• 제목/요약/키워드: Water Level Measurement

검색결과 490건 처리시간 0.028초

수질 영향평가 신뢰수준 향상을 위한 낙동강 유역 미관측 지점에서의 일사량 추정: 수정형 Angstrom모형과 투과율모형의 비교 (Estimation of Daily Solar Radiation at the Missing Point for Water Quality Impact Assessment in Nakdong River Watershed: Comparison of Modified Angstrom Model and Transmittance interpolation Model)

  • 이길하
    • 환경영향평가
    • /
    • 제21권1호
    • /
    • pp.219-227
    • /
    • 2012
  • Daily solar radiation is essential for water resources planning and environmental impact assessment. However, radiation data is not commonly available in Korea other than in big cities, and there has been no direct measurement for rural areas where water resources planning and environmental impact assessment is usually most needed. In general, missing radiation data is estimated from nearby regional stations within a certain distance, and this study compared two dominant methods (modified Angstrom equation and transmittance interpolation method) at six stations in Nakdong River watershed area. Two methods shows a similar level of accuracy but the transmittance interpolation method is likely to be superior in that there is no need for any measurement element since the modified Angstrom equation require the sunshine hour measurement. This study will contribute to improve water resource and water quality management in Nakdong River watershed.

잔향수조 내 수중음원의 음원레벨 추정기법에 관한 실험연구 (Experimental Study on Source Level Estimation Techniques of Underwater Sound Source in Reverberant Water Tank)

  • 김국현
    • 한국해양공학회지
    • /
    • 제33권4호
    • /
    • pp.358-363
    • /
    • 2019
  • The acoustic power is used as a primary index characterizing underwater sound sources and could be defined by its source level. The source level has been assessed using various experimental techniques such as the reverberation time method and reverberant tank plot method. While the reverberation time method requires reverberation time data extracted in a preliminary experiment in a reverberant water tank, the reverberant tank plot method only needs acoustic pressure data directly obtained at the reverberation water tank. In this research, these experimental techniques were studied in comparative experiments to estimate the source levels of underwater sources in a reverberant water tank. This paper summarizes the basic theories and procedures of these experimental techniques and presents the experimental results for an underwater source in a long cuboid water tank using each technique, along with a discussion.

대형증발계용 매시간 증발 기록계 개발에 관한 연구 (A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan)

  • 이부용
    • 한국환경과학회지
    • /
    • 제10권5호
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

강우사상과 침수 실측자료를 이용한 도시침수 양상 관계분석 (Analysis of the urban flood pattern using rainfall data and measurement flood data)

  • 문혜진;조재웅;강호선;이한승;황정근
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.95-95
    • /
    • 2020
  • Urban flooding occurs in the form of internal-water inundation on roads and lowlands due to heavy rainfall. Unlike in the case of rivers, inundation in urban areas there is lacking in research on predicting and warning through measurement data. In order to analyze urban flood patterns and prevent damage, it is necessary to analyze flooding measurement data for various rainfalls. In this study, the pattern of urban flooding caused by rainfall was analyzed by utilizing the urban flooding measuring sensor, which is being test-run in the flood prone zone for urban flooding management. For analysis, 2019 rainfall data, surface water depth data, and water level data of a street inlet (storm water pipeline) were used. The analysis showed that the amount of rainfall that causes flooding in the target area was identified, and the timing of inundation varies depending on the rainfall pattern. The results of the analysis can be used as verification data for the urban inundation limit rainfall under development. In addition, by using rainfall intensity and rainfall patterns that affect the flooding, it can be used as data for establishing rainfall criteria of urban flooding and predicting that may occur in the future.

  • PDF

시화호 환경 변화에 따른 강재 표면의 부식특성 변화 (Variation of Corrosion Properties on the Steel Surface by Environmental Changes in Shihwa Lake)

  • 박준무;이승효;우상균;추인엽;이명훈
    • 한국표면공학회지
    • /
    • 제51권5호
    • /
    • pp.316-324
    • /
    • 2018
  • Harsh seawater environment is subdivided into marine atmosphere, splash zone, tidal zone, submerged zone and bottom of sea depending on the exposed part. Since corrosion rate depends on the conditions of the exposed parts, proper protection and maintenance for each parts are essential for long-term use of steel structures in seawater environment. For steel structures which were installed in Shiwha Lake, a special maintenance system is required to guarantee its long-term durability and safety. As the tidal power plant has recently been operated, the salinity has risen due to the rapid influx of seawater upstream into Sihwa Lake and the corrosion tendency of the structure is variable according to the water level fluctuation. In this study, corrosion properties of steel structures under water level fluctuation was evaluated by corrosion rate measurement, visual inspection and natural potential measurement and their durability and life management were discussed in view of the effect of variation in of seawater level fluctuations in Shihwa Lake.

