• Title/Summary/Keyword: Water Region

Search Result 3,268, Processing Time 0.033 seconds

Ultrastructure of the Ampullate Glands in the Orb Web Spider, Nephila clav ata L. Koch III. Excretory Duct of the Small Ampullate Gland (무당거미(Nephila clavata L. Koch) 병상선(甁狀腺)의 미세구조(微細構造) III. 소병상선(小甁狀腺)의 분필관(分泌管))

  • Moon, Myung-Jin;Kim, Woo-Kap
    • Applied Microscopy
    • /
    • v.19 no.1
    • /
    • pp.49-58
    • /
    • 1989
  • Ultrastructure of the excretory duct of the small ampullate gland in the orb web spider, Nephila clavata L. Koch are studied with light and electron microscopes. The small ampullate glands, located near the midline portion of the abdominal cavity, are connected with the spigots(large spinning tubes) on the middle spinnerets and composed of three parts which are the excretory duct, the storage sac and the convoluted tail. The excretory duct of this gland is enclosed by a thin layer of the outer connective tissues. By the morphology of the apical cuticles and internal textures of the epithelial cells, the duct is subdivided into two regions which are proximal duct region near the sac and distal duct region near the spinnerets. At the distal region of the ducts, the subcuticle which had the function of water removal form the progenetive silk material is well developed, whereas at the proximal region this cuticle disappeared and instead of these, endocuticle is developed. Moreover the epithelium of the distal duct region is composed of columnar epithelial cells, but at the proximal region the epithelium is changed to squamous or cuboidal forms. In the cytoplasm of the epithelial cells, rough endoplasmic reticula, Golgi comlexes and large secretory vesicles related to the production of the cuticular materials are well developed. And between the adjacent epithelial cells, specialized septate junction and desmosomes are formed along the plasma membrane.

  • PDF

Natural Environment and Agriculture in Chuncheon Region during the Bronze Age (청동기시대 춘천지방의 자연환경과 농경)

  • Lee, Eui-Han
    • Journal of the Korean association of regional geographers
    • /
    • v.9 no.4
    • /
    • pp.493-504
    • /
    • 2003
  • The remains of the Bronze Age in Chuncheon region are mostly distributed on the floodplain. The floodplain in this region is made up mainly of natural levee that is high in height and is not flooded with water. The natural levee has very advantageous conditions in agriculture compared with other places. There is a high possibility that people in Chuncheon region during the Bronze Age inhabited on the floodplain and engaged in agriculture. Considering the geomorphic features and soil of natural levee, it is believed that the agriculture centered on dry-field farming was done in this region at that time.

  • PDF

A Relationship between the Sea Level Variations in the Korea Strait and the Tokara Strait in the Kuroshio region

  • Hong Chul-Hoon
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.1
    • /
    • pp.113-121
    • /
    • 1998
  • A relationship between sea level variations in the Korea Strait (the western and the eastern channels) and the Tokara Strait in the Kuroshio region is examined using daily-mean sea level data from 1966 to 1986. The seasonal variation of the sea level difference (SLD) between Izuhara and Pusan (the western channel) is most periodic: the positive anomalies appear from summer to autumn, and the negative anomalies from winter to spring year to year, whereas SLDs neither between Hakata and Izuhara (the eastern channel) nor between Naze and Nishinoomote (the Tokara Strait) show such a periodic variation. Much similarity has been found between SLDs in the eastern channel and the Tokara Strait, and in particular they were closely correlated in a special event of the Kuroshio region, such as a large meander of the Kuroshio. This paper shows that the periodic seasonal variation of the SLDs in the western channel should be less related to the Kuroshio region. This result also implies that the variation of SLD in the western channel is largely influenced by local factors, such as the bottom cold water in the western channel in summer, rather than from the Kuroshio region.

  • PDF

Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region (희박 분무영역에서의 분무냉각 막 비등 열전달에 관한 연구)

  • Kim Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.279-286
    • /
    • 2005
  • This study presents experimental results on the heat transfer coefficients in the film boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distributions of a two dimensional dilute spray impinging on a hot plate were experimentally investigated. A stainless steel block was cooled down from intial temperature of about $800^{\circ}C$ by twin fluid (air-water) flat spray. It was found from the experimental results that the heat transfer area was classified into the stagnation region and wall-flow region. In the stagnation region, the experimental data of local heat transfer coefficient was closely correlated with the local droplet-flow-rate supplied from the spray nozzle directly. Thus, the local heat transfer coefficients are in good agreement with the predicted values from the correlations proposed by our previous study. In wall-flow region, however, remarkable differences are observed between experimental data and predicted values because the number of rebound droplets increase with increasing the distance from the stagnation point.

Seasonal Variation of Phytoplankton in the East Sea Using A Surface Mixed Layer Ecosystem Model (표층혼합층 생태계모델을 이용한 동해 식물플랑크톤의 계절변화)

  • KIM Sang Woo;ISODA Yutaka;AZUMAYA Tomonori
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.2
    • /
    • pp.178-186
    • /
    • 2003
  • Seasonal variation of phytoplankton was investigated with surface mixed layer ecosystem model in the East Sea. The model consisted of four compartments (phytoplankton, zooplankton, nutrient, detritus) forced by mixed layer depths, photosynthetically available radiation and nutrient concentrations. From model results we estimated entrainment rate $2.5-4.0\;m{\cdot}day^{-1}$ to reproduce the two annual blooms, and reproduced seasonal variation of phytoplankton at southern and northern regions by the difference of surface winter mixed layer depth (MLD) using the entrainment rate value $3.0\;m{\cdot}day^{-1}$. The spring blooms in the southern and northern regions closely related to deepening of a winter surface MLD. In the southern region where MLD was shallow and phytoplankton spring bloom occurs one month in advance to the northern region where MLD was deep. The amount of light increases within the MLD during the onset of stratification and water temperature increases faster in spring in the southern region than the northern region. Decrease of phytoplankton was mainly affected by zooplankton grazing in the southern region and by nutrient exhaustion in the northern region. The fall bloom in the two regions was caused by the nutrient availability and entrainment on the phytoplankton.

