• Title/Summary/Keyword: Water Infiltration Rate

Search Result 200, Processing Time 0.023 seconds

A study on Runoff Characteristics of Non-point Pollutant with Rainfall Intensity - A case of fowls manure - (강우강도에 따른 비점오염원 유출 특성에 관한 연구 - 계분을 중심으로 -)

  • Lee, Min-Woo;Lee, Young-Shin
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.91-97
    • /
    • 2009
  • The fowls manure is using as fertilizers for farmland because of enough nutrients. However, excess nutrients can be washed off during a storm and affected on nearby waterbodies. In this paper, the runoff characteristics from farmland were studied to determine the washoff mass. A lab-scale reactor was designed to estimate the surface runoff and infiltration rates according to the rainfall intensity. Surface runoff water did not occur at 10mm/hr rainfall intensity, but some runoff occurred at 20mm/hr rainfall intensity. At 32.4mm/hr rainfall intensity, it shows the highest pollutant concentrations such as 686mg/L for $BOD_5$ and at 630mg/L $COD_{Mn}$. The pollutant as based on fowls manure compost was highly washed-off by subsurface water at 32.4mm/hr rainfall intensity, however the concentration was largely decreased at 43.2mm/hr rainfall intensity. The summary of the results is that the highest wash-off concentrations value shows at 32.4mm/hr rainfall intensity for $BOD_5$ and at 67.1mm/hr for T-N and T-P.

  • PDF

Hydraulic Conductivity in Multi-layered Soil amended with Cow Manure Compost (우분퇴비 처리가 다층구조 토양의 수리전도도에 미치는 영향)

  • 김필주;이병렬;김건엽
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.3
    • /
    • pp.59-67
    • /
    • 1997
  • To investigate the effects of organic matter and soil depth on soil water flow in a multi-layered soil, the saturated hydraulic conductivities(Ksat) were measured from the single- and multi-layered soil columns, that the soils were mixed with the oven-dried cow manure compost(CMC) at 4 different ratios such as 0, 2, 4, and 6% on a weight basis. The measured hydraulic conductivities(Ksat) were compared with theoretical hydraulic conductivity (Keff calculated by Jury's equation of effective hydraulic conductivity. In the single layered soil column saturated hydraulic conductivities(Ksat) were significantly decreased with increasing the application rate of compost. In the multi-layered the soil columns Ksat was also decreased with increasing rate of compost and soil depth. Calculated Keff showed the similar results of Ksat as obtained from the measured Ksat, whereas steadily increased with increasing soil depth. Therefore, modification of Jury's equation should be required to adapt theoretical Keff for Held application.

  • PDF

Physiological and Histological Changes of Overfeeding-induced Obese Rainbow Trout Oncorhynchus mykiss (사료 과다공급으로 유도된 비만 무지개송어(Oncorhynchus mykiss)의 생리·조직학적 변화)

  • Park, Jiyeon;Roh, Heyong Jin;Park, Junewoo;Jeong, Dahye;Lee, Mu Kun;Kim, Do-Hyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.688-696
    • /
    • 2022
  • Obesity could cause immune-physiological disorders in fish. Yet, little is known about the impact of obesity on stress and histological responses. This study aimed to determine histological and physiological changes in and vulnerability of overfeeding-induced obese rainbow trout Oncorhynchus mykiss exposed to stress condition. Control, intermediate and overfed groups were fed at 1.5, 2.5 and 3.09% of their body weight per day, respectively, for eight weeks. Weight gain, body mass index, hepatosomatic index and serological parameters, and histology of liver were measured in five fish from each group at week 0, 2, 4, and 8. At week 8, 20 fish from each group were exposed to heat stress by increasing water temperature at a rate of 3℃ per day from 15 to 25℃ and maintaining the final temperature for 10 days. Overall, overfed fish showed significantly higher weight gain, body mass index, and serological parameters than those of fish in the other groups. Fish in the overfed and intermediate groups displayed multifocal infiltration of inflammatory cells in hepatic parenchyma. Mortality rate and serological parameters of fish in the overfed group exposed to heat stress were significantly higher than those of fish in the other groups, indicating increased vulnerability to environmental stress.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF

Groundwater Flow Modeling in a Riverbank Filtration Area, Deasan-Myeon, Changwon City (창원시 대산면 강변여과수 취수부지 주변의 지하수 유동 모델링)

