Dose Reduction Factors for High-Exposure Tasks at Korean Pressurized Water Reactors

  • Changju Song;Tae Young Kong;Seongjun Kim;Jinho Son;Jiung Kim;Jaeok Park;Hee Geun Kim;Yongkwon Kim;Hyungkwon Jung
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.23-33
    • /
    • 2024
  • This study was conducted to analyze the characteristics of three high-exposure tasks performed by radiation workers in Korean pressurized water reactors (PWRs) and to identify factors that reduce their exposure during work. Three high-exposure tasks were selected based on a previous study. In this previous study, nozzle dam installation and removal, eddy current testing, and manway opening and closing were determined as high-exposure tasks through normalization (radiation dose per unit time). Based on the analysis of the characteristics of the high-exposure tasks in this study, the high-exposure tasks were steam generator-related tasks performed inside and outside the water chamber. This study analyzed the reduction factors for high-exposure tasks and suggested improvements in terms of time, distance, and shielding. The use of the characteristics of high-exposure tasks and their dose reduction factors enables Korean PWRs to optimize radiation protection for workers who receive relatively high doses.

Waste Load Allocation of Hwanggujicheon Watershed Using Optimization Technique (최적화기법을 이용한 황구지천유역의 오염부하량 할당)

  • Cho, Jae Heon;Chung, Wook Jin;Lee, Jong Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.728-737
    • /
    • 2005
  • Water quality of the Hwanggujicheon is poor because of the rapid housing and development in the large area of the basin. Establishment of water quality management strategy, based on the pollution sources survey and pollutant loads estimation, has to be established for the preservation of the stream water quality of the region. In this study, waste load allocation model to achieve the water quality goal of the stream and the optimization of pollutant load reduction, was developed. Nonpoint pollutant loads calculated by runoff model in the previous study are utilized for pollutant loads estimation of the drainage areas in this study. From the application result of the allocation model, water quality goals of the Hwanggujicheon that can be achieved as a matter of fact are BOD 8 mg/L. To achieve these goals, 23% of effluent BOD loads have to be reduced in the basin.

Compatibility inspection for the way for Decision about Bight Flow Profile of Standard River Design (하천설계기준의 만곡부 수면형 결정 방법에 대한 적용성 검증)

  • Choi, Han-Kuy;Che, Hong-Gi;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.43-51
    • /
    • 2006
  • Through the result of calculating the deviation between the value calculated from two-dimensional number formula, one-dimensional number interpretation, and curving part water surface type calculation method, we could confirmed that the deviation is reduced more than 50% when we use curving part water surface type calculation method. Also it was confirmed that there occurs the reduction rate of maximum 59% as the result of comparing with one-dimensional number interpretation since the reduction rate of safe room height was 20%, in 500 CMS of flood water quantity when we planted the construction of levee by curving part water surface type calculation method. And therefore, we have confirmed that the curving water surface type calculation method can be used as a simple formula in rivers with water quantity less than 500 CMS that flows in and out in Jess than 90 degree angle.

  • PDF

A Study on Cost Benefit Analysis Optimization Model for Water Distribution Network Rehabilitation Project of Taebaek Region (태백권 배수관망 개량사업의 비용효과분석 최적화 모델 연구)

  • Kim, Taegon;Choi, Taeho;Kim, Kyoungpil;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.395-406
    • /
    • 2015
  • This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.

Introduction to a New Sample Preparation Apparatus (H/Device) for Measurement of Hydrogen Isotope Composition of Natural Water (신(新) H/Device를 이용한 자연수의 수소동위원소비 측정)

