• 제목/요약/키워드: Water Intake Tower

검색결과 32건 처리시간 0.025초

폐쇄공간 송수관로 수역내 민물담치의 생태특성 (Ecological Characteristics of Limnoperna fortunei in an Enclosed Facility of Water Supply Pipeline)

  • 신이숙;정선아;신재기
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.420-427
    • /
    • 2013
  • In this study, the ecological characteristics of Limnoperna fortunei were surveyed as a preceding research to solve the problem such as biofouling or biowaste caused by those organisms in the closed water pipeline. Limnoperna fortunei was collected not in the main reaches of Somjin River but inside and outside of the intake tower which is located in the lower part of Sueo Reservoir. The dense populations were found at the inlet mouth and near part of the pipeline. Their byssuses were formed as a thick and tightly interwind mat. The rusted parts of the pipeline hold relatively more shells than those of the normal parts. Average count of the numbers ranged $12.1{\sim}136.5ind./m^2$ through the sampling stations (A,B and C). The amount of attached shells at each station were A=386, B=258, and C=71, respectively. The relationships of shell height-length and shell length-width were proportional. The majority sizes in each station ranged A=20.01~22.00 mm (33.9%), B=10.01~14.00 mm (51.2%), and C=18.01~20.00 mm (22.5%), 24.01~26.00 mm (21.1%), respectively. Most of the bigger size of shells on C station was found dead. The ecological habitat seemed less suitable for Limnoperna fortunei when they located farther away from the intake tower of reservoir. From now on, it is necessary to consider the continuous monitoring of this organism.

취수문비의 안정성에 관한 연구 (A Study on the Stability of Intake gate in a Dam)

  • 곽영균;고성호;강민구
    • 한국유체기계학회 논문집
    • /
    • 제11권1호
    • /
    • pp.46-51
    • /
    • 2008
  • A stability analysis has been made for a newly designed gate of intake tower of reservoir. The analysis is composed of finding the natural frequency of the gate and the frequency induced by water flowing over and through the gate. ANSYS is employed to calculate the natural frequency of the gate and SC/Tetra is utilized for calculating flow field around the gate, which in turn gives the frequency of pressure force fluctuation on the gate. In addition to the safety analysis, the present study presents how the gate selectively intakes a muddy water layer located in the middle depth of reservoir.

연초호의 인공 순환 장치 운영에 의한 수질 개선 효과 분석 (Effect of Artificial Aeration System on Water Quality of Yeoncho Lake)

  • 서동일;황현동;이은형;허우명
    • 상하수도학회지
    • /
    • 제18권3호
    • /
    • pp.357-365
    • /
    • 2004
  • Effect of artificial circulation on amelioration of water quality in Yeoncho Lake was analyzed using summer data between 1991-2002. Two sites, intake tower area where aeration systems are concentrated in and near the inlet of reservoir were selected for comparison in this study. Summer averages between may and september Showed that aeration system might be beneficial in the improvement of water quality of BOD5, COD, and TN while Chl-a concentration and transparency did show opposite pattems. Wilcoxon's singed rank test for matched pair indicated slight increase of BOD5 and COD concentrations in the vicinity of intake tower while other variables did not show any significant differences from data of inlet of reservoir. During the study, it was found that the following subjects need to be investigated for more detailed analysis. 1) Dynamic pollutant loading from outside and inside the lake, 2) Biological, Chemical and Physical lake data when aeration systems are in and not in operation and 3) Radius of influence of aeration system.

심층 방류하는 안동호 내 탁수의 거동 (Spatial and Temporal Dynamics of Turbid Water in Hypolimnetic Discharging Reservoir)

  • 박재충;정석원;박정원;김호준
    • 생태와환경
    • /
    • 제41권3호
    • /
    • pp.360-366
    • /
    • 2008
  • 본 연구는 심수층의 고정 취수구를 통해 방류하는 안동댐을 대상으로 1일 최대 99.4 mm, 총 299.1 mm인 단일사상의 강우로 유입된 고탁수의 호소 내 시 공간적인 거동과 방류수의 탁도가 감소하는 경향을 조사하였다. 유입된 고탁수는 중류지점부터 호소 바닥에서 이탈되어 중층 밀도류로 최하류까지 이동하였다. 강우 이전의 호소 내 탁도는 10 NTU 이하의 균일한 분포를 보였으나 강우에 의해 수심 16 m에 최고 290 NTU의 고탁수대가 형성되었다. 고탁수는 강우 후 3일부터 방류수의 탁도를 상승시켰으며 5일째에 129 NTU로 최고 탁도를 보였다. 댐까지 이동한 탁수층은 취수구 상부 5 m 이내의 수심에 최고 농도로 분포하였으며 하류 방류에 의해 탁수층의 두께와 농도가 감소하였다. 방류수의 탁도가 30 NTU까지 감소하는데 38일, 강우 이전의 상태로 회복되는데 87일이 소요되었으며, 감소경향의 상관계수는 각각 0.96, 0.97이었다. 중층에서 밀도류를 형성한 고탁수는 취수구 직상부에 분포하면서 취수구 방향으로 점차 유인되어 하류로 배출되었으며 호소 바닥으로의 침강은 일어나지 않았다. 안동호로 유입된 고탁수는 심층에 위치한 취수구를 통해 효과적으로 배출되므로 취수구 위치는 고탁수 배제에 적정한 것으로 판단된다.

