• Title/Summary/Keyword: Water Hazard

Search Result 674, Processing Time 0.028 seconds

Study on Health Risk Assessment of Non-carcinogenic Chemicals in Drinking Water (음용수 중 유해 화학 물질에 대한 위해성 평가에 관한 연구 - II. 비발암성 화학 물질을 중심으로 -)

  • Chung, Yong;Shin, Dong-Chun;Kim, Jong-Man;Park, Seong-Eun;Yang, Ji-Yeon;Lee, Ja-Koung;Hwang, Man-Sik;Park, Yeon-Shin
    • Environmental Analysis Health and Toxicology
    • /
    • v.10 no.1_2
    • /
    • pp.37-46
    • /
    • 1995
  • The purpose of this research is to estimate a safe environmental level of human exposure to thresholding-acting toxicants in drinking water and recommend the acceptable levels and management plans for maintaining good quality of drinking water' and protecting health hazard. This research has been funded as a national project for three years from 1992 to 1995. This study(the second year, 1993-1994) was conducted to monitor 39 species of noncarcinogenic chemicals such as volatile organic compounds(VOCs), polynuclear aromatic hydrocarbens(PAHs), pesticides and heavy metals of drinking water at some area in six cities of Korea, and evaluate health risk due to these chemicals through four main steps (hazard identification, exposure assessment, dose-response assessment and risk characterization) of risk assessment in drinking water. In hazard identification, 39 species of non-carcinogenic chemicals were identified by the US EPA classification system. In the step of exposure assessment, sampling of tap water from the public water supply system had been conducted from 1993 to 1994, and 39 chemicals were analyzed. Inclose-response assessment for non-carcinogens, reference doses(RfD) and lifetime health advisories(HAs) of lifetime acceptable levels were calculated. In risk characterization of detected chemicals, the hazard quotients of noncarcinogens were less than one except those of manganese and iron in D city.

  • PDF

Multivariate assessment of the occurrence of compound Hazards at the pan-Asian region

  • Davy Jean Abella;Kuk-Hyun Ahn
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.166-166
    • /
    • 2023
  • Compound hazards (CHs) are two or more extreme climate events combined which occur simultaneously in the same region at the same time. Compared to individual hazards, the combination of hazards that cause CHs can result in greater economic losses and deaths. While several extreme climate events have been recorded across Asia for the past decades, many studies have only focused on a single hazard. In this study, we assess the spatiotemporal pattern of dry compound hazards which includes drought, heatwave, fire and wind across Asia for the last 42 years (1980-2021) using the historical data from ERA5 Reanalysis dataset. We utilize a daily spatial data of each climate event to assess the occurrence of such compound hazards on a daily basis. Heatwave, fire and wind hazard occurrences are analyzed using daily percentile-based thresholds while a pre-defined threshold for SPI is applied for drought occurrence. Then, the occurrence of each type of compound hazard is taken from overlapping the map of daily occurrences of a single hazard. Lastly, a multivariate assessment are conducted to quantify the occurrence frequency, hotspots and trends of each type of compound hazard across Asia. By conducting a multivariate analysis of the occurrence of these compound hazards, we identify the relationships and interactions in dry compound hazards including droughts, heatwaves, fires, and winds, ultimately leading to better-informed decisions and strategies in the natural risk management.

  • PDF

A study on health risk assessment for small-scale water works in Gyeongnam province from 2014 to 2016 (2014~2016년 동안 경남지역 소규모 급수시설에 대한 건강 위해성 평가 연구)

  • Park, Ju-Won;Son, Song-Ee;Lee, Hu-Jang
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.227-237
    • /
    • 2018
  • Objectives: This study was investigated the characteristics of small-scale water works (SWW) in Gyeongnam area and conduct a health risk assessment of water-quality inspection items unfitted for water-quality standards (WQS). Methods: The characteristics of SWW in Gyeongnam province were analyzed using the data of SWW in the last three years (2014~2016) published in National Waterworks Information System. In addition, the health risk assessment for inspection items unfitted for WQS was carried out in four steps: hazard identification, dose-response assessment, exposure assessment, and risk characterization. Results: The total number of SWW in Gyeongnam area was gradually decreased from 2014 to 2016. In addition, drinking water sources of SWW were in the order of ground water, valley water, spring water, surface water, and river-bed water. The number of points unfitted for WQS in SWW by year was 22, 45, and 18 in 2014, 2015, and 2016, respectively, and a total of 112 points were found to unfit for WQS in SWW during 2014~2016. The hazard quotient (HQ) for fluoride, nitrate nitrogen, boron in the unfitted points for WQS was more than 1.0, and the mean values for turbidity and color in points unfitted for WQS were 2.38 nephelometric turbidity unit and 16.25 color unit, respectively. Conclusions: The HQ for fluorine, nitrate nitrogen and boron was more than 1.0 in points unfitted for WQS among SWW in Gyeongnam area, and the turbidity and the color degree exceeded WQS, which mean that there is a possibility of harmful impacts on the human health.