  • Hamm, Se-Yeong;Cheong, Jae-Yeol;Kim, Hyoung-Su;Hahn, Jeong-Sang;Cha, Yong-Hoon
    • Economic and Environmental Geology
    • /
    • v.38 no.1
    • /
    • pp.67-78
    • /
    • 2005
  • Riverbank filtration has been used in advanced countries for 150 years. In Korea, investigations for producing riverbank filtrate started in the Han River, Nakdong River, Geum River, Yeongsan River and Seomjin River basins in the 1990s. The lower part of the Nakdong River has a poorer water quality than the upper part of the river. A water balance analysis and groundwater flow modeling were conducted for the riverbanks of the Nakdong River in Daesan-Myeon, Changwon City. The results of the water balance analysis revealed the groundwater infiltration rate into the aquifer to be 245.26 mm/year (19.68% of the average annual precipitation, 1,251.32 mm). Direct runoff accounts for 153.49 mm/year, evapotranspiration is 723.95 mm/year and baseflow is 127.63 mm/year. According to the groundwater flow modeling, 65% of the total inflow to the pumping wells originates from the Nakdong River, 13% originates from the aquifer in the rectilinear direction, and 22% originates from the aquifer in the parallel direction. The particle tracking model shows that a particle moving from the river toward the pumping wells travels 100 m in 50 days and a particle from the aquifer toward the pumping wells travels 100 m in 100 days.

Assessing Groundwater Vulnerability Using DRASTIC Method and Groundwater Quality in Changwon City (DRASTIC과 지하수 수질에 의한 창원시 지하수 오염취약성 평가)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Moo-Jin;Kim In-Soo;Hwang Han-Seok
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.631-645
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in industrial and residential/commercial areas of the city of Changwon, using DRASTIC technique and groundwater data. The DRASTIC technique was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. Mostly the industrial area has higher DRASTIC indices than the residential/commercial area. However, a part of the residential/commercial area having much groundwater production and great drawdown is more contaminated in groundwater than other industrial and the residential/commercial areas even if it has lowest DRASTIC indices in the study area. It indicates that groundwater contamination in urban areas can be closely related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is as low as 0.40. On the other hand, the correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well distribution density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other human-made factors such as groundwater withdrawal rate and well distribution density per unit area as well as the existing seven DRASTIC factors.

Sensitivity Analysis of the SWMM Model Parameters Based on Design Rainfall Condition (설계강우조건에 따른 SWMM모형 매개변수의 민감도 분석)

  • Lee, Jong-Tae;Hur, Sung-Chul;Kim, Tae-Hwa
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.213-222
    • /
    • 2005
  • This study is a sensitivity analysis of the parameters which affect the simulation results under various design rainfall conditions, using the SWMM model, for three selected basins in urban areas. The sensitivity of the peak flow rate is defined by $S_Q$ (=1.0 - (min. ratio of peak flow rate/max. ratio of peak flow rate)), and the rainfall conditions are classified in terms of design rainfall frequency, duration, and distribution. The simulation results show that in most conditions the parameters - the impermeable area ratio, the sewer slope, and the initial infiltration capacity - have more significant effects on the results than other parameters. As the design rainfall frequency increases, the sensitivity of the sewer slope and sewer roughness increases, while the parameters related with the surface runoff decrease. When the rainfall duration increases, the sensitivities of most parameters of surface runoff and sewer flow decrease. Also, at the 1st quarterly Huff rainfall distribution condition, the impermeable area ratio has high sensitivity, but at the 4th quarterly condition the parameters related with sewer flow show higher sensitivities. These tendencies can be explained by considering the procedure for computing the effective rainfall and kinematic wave on the surface and sewer flow.