상수원수 내 이취미 제거효율 향상을 위한 분말활성탄 투입지점의 평가 (Evaluation on the Locations of Powdered Activated Carbon Addition for Improvement of Taste and Odor Removal in Drinking Water Supplies)

  • 김영일;이상진;배병욱
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.341-348
    • /
    • 2007
  • The efficiency of powdered activated carbon (PAC) for removing taste and odor (T&O) in drinking water supplies is dependent on the contact time, quality of mixing, and the presence of competing compounds. All of these are strongly influenced by the stage in the treatment process at which the PAC is added. In conventional water treatment plants (WTPs), PAC is commonly added into the rapid mixing basin where chemicals such as coagulants, alkaline chemicals, and chlorine, are simultaneously applied. In order to prevent interference between PAC and other water treatment chemicals, alternative locations for addition of PAC, such as at transmission pipe in the water intake tower or into a separated PAC contactor, were investigated. Whatever the location, addition of PAC apart from other water treatment chemicals was more effective for geosmin removal than simultaneous addition. Among several combinations, the sequence 'chlorine-PAC-coagulant' produced the best result with respect to geosmin removal efficiency. Consequently, when PAC has to be applied to cope with T&O problems in conventional WTPs, it is very important to prevent interference with other water treatment chemicals, such as chlorine and coagulant. Adequate contact time should also be given for adsorption of the T&O compounds onto the PAC. To satisfy these conditions, installation of a separated PAC contactor would be the superior alternative if there is space available in the WTP. If necessary, PAC could be added at transmission pipe in the water intake tower and still provide some benefit for T&O treatment.

댐내 수온성층 파괴를 위한 산기식 수중폭기설비 성능향상 실증연구 (Positive Research About Water Aeration Improvement to Break Thermal Stratification of Dam)

  • 박종호;라병필
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.37-42
    • /
    • 2014
  • In Korea while the dam or reservoir is an important water resource, the value of this water resource is deteriorating by thermal-induced stratification. To ameliorate the water quality of reservoir by breaking stratification the use of air diffuser system is now widespread in Korea. According to the previous research, dynamics of bubble plume and destratification efficiency depended upon two dimensionless groupings; Mh and Pn suggested by Asaeda et al (1993). However, these two variables only include Q, N, H, g, u. and installed Boryeong reservior in appropriate width of water aeration, air dose and number of installations after calculating by applying these figures. This paper is performed to find out effect analysis about water aeration improvement to break thermal stratification.

횡성호 식물플랑크톤에 대한 간헐식 폭기의 영향과 선택취수 (Effect on Phytoplankton by Hydraulic-Gun-Aerators and Selective Withdrawal in Hoengseung Reservoir)

  • 최일환;김학철
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.15-26
    • /
    • 2007
  • Surface water is the main drinking water source in Korea. Algal bloom caused by phytoplankton in reservoir is common event in every summer season. To prevent or control the algal blooms, artificial circulation system has been adopted in many reservoirs, including Hoengseung reservoir. Total 7 hydraulic-gun-aerators were installed around the intake tower in Hoengseung reservoir since 2000. This study is to elucidate the effects of hydraulic-gun-aerators on phytoplankton bloom, pH, DO, temperature and evaluate the selective withdrawal and vertical distribution of phytoplankton by means of submersible fluorescence probe, which features high correlation with a standard ISO method (r=0.90, P<0.0001) for chlorophyll-a quantification.

대청호의 취수탑 주변의 이화학적${\cdot}$생물학적 상태에 대한 계절강우의 영향 (Influences of Seasonal Rainfall on Physical, Chemical and Biological Conditions Near the Intake Tower of Taechung Reservoir)

