• Title/Summary/Keyword: Water Reduction

Search Result 4,858, Processing Time 0.038 seconds

An Application of Toxicity Test to Water Management and Water Treatment (수질관리와 수처리에의 독성시험의 응용)

  • Kim, Berm-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.639-646
    • /
    • 2005
  • In this research, we tried to develop the application method to water management and treatment using toxicity test method. When we measure the toxicity of environmental samples, we have to decide whether we take some countermeasures to reduce the toxicity or not. The first issue is how to set these action levels in each bioassays. A new idea was attempted to authorize indirect approach of each bioassays through the response characteristics against mixture of chemicals in water quality standard. The significant response in the cell-growth-inhibition bioassay was detected for standards-mixture(STDs). For acute toxicity assay, STDs-based implicit correlation between risks to humans and bioassay data showed a rational approach to set action levels in practical management. A simple model was proposed to describe and predict the changes in the total toxicity based on the concentrations of toxic-controlling chemicals during the ozonation of landfill leachates. On the basis of this simple model, toxicity reduction was predicted for pre-aggregation treatment before ozonation and ozone concentration during the ozonation. The method proposed in this study would be useful in optimizing water treatment processes and their running conditions in terms of the toxicity reduction efficacy.

Degradation Characteristics of Filament-Winding-Laminated Composites Under Accelerated Environmental Test (필라멘트 와인딩 복합적층재의 환경가속 노화시험 평가)

  • Kim, Duck-Jae;Yun, Young-Ju;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.295-303
    • /
    • 2007
  • Degradation behaviors of filament-winded composites have been evaluated under the accelerated environmental test of high temperature, water immersion and thermal impact conditions. Two kinds of laminated composites coated by an urethane resin have been used: carbon-fiber reinforced epoxy(T700/Epon-826, CFRP) and glass-fiber reinforced phenolic (E-glass/phenolic, GFRP). For tensile strength of $0^{\circ}$ composites, CFRP showed little degradation while GFRP did high reduction by 25% under the influence of high temperature and water However for water-immersed $90^{\circ}$ composites tensile strength of both CFRP and GFRP showed high reduction. Bending strength and modulus of $90^{\circ}$ composites were largely reduced in water-immersion as well as high temperature environment. Urethane coating on the composite surface improved the bending properties by 20%, however hardly showed such improvement for water-immersed $90^{\circ}$ composites. In case of shear strength and modulus, both CFRP and GFRP showed high reduction by water-Immersion test but did a slight increase by high temperature and thermal impact conditions.

A Study on reduction plan of drainage noise for water closet (화장실 배수소음 저감 연구)

  • Lee, J.W.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.165-171
    • /
    • 2000
  • The study about a drainpipe of water closet was performed as reduction plan on drainage noise for water closet, which of noise in plumbing systems was being indicated the major point at issue in apartment houses. A drainpipe of water closet is divided into a sleeve, a joint elbow and a traversing pipe, through the result of experiment, for an effective noise reduction in a drainpipe a threefold joint elbow is proposed among parts. And through the experiment of performance with glasswool, the removal of glasswool should be in the economical efficiency aspect.

  • PDF

A Fundamental study of Fine Dust Reduction of Dust Inhibitor using Water Soluble Polymer (수용성 폴리머를 사용한 비산먼지 방지제의 미세먼지 저감에 관한 기초적 연구)

  • Lim, Sung-Gyu;Cho, In-Seong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.38-39
    • /
    • 2020
  • Since a lot of fugitive dust is generated at construction and civil engineering construction sites in Korea, the fine dust regulation at construction sites has been strengthened in accordance with the implementation of the Special Act on Fine Dust Reduction. In a construction site, water is generally sprayed to temporarily reduce the generation rate of scattered dust, but there is a problem that when water evaporates, it scatters again. In this study, the performance of a scattering dust inhibitor incorporating a polymer that stabilizes the ground and reduces the rate of scattering dust by forming a polymer film even when water evaporates using a polymer and a surfactant was evaluated.