  • Park, Seong-Sook;Yun, Seong-Taek;So, Chil-Sup
    • Economic and Environmental Geology
    • /
    • v.31 no.3
    • /
    • pp.265-271
    • /
    • 1998
  • In the hydrologic and hydrochemical studies of natural waters, oxygen and hydrogen isotope compositions of waters are very important to elucidate the origin and circulation pattern of water in the hydrologic system. The hydrogen isotope analysis of waters usually has been undertaken through the reduction of water to form hydrogen gas using pure metals (in general, zinc and uranium). In 1996, a new apparatus (H/Device) was developed to prepare the water samples (by the reduction with Cr metal) without some intrinsic problems that may yield incorrect and/or inaccurate data, and was installed at 1997 in the Center for Mineral Resources Research (CMR) in Korea University. However, the optimistic conditions of preparation and analysis of samples has not been established. In this paper, we introduce the efficiency of H/Device to obtain accurate hydrogen isotope values of water, and discuss both the optimum conditions including the effective reduction time and the probable mixing (memory) effect between successive samples. We obtained large amounts of a laboratory working standard (KUW; Korea University Water) with the average ${\delta}D_{SMOW}$ value of $-42.1{\pm}1.0$$(1{\sigma})$.

  • PDF

Spatial Interpolation of Rainfall by Areal Reduction Factor (ARF) Analysis for Hancheon Watershed

  • Kar, Kanak Kanti;Yang, Sung Kee;Lee, Junho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.427-427
    • /
    • 2015
  • The storm water management and drainage relation are the key variable that plays a vital role on hydrological design and risk analysis. These require knowledge about spatial variability over a specified area. Generally, design rainfall values are expressed from the fixed point rainfall, which is depth at a specific location. Concurrently, determine the areal rainfall amount is also very important. Therefore, a spatial rainfall interpolation (point rainfall converting to areal rainfall) can be solved by areal reduction factor (ARF) estimation. In mainland of South Korea, for dam design and its operation, public safety, other surface water projects concerned about ARF for extreme hydrological events. In spite of the long term average rainfall (2,061 mm) and increasing extreme rainfall events, ARF estimation is also essential for Jeju Island's water control structures. To meet up this purpose, five fixed rainfall stations of automatic weather stations (AWS) near the "Hancheon Stream Watershed" area has been considered and more than 50 years of high quality rainfall data have been analyzed for estimating design rainfall. The relationship approach for the 24 hour design storm is assessed based on ARF. Furthermore, this presentation will provide an outline of ARF standards that can be used to assist the decision makers and water resources engineers for other streams of Jeju Island.

  • PDF

Evaluation of Water Cycle Improvement in LH Institute Using SWMM-LID Model (SWMM-LID 모델을 이용한 토지주택연구원의 물순환 개선효과 평가)

  • Jung, Jong-Suk;Jung, Kwang-Wook;Kang, Suman;Hyun, Kyong-Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.308-315
    • /
    • 2018
  • SWMM-LID was calibrated with flow monitoring data in LHI to evaluate runoff after LID application. The flow rate in the B basin was estimated to be 0.94 and 6.15 for O/S and $D_v$, respectively. In the A and C basins, the difference between the observed and simulated data was greater than in the B basin. As a result of runoff reduction efficiency by the application of LID facilities, the change of infiltration increased from 34.6 % to 45.8 % in the entire watershed, and the runoff decreased from 58.8 % to 46.3 %. In the runoff reduction of each LID facility, rain garden E showed the highest effect with 99.9 % and bioretention B showed the lowest effect with 27.5 %. In order to evaluate the efficiency of each LID facility, a comparison is made between the pore volume (V) of the LID and the catchment area (A). The runoff showed a runoff reduction effect of about 70 % above the 0.1 volume/area (V/A) value. As a result of examining the runoff reduction with LID facilities by the LID module of SWMM, a reasonable design is possible by reflecting the appropriate LID volume to drainage area.