  • 서진원;박석순;안광국
    • 생태와환경
    • /
    • 제34권4호통권96호
    • /
    • pp.327-336
    • /
    • 2001
  • 1993년 7월부터 1994년 8월까지 대청호 내 문의취수탑에서 조류의 엽록소 양 및 투명도에 대한 영양염류 및 현탁물의 영향을 평가하기 위해 물리적, 화학적, 생물학적 요소들이 측정되었다. 1993년 여름기간 동안 집중 강우는 수체의 회석효과(전기전도도=$88\;{\mu}S/cm$),최소의 총질소와 총인 질량 비 (<40),그리고 최대의 총인 농도($59\;{\mu}g/L$)를 야기시켰고, 계절들 가운데 최고점의 엽록소 ($79\;{\mu}g/L$)와 최소의 투명도(<1.5m)를 초래하였다. 이와 동시에 유기현탁물(VSS)과 무기현탁물(NVSS)질량비는 최대 (13.0)였으며, 이것은 감소된 투명도가 식물성 플랑크톤 성장과 연관된 생물학적인 혼탁도로부터 주로 기인되었다는 것을 제시하였다. 반면, 1994년 여름기간동안의 극심한 가뭄은 1993년 여름보다 높은 전기전도도(>$120\;{\mu}S/cm$)와 물의 투명도(>2m),그리고 낮은 총인과 엽록소(<$10\;{\mu}g/L$)를 초래하였다. 영양염류에 대한 엽록소의 회귀분석에 따르면, 엽록소의 변이는 총질소 ($R^2=0.29$)보다는 총인 ($R^2=0.46$)에 의해 설명되었다. 총질소와 총인의 질량비는 조사기간동안 $39{\sim}222$범위에 속하였으며, 총질소의 농도 보다는 총인의 농도에 의해 결정되었다. 조사기간동안 두 영양염류의 농도와 총질소 대 총인의 질량 비는 엽록소의 계절 주기성이 주로 강우의 분포에 반영된 인(Phosphorus)의 농도에 의해 결정된다는 것을 의미하였다. 집중강우 기간동안의 인유입의 저지는 취수탑에서 식수를 위한 보다 나은 수질을 제공할 것으로 사료된다.

  • PDF

수치모형을 이용한 하상변동 연구 (A Study on the Sediment Movement Using Numerical Models)

  • 임창수;손광익;이재준;윤세의
    • 한국수자원학회논문집
    • /
    • 제32권2호
    • /
    • pp.131-142
    • /
    • 1999
  • 본 연구에서는 금강 부여취수구를 중심으로 한 금강본류의 상하류에 대한 수리적 특성 및 유사론적 특성을 파악하기 위하여 1차원 및 준2차원 수치해석적 유사모의 분석을 실시하였다. 1차원 유사이동 수치모형 모의분석은 HEC-6를 사용하였으며 준2차원 유사이동 수치모형 모의분석은 GSTARS를 이용하여 1988년부터 1996년까지에 대한 유사이동 수치모형 모의분석을 실시하여 프로그램의 현장 적용가능성을 분석한 후 1988년부터 2001년까지에 대한 예측을 통하여 금강 부여취수탑 주변에 대한 유사이동 현황분석을 실시하였다. 1988년 실측된 하상 실측 자료를 초기 하상자료로 하여 13년 후인 2001년의 장기하상변동을 예측한 결과 전체적으로는 금강본류를 따라 퇴적 및 침식이 반복되는 현황을 보이고 있고 금강 부여취수구 주변 및 취수구 하류부근에서는 최심하상고가 높아져 계속 퇴적되는 추세를 보여주고 있었다.

  • PDF

비선형거동과 구조물유체상호작용을 고려한 취수탑 내진모델의 보수성평가 (Conservation for the Seismic Models of Intake Tower with Nonlinear Behaviors and Fluid Structure Interaction)

  • 이계희;이명규;홍관영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.17-24
    • /
    • 2020
  • 본 연구에서는 물로 둘러싸인 철근콘크리트 취수탑에 대한 비선형내진해석을 수행하였다. 구조물 주변의 유체를 고려하기 위하여 부가질량 및 CEL을 이용한 유체구조물 상호작용 모델을 구성하였다. 이 때 부가질량모델은 음해법을 사용하였고 유체구조물 상호작용 모델은 양해법을 사용하였다. 입력운동은 동일한 인공지진을 재현주기에 따라 500년, 1000년, 2400년에 해당하도록 크기를 조절하였다. 유체를 고려한 모델의 보수성을 평가하기 위하여 유체를 고려하지 않은 모델을 구성하여 참조해로 삼았다. 콘크리트와 철근의 재료모델은 항복후의 비선형 거동을 고려할 수 있도록 선정하였고 ABAQUS를 이용하여 해석을 수행하였다. 해석결과 얻어진 구조물의 가속도응답스펙트럼을 비교한 결과 주변 유체의 영향은 구조물의 기본 진동수에 해당하는 첨두의 진동수와 첨두값의 크기를 감소시키는 것으로 나타났다. 하지만 부가 질량 모델에서는 고차 진동수에 해당하는 첨두값에는 영향을 미치지 못하였다. 유체의 영향을 고려한 단면모멘트는 부가질량모델의 경우 참조 모델의 응답에 비하여 크게 증가하였다. 특히 선형거동이 지배적인 작은 크기의 지진응답에 대해서 이러한 증폭이 크게 발생하였다. 유체구조물 상호작용 모델의 경우 낮은 진동수성분을 가진 단면모멘트는 참조모델의 응답에 비하여 증폭이 발생하나, 높은 진동수 성분을 단면 모멘트는 증폭이 발생하지 않았다. 이러한 결과를 종합하여 볼 때 부가질량모델의 보수성이 유체구조물상호작용 모델이 비해 큰 것으로 평가되었다.