Effects of Mulching Materials on Physical Properties of Soil and Grain Yield of Sesame (멀칭 재료가 참깨재배토양의 생리성 및 종실수량에 미치는 영향)

  • Kim, Wook-Han;Hong, Byung-Hee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.3
    • /
    • pp.260-269
    • /
    • 1986
  • This experiment was conducted to investigate the effect of mulching materials on the emergence rate, root dry weight and grain weight of sesame using variety Poong Nyun Ggae and also their effects on physical properties of soil, evapotranspiration and weed growth on the respective plots were studied. The effect of soil water holding capacity at mulching with polyethylene film and straw increased 5.4%, 2.8% to non-mulched plot respectively. The maximum soil temperature was raised up to 4$^{\circ}C$ by applying clear film and was dropped down to 7$^{\circ}C$ by straw. The minimum soil temperature was raised up to 2$^{\circ}C$ by clear film and was dropped down to 3$^{\circ}C$ by straw. In the early stage, the soil physical properties of clear film mulching were better than those of non mulching, and so was in emergence rate. In the late stage, soil strength was high at non mulching, and soil porosity, soil aeration and water infiltration rate were high at film and straw mulchings. Total root dry weight was great at clear film mulching, and root dry weight was concentrated mainly in the upper 10 cm of soil profile. The amount of weeds collected was the least at black film mulching. There were of little difference in evapotranspiration among treatments. The grain yield of sesame was increased to 57% by polyethylene film and 25% by straw mulching.

  • PDF

Water Quality in a Drainage System Discharging Groundwater from Sangdae-ri Water Curtain Cultivation Area near Musimcheon Stream, Cheongju, Korea (무심천 인근 상대리 수막재배지에서 지하수 사용 후 배출되는 최종 배수로 물의 수질 특성)

  • Moon, Sang-Ho;Kim, Yongcheol;Hwang, Jeong
    • Economic and Environmental Geology
    • /
    • v.48 no.5
    • /
    • pp.409-420
    • /
    • 2015
  • The Sangdae-ri riverside around Musimcheon stream, flowing through Gadeok-myon of Cheongju City, is one of the representative strawberry fields employing water curtain cultivation (WCC) in Korea. In this area, annual groundwater use for WCC has been calculated by a few methods. On the assumption that all the water flowing through the final ditch may be mostly composed of groundwater, the discharge rate in it can be used as a good proxy for assessing the groundwater use. However, in the study area, the final ditch was set up in an unpaved state near and parallel to Musimcheon stream. Under such circumstances, the drainwater is likely to be influenced by infiltration and/or inflow of nearby stream. Hence, we examined whether or not stream water has influenced water flowing out through the final ditch in respect of ion concentrations or field parameters such as T, pH and electrical conductivity (EC) values. The period of measuring field parameters and sample collection was from February 2012 through February 2015. The drainwater in the final ditch did not show the average quality of groundwater, but similar quality of stream water in respect of pH, EC, ion contents and water type. From this, it is suggested that measuring the flow rate of the final ditch should not be directly used for assessing groundwater use in the study area. In addition, because of its sensitivity to ambient temperature, water temperature proved not to be appropriate for estimating the interaction between ditch and stream. For accuracy, additional methods will be needed to calculate mixing ratios between stream and ground water within drainage system.

Monitoring of grout material injected under a reservoir using electrical and electromagnetic surveys (전기비저항 및 전자탐사를 이용한 저수지 하부에 주입된 그라우트 재료의 모니터링)

  • Suzuki, Koichi;Oyama, Takahiro;Kawashima, Fumiharu;Tsukada, Tomoyuki;Jyomori, Akira
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • In order to reduce leakage from a reservoir, a large amount of cement milk (grout) was injected from boreholes drilled around the shores of the reservoir, and monitored to establish the infiltration of cement milk into the bedrock under the reservoir. From laboratory tests using rock core samples, it was revealed that the resistivity of cement milk is much lower than that of the groundwater at this location. Therefore, it was expected that the resistivity of the zones filled with cement milk would be significantly reduced. Geophysical surveys are expected to be suitable methods to check the effectiveness of grouting in improving the water-retaining performance of a reservoir. DC electrical surveys (seven in total) and two Controlled Source Audio-frequency Magneto-Telluric (CSAMT) surveys were conducted along survey lines in the reservoir to monitor the infiltration of cement milk during the grouting. Extremely low resistivity zones ($10\;{\Omega}m$ or less) were observed in resistivity sections obtained by 2D inversion. The zones are inferred to be fractured zones filled with cement milk. In sections showing the rate of change of resistivity, three zones that showed significant change showed gradual expansion to deeper parts as the grouting progressed. These zones correspond to highly permeable zones detected by Lugeon tests at grout boreholes. We have confirmed that it is possible to measure the resistivity change by DC electrical and CSAMT surveys from the surface of the reservoir. It seems that such monitoring results could be reflected in future grouting plans.