Analysis of the Efficiency of Non-point Source Pollution Managements Considering the Land Use Characteristics of Watersheds (유역의 토지이용 특성을 고려한 비점오염원 관리방안 적용에 따른 저감 효율 분석)

  • Choi, Yujin;Lee, Seoro;Kum, Donghyuk;Han, Jeongho;Park, Woonji;Kim, Jonggun;Lim, Kyoungjae
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.405-422
    • /
    • 2020
  • Land use change by urbanization has significantly affected the hydrological process including the runoff characteristics. Due to this situation, it has been becoming more complicated to manage non-point source pollutions caused by rainfall. In order to effectively control non-point sources, it is necessary to identify the reduction efficiency of the various management method based on land use characteristics. Thus, the purpose of this study is to analyze the reduction efficiency of non-point source pollution management practices targeting three different watersheds with the different land use characteristics using the Soil and Water Assessment Tool (SWAT). To do this, the vulnerable subwatersheds to non-point source pollution occurrence within each watershed were selected based on the streamflow and water quality simulation results. Then, considering the land use, low impact development (LID) or best management practices (BMPs) were applied to the selected subwatersheds and the efficiency of each management was analyzed. As a result of analysis of the non-point source pollution reduction efficiency, when LID was applied to urban areas, the average reduction efficiencies of SS, NO3-N, and TP were 5.92%, 4.62%, and 10.35%, respectively. When BMPs were applied to rural areas, the average reduction efficiencies of SS, TN and TP were 35.45%, 4.37%, and 10.16%, respectively. The results of this study can be used as a reference for determining appropriate management methods for non-point source pollution in urban, rural, and complex watersheds.

Characteristics of Non-point Pollution Runoff in Mandae, Gaa, and Jaun Districts and Evaluation of Reduction Projects (만대·가아·자운지구 비점오염 유출특성 분석 및 저감사업 평가)

  • Woo, Soo-Min;Kum, Dong-Hyuk;Hong, Eun-Mi;Lim, Kyoung-Jae;Shin, Min-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.65-77
    • /
    • 2022
  • Due to muddy water from the highland fields upstream of Soyangho Lake, the Mandae, Gaa, and Jawoon have been redesignated as NPS management areas. This study aims to evaluate the adequacy and supplementation points of the implementation plan by analyzing the operation status of muddy water generation and reduction facilities through on-site investigations by NPS management area to achieve the effective nonpoint pollution reduction goal in the implementation of the implementation plan established in 2020. The SS load calculated based on the survey results from July to October 2019 from 2017 showed a decreasen in 2019 compared to 2017. Both and the Jawoon were analyzed to have decreased. However, the amount of precipitation also decreased by about 27%, so it was judged that the effect of the reduction project was not significant. As a result of the detailed investigation of abatement facilities, about 86% of the 793 facilities installed in the management area were evaluated as 'good'. As a result of a detailed investigation by subwatersheds, subwatersheds 105 and 106 in the Mandae were analyzed as apprehensive subwatersheds. appeared to fall. In addition, it was analyzed that the effect of reducing muddy water in the Mandae district was insufficient due to the high ratio of leased farmers, lack of efforts to reduce turbid water in leased farmland, conversion to annual crops, and neglect of bare land. In the case of Gaa district, although the abatement facilities are concentrated in the upstream, muddy water was also found to be severe.

Estimation of Sludge Reduction and Nitrogen Removal Possibility using OSA Process (OSA 공정을 이용한 하수슬러지 감량화 및 질소제거 가능성 평가)

  • Joo, Jae-Young;Yoon, Su-Chul;Nam, Duck-Hyun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.497-503
    • /
    • 2008
  • The Oxic-Settling-Anaerobic(OSA) process is a modified activated sludge processes for sludge reduction. It is evaluated that the sludge production in OSA process can decrease to 88% because of biomass decay and kinetic parameter($Y_H$ 0.237mgVSS/mgCOD, $b_H$ $0.195d^{-1}$) in anaerobic reactor, when compared with CAS process. However, it has problems caused by sludge reduction such as increase of nutrient loading. In case that the anoxic condition through the introduction of the intermittent aeration for the enhancement of nitrogen removal ability build up and enough rbCOD is suppled, maximum 88% of nitrogen is removed in the OSA process. If the OSA process optimizing the intermittent aeration cycle is applied to the separate sewage system with high rbCOD fraction, it can be converted to advanced process in terms of the sludge reduction and nitrogen removal, simultaneously.