  • PDF

Effects of Washing and Storage Temperature on Quality and Safety of Washed Shell Eggs (세척 수 및 보관온도가 세척 식용란 품질과 안전에 미치는 영향)

  • Choi, Bum-Geun;Min, Ji-Hyeon;Yoon, Ki-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.27 no.1
    • /
    • pp.78-87
    • /
    • 2017
  • The objective of this study was to investigate the effects of various washing waters on the quality and safety characteristics of eggs during storage. Eggs were washed with tap water, 100 ppm of sodium hypochlorite, or 30 ppm of slightly acidic electrolyzed water and stored at $10^{\circ}C$ and $20^{\circ}C$. Effects of various washing waters on reduction of Salmonella Enteritidis and aerobic plate counts and survival of S. Enteritidis on egg shells were also analyzed at $10^{\circ}C$ and $20^{\circ}C$ for 25 days. As an index of quality, haugh unit, weight reduction, and pHs of egg white and egg yolk were measured. Reduction percentages of haugh unit and weight were higher at $20^{\circ}C$ than at $10^{\circ}C$. Egg qualities were less affected by tap water, slightly acidic electrolyzed water, and sodium hypochlorite, regardless of storage temperature. The greatest reductions in aerobic plate counts and S. Enteritidis were observed with slightly acidic electrolyzed water. The level of S. Enteritidis on egg shells gradually decreased during 20 days of storage at both $10^{\circ}C$ and $20^{\circ}C$, whereas S. Enteritidis survived longer at $20^{\circ}C$ than at $10^{\circ}C$. S. Enteritidis was not detected in eggs at $10^{\circ}C$, 2.13 log CFU/g of S. Enteritidis was detected in eggs washed with sodium hypochlorite after 20 days of storage at $20^{\circ}C$, indicating that S. Enteritidis penetrated into the egg shell during storage at $20^{\circ}C$. In conclusion, slightly acidic electrolyzed water increased microbial reduction and least affected quality of washed eggs. Thus, slightly acidic electrolyzed water can be recommended for washing of graded eggs, at retail markets.

Effect of Water Induction on the Performance and Exhaust Emissions in a Diesel Engine (II)

  • Ryu, Kyunghyun;Oh, Youngtaig
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1640-1647
    • /
    • 2004
  • This study was to investigate the effects of water induction through the air intake system on the characteristics of combustion and exhaust emissions in an IDI diesel engine. The fuel injection timing was also controlled to investigate a method for the simultaneous reduction of smoke and NOx when water was injected into the combustion chamber. The formation of NOx was significantly suppressed by decreasing the gas peak temperature during the initial combustion process because the water played a role as a heat sink during evaporating in the combustion chamber, while the smoke was slightly increased with increased water amount. Also, NOx emission was significantly decreased with increase in water amount. A simultaneous reduction in smoke and NOx emissions was obtained when water was injected into the combustion chamber by retarding more 2$^{\circ}C$A of the fuel injection timing than without water injection.

A Study on the Simultanious Reduction of Smoke and NOx by Water Injection through Intake Port in Diesel Engine (디젤기관에서 흡기관내로의 물 분사에 의한 매연과 NOx의 동시 저감에 관한 연구)

  • Ryu, Kyung-Hyun;Oh, Young-Taig
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2186-2191
    • /
    • 2003
  • This study is to investigate the effects of water induction through the air intake system on the characteristics of combustion and exhaust emissions in diesel engine. The effects of water induction through the air intake port were considered in IDI diesel engine in this study. The formation of NOx was significantly suppressed by decreasing the gas peak temperature during the initial combustion process because the water play a role as a heat sink during evaporating in the combustion chamber, but the smoke was slightly increased with increased water amount. Also, NOx significantly decreased with increase in water amount. A simultaneous reduction in smoke and NOx emissions can be obtained when water is injected into the combustion chamber by retarding the fuel injection timing more than without water injection.