Enhancement of Hydroxylamine Reactivity of Bacteriorhodopsin at High Temperature

  • Sonoyama, Masashi;Mitaku, Shigeki
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.299-301
    • /
    • 2002
  • Recent denaturation experiments of bacteriorhodopsin (bR) in the dark and under illumination at high temperatures revealed that irreversible thermal bleaching occurs above ~ 70°C and the preceding reversible structural changes in the dark above 60°C are closely related to irreversible photobleaching observed in the same temperature range (Yokoyama et al. (2002). J Biochem. 131,785). In this study, structural properties of bacteriorhodopsin (bR) at high temperatures were extensively probed by hydroxylamine reactivity with the Schiff base in the dark and hydrogen-deuterium (H-D) exchange in the peptide groups. In the Arrhenius plot from kinetics measurements of the hydroxylamine reaction, a good linear relationship between the reaction time constant and the inverse of the absolute temperature was observed below 60°C, while significant increase started above 60°C, suggesting that remarkable increase in water accessibility of the Schiff base in the temperature region. FT-IR spectroscopic studies on the H-D exchange suggested increase in the deuterium exchanges rate of the peptide hydrogen in the same temperature region.

  • PDF

Correlation of Droplet Flow Rate and Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region (강제대류 및 핵비등영역에 있어서 액적유량과 분무냉각 열전달의 상관관계에 관한 연구)

  • Kim, Yeung-Chan
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.143-148
    • /
    • 2008
  • In the present study, the correlation between the Nusselt number and Reynolds number was developed for forced convection and nucleate boiling region in spray cooling. Also the effect of droplet subcooling on spray cooling heat transfer was investigated. Full cone spray nozzles were employed for spray cooling experiment, and water and FC-77 were used for developing the correlation. From the experimental results, the correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for water and FC-77.

  • PDF

Geotechnical Properties of Muskeg Soil for Construction Machinery Distributed in Oil-sand Areas (캐나다 오일샌드 분포지역에서의 유체기계 주행성능 평가를 위한 지반공학적 특성 분석)

  • Hong, Seung-Seo;Kim, YoungSeok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.29-32
    • /
    • 2016
  • A series of laboratory tests were conducted to investigate the geotechnical engineering characteristics of muskeg soil for construction machinery widely distributed in cambridge region in Canada which makes problems in construction works. Physical characteristics of cambridge region muskeg soil were measured in terms of such categories as nature water content, organic content, specfic gravity, liquid limit, and plasticity index. As the test result, it was found that nature water content, organic content, specific gravity, liquid limit, plasticity index, and compression strength were 50.8~343.8%, 12.1~42.5%, 1.76~2.57, 46.6~440.2%, 25.6~280.5, $0.665{\sim}1.537kg/cm^2$, respectively.

A study on the boiling heat transfer of R-113 in a horizontal tube (수평관내 R-113 냉매의 비등열전달에 관한 연구)

  • 최병철;김원녕;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.67-77
    • /
    • 1986
  • The information on the heat transfer characteristics, flow pattern and pressure drop, are very important for the desing of general heat exchanger, refrigerating system, air conditioning system and energy recovery system. In these systems, water or lubricating oil contained in working fluid affects greatly the flow and heat transfer condition and this phenomena must be considered in the practical design. An experiment has been performed for studying the flow and heat transfer characteristics of the forced convective horizontal flow of R-113 under the range of the liquid single phase state to the boiling flow state. Basic experimental results are obtained in the case that water or lubricating oil does not contaminate in the test fluid. Experimental results are as follows; (1) The local heat transfer coefficients in the nucleate boiling region and transition boiling region are almostly ten times as large as that of liquid single phase flow. (2) The measured heat transfer coefficient in the present experimental range is relatively agreed well with the predicted value from the various experimental results for the boiling flow.

  • PDF

An Experimental Study of The Effects of The Mixing Vane on Air-water Mixed Flow

  • Kim, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.331-336
    • /
    • 1996
  • The effects of a mixing vane on air-water mixed flow have been experimentally studied in this work, to investigate the basic mechanisms that the mixing vane affects critical heat flux (CHF). Experiment was performed for various flow rates focusing on bubbly flow and annular flow patterns. Acrylic tube (1.7m long, 11 mm I.D.) and the split vane type mixing vane were used, and ring-type conductance probes were used to measure the liquid film thickness in annular flow. Experimental results show that, (a) bubbly-to slug flow transition and churn-to-annular flow transition occur respectively near the mixing vane compared to the tests without mixing vane, (b) in bubbly flow region, the mixing vane breaks the bubbles into smaller ones and forwards bubbles to the center region of the tube by the centrifugal force, (c) the liquid film thickness in annular flow is decreased near the mixing vane for mass fluxes.

  • PDF