Development of a System of r Regular Evaluation of Streamflow Data (KOwaco's Regular Streamflow Appraising System)

  • Noh, jae-Kyoung
    • 한국농공학회지
    • /
    • 제42권
    • /
    • pp.24-30
    • /
    • 2000
  • A system for evaluating streamflow data (KORSAS) was developed, and is operated using PC based Windows to help the hydrological observation practitioner's working in Korea Water Resources Corporation (KOWACO). This system has modules including; DB access and data management, flow measurement arranging, H-Q relation deriving, area rainfall calculating, flow calculating, and flow evaluating modules. Evaluation of observed streamflow is accomplished through the following processes. First, hourly streamflow data is calculated from water level data stored in a DB server by applying the rating relationship between water level and flow rates derived from the past flow measurements. Second, hourly areal rainfal data is calculated from point data stored in the DB server by applying Thiessen networks. Third, hydrographs are displayed on a daily, weekly, monthly, or seasonal duration basis, and are compared to hydrographs of reservoir inflow, hydrographs at water level observation stations and hydrographs derived from simulated results using models.

  • PDF

목포해역 개발에 따른 항내 조석변화 (Tidal Changes in the Harbor due to the Development of Mokpo Coastal Zone)

  • 정명선;정대득;신승호;이중우
    • 한국항만학회지
    • /
    • 제11권1호
    • /
    • pp.113-120
    • /
    • 1997
  • Tidal changes in Mokpo harbor and its adjacent coastal waters caused by the coastal development including the construction of the Youngsan, Youngam, and Gumho Estuary Barrages had been predicted previously. Since then, the construction work for these estuary barrages had been completed and it was available to get water level variations from the continuous measurement at the Mokpo tidal station. This study deals with the analysis of water level variation from the observed data by the harmonic analysis and mathematical treatment. Some comparisons between the observed water level changes and the predicted by the numerical model are made, which was not supported before. The result shows that the trend of the water level changes are following well the previously predicted variations.

  • PDF

빗물펌프장 계측방식과 운영 로직에 따른 거동 비교 연구 (A comparative study on the performance of pumping station by changing measurement methods and operational logic)

  • 이건영;백현욱;류재나;김태형;오재일
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.915-925
    • /
    • 2012
  • On-off control performance of target pumping station was experimented by changing measurement methods for storage level or inflow and operating logic for control system setting. Four scenarios with different measurement methods and operational logic were examined in the Matlab/Simulink environment. Controller's on-off control repetition that was frequent before has been reduced and more effective and stable system operation was found to be possible with the scenarios. Moreover, defensive operation enforced prevention of floods by changing measurement methods enabled economic operation that made an utmost use of storage volumes.

저수지 수위 정밀 측정에 의한 댐 유입량 자료 개선 (Improvement of Inflow Estimation Data by Precise Measurement of Water Level in Reservoir)

  • 박지창;김남;류경식
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.309-314
    • /
    • 2009
  • A accurate reservoir inflow is very important as providing information for decision making about the water balance and the flood control, as well as for dam safety. The methods to calculate the inflow were divided by the directed method to measure streamflow from upstream reservoirs and the indirected method to estimate using the correlation of reservoir water level and release. Currently, the inflow of multi-purpose dam is being calculated by the indirect method and the reservoir water level to calculate the storage capacity is being used by centimeters(cm) units. Corresponding to the storage volume of 1cm according to scale and water level of multi-purpose dam comes up to from several 10 thousand tons to several million tons. If it converts to inflow during 1 hour, and it comes to several hundred $m^3/sec$(CMS). Therefore, the inflow calculated on the hourly is largely deviated along the water level changes and is occurred minus value as the case. In this research, the water level gage has been developed so that it can measure a accurate water level for the improvement for the error and derivation of inflow, even though there might be various hydrology and meteorologic considerations to analyse the water balance of reservoir. Also, it is confirmed that the error and the standard derivation of data observed by the new gage is decreased by 89,6% and 1/3 & 87% and 2/3 compared to that observed by the existing gage of Daecheong and Juam multi-purpose dam.

Error Check Algorithm in the Wireless Transmission of Digital Data by Water Level Measurement

  • Kim, Hie-Sik;Seol, Dae-Yeon;Kim, Young-Il;Nam, Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1666-1668
    • /
    • 2004
  • By wireless transmission data, there is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error check algorithm in order to decrease the data's distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error check algorithm for error check of transmission data. This study is also that investigation and search for error check algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro process in the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which can get permission to use by Frequency Law made by Korean government

  • PDF