  • PDF

Effect of Salt Level in Water on Feed Intake and Growth Rate of Red and Fallow Weaner Deer

  • Ru, Y.J.;Glatz, P.C.;Bao, Y.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 2005
  • Under a typical Mediterranean environment in southern Australia, the evaporation rate increases significantly in hot summers, resulting in highly saline drinking water for grazing animals. Also in the cropping areas, dryland salinity is a problem. Grazing animals under these environments can ingest excessive amount of salt from feed, drinking water and soil, which can lead to a reduction in growth rate. To understand the impact of high salt intake on grazing deer, two experiments were conducted to assess the effect of salt levels in drinking water on feed intake and growth rate of red and fallow weaner deer. The results revealed that fallow deer did not show any abnormal behaviour or sickness when salt level in drinking water was increased from 0% to 2.5%. Feed intake was not affected until the salt content in water exceeded 1.5%. Body weight gain was not affected by 1.2% salt in drinking water, but was reduced as salt content in water increased. Compared with deer on fresh water, the feed intake of red deer on saline water was 11-13% lower when salt level in drinking water was 0.4-0.8%. An increase in salt level in water up to 1% resulted in about a 30% reduction in feed intake (p<0.01). Body weight gain was significantly (p=0.004) reduced when salt level reached 1.2%. The deer on 1% salt tended to have a higher (p=0.052) osmotic pressure in serum. The concentration of P, K, Mg and S in serum was affected when salt level in water was over 1.0%. The results suggested that the salt level in drinking water should be lower than 1.2% for fallow weaner deer and 0.8% for red weaner deer to avoid any reduction in feed intake. Deer farmers need to regularly test the salt levels in drinking water on their farms to ensure that the salt intake of grazing deer is not over the levels that deer can tolerate.

Reduced Post-Chlorine Dosage Required for Disinfection: Improvement with Ozonation and GAC Process (오존 및 입상활성탄 도입시 후염소 주입량 저감효과 분석)

  • Baek, Young-Ae;Joe, Woo-Hyeun;Kim, Jong-Moon;Choi, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.445-452
    • /
    • 2007
  • This study was carried out to examine effect of post-chlorine dosage reduction by ozonation and GAC process in the field plant for 3years in the "G" water purification plant in Seoul. And it is to compare GAC with BAC process in removal effects of TOC, THMs, THMFP, $UV_{254}$. As a result, chlorine dosage of ozonation and GAC(=BAC) is less demand than GAC. Seasonal reduction of chlorine demand is from about 37% to 59% with BAC, and from 24 to 46% with GAC. Higher reduction in BAC could be achieved. The efficiency of chlorine demand reduction with ozonation was depending on the organic carbon removal. $UV_{254}$ concentration is less about 0.13~0.74L/mg.m in BAC than GAC. Therefore, the combination of ozonation and GAC was more effective in reducing post-chlorine than the single GAC. TOC was also monitored, and results show that a linear relationship between TOC and chlorine demand is appropriate under each treatment process. It means that removal of organic matter(TOC) from finished water is necessary to reduce post-chlorine dosage in clear well and to minimize order of chlorine in distribution systems.

A Study on the Drag Reduction Effect and Heat Transfer Enhancement of Non ionized Surfactant and Water Mixture in a Circular Pipe Flow (비이온계 계면활성제 첨가수에 대한 관내 유동저항 감소 및 열전달 촉진에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.552-557
    • /
    • 2007
  • This paper has dealt with the effect of non ionized surfactant and water mixture on drag reduction and heat transfer enhancement in a circular pipe flow with experimentally. The test section was consisted of stainless steel pipe with inside diameter of 16mm. The wire coil was used to increase heat transfer in a pipe and the on ionized surfactant(Oleyl Dihydroxyethyl Amino Oxide, ODEAO) was used to reduce the drag force of water mixture with surfactant. The main parameters of this experiment were diameter and pitch of wire coil and the ratio of test section length and horizontal wire coil length. In this experiment, the acquired results were 1) Drag reduction effect existed in this ODEAO-water mixture, 2) Friction factor and heat transfer were increased with insertion the heat transfer enhancement coil, 3) With increasing of pitch ratio, heat transfer was decreased, and 4) Heat transfer was decreased by the decreasing of inserting coil diameter.