately 1% and there is concern about the installation of excessive facilities in case of installing the advanced wastewater treatment. So, in case of considering the economic efficiency & stable operation of sewage treatment plant S, it is judged to be desirable to link with wastewater processed by bio-reactor that is biologically-treated.