An experimental study on the fire hazard of Sheath Heater (시즈히터의 화재위험성에 관한 실험 연구)

  • Kim, Hakjoong
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.511-517
    • /
    • 2014
  • Recently, the fire by sheath heater has been occurred frequently on winter season. The sheath heater has simple internal structure and boils water simply. Therefore, the use of sheath heater has been increased. In this study, found the fire hazard property of sheath heater from understanding the fire mechanism through the experiment to get the measure for decreasing the occurrence of fire. For the analysis of the fire hazard property of the sheath heater, performed the test of temperature change and ignition temperature by using current product. On the result of test, the sheath heaters are the most dangerous appliance to arise fire. Water temperature controller attached to sheath heater is not sufficient to prevent overheating it. The sheath heater should have level switch of water and temperature controller for heater itself to shut off the power supply. Because the cause of fire by sheath heater is overheating itself in the situation of lack water.

A study on the application of water safety plans for the hazard risk management of tap water (수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구)

  • Kim, Jinkeun;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

Inundation Map at Imwon Port with Past and Virtual Tsunamis (과거 및 가상 지진해일에 의한 임원항의 침수예상도)

  • Kim, Tae-Rim;Cho, He-Rin;Cho, Yong-Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • The scale of disaster and damage witnessed in the 2004 Indian Ocean Tsunami and the 2011 Great East Japan Tsunami has motivated researchers in developing foolproof disaster mitigation techniques for safety of coastal communities. This study focuses on developing tsunami hazard map by numerical modeling at Imwon Port to minimize losses of human beings and property damage when a real tsunami event occurs. A hazard map is developed based on inundation maps obtained by numerical modeling of 3 past and 11 virtual tsunami cases. The linear shallow-water equations with manipulation of frequency dispersion and the non-linear shallow-water equations are employed to obtain inundation maps. The inundation map gives the maximum extent of expected flooded area and corresponding inundation depths which helps in identifying vulnerable areas for unexpected tsunami attacks. The information can be used for planning and developing safety zones and evacuation structures to minimize damage in case of real tsunami events.

A Study on the Hazard and Risk Analysis of Hospital in Korea - Focused on Local Medical Centers (의료기관의 위험도 분석 조사 - 지역공공의료원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon;Lee, Hyunjin;Kim, Taeyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.31-39
    • /
    • 2022
  • The purpose of this study is to analyse the hazard risk by examining the magnitude and severity of each type of hazard in order to mitigate and prepare for disasters in medical facilities. Methods: The hazard risk analysis for hazard types was surveyed for team leaders of medical facilities. The questionnaire analyzed data from 27 facilities, which were returned from 41 Local Medical Centers. Results: When looking at the 'Risk' by category type of hazard, the influence of health safety and fire/energy safety comes first, followed by natural disaster, facility safety, and crime safety. On the other hand, as for 'Magnitude', facility safety and crime safety come first, followed by health safety, fire/energy safety, and natural disasters. Most of the top types of disaster judged to have high hazard in medical facilities are health types. The top five priorities of hazard in medical facilities, they are affected by the geographical and industrial conditions of the treatment area. In the case of cities, the hazard was found to be high in the order of infectious disease, patient surge, and wind and flood damage. On the other hand, in rural areas, livestock diseases and infectious diseases showed the highest hazard. In the case of forest areas, the hazard was high in the order of wildfire, fire accident, lightning, tide, earthquake, and landslide, whereas in coastal areas of industrial complexes, the hazard was high due to fire, landslide, water pollution, marine pollution, and chemical spill accident. Implications: Through the research, standards will be established for the design of hospitals with disaster preparedness, and will contribute to the preparation of preemptive measures in terms of maintenance.

Characteristics and Combined Sewer Overflows (합류식 하수관거의 유출 특성 분석 조사)

  • An, Ki-Sun;Jang, Sung-Ryong;Kwon, Young-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.747-753
    • /
    • 2010
  • It follows in quality and sewage exclusion method of the investigation objective sector and the Combined Sewer Overflows which is suitable in regional characteristics and the confluence area against the rainfall initially a flow and the medulla and measurement - it analyzes the initial rainfall outflow possibility control plan which is suitable in the domestic actual condition and it proposes the monitor ring plan for the long-term flow and pollution load data accumulation. From the research which it sees the Infiltration water/Influent water and CSOs investigation it passes by the phase of hazard chain and Namwon right time 4 it does not hold reverse under selecting, Measurement it used the hazard automatic flow joint seal Sigma 910 machine and in case 15 minute interval of the I/I, it measured a flow at case 5, 15 minute standing of the CSOs. The water quality investigation for the water leakage investigation of the I/I and the sewage from the point which is identical with flow measurement during on-the-spot inspection duration against 6 items which include the BOD sampling and an analysis, when the rainfall analysis for CSOs fundamental investigation analyzed against 18 items which include the BOD sampling. Consequently, for the optimum interpretation invasion water / inflow water of the this investigation area day average the lowest flow - water quality assessment veterinarian optimum interpretation hazard average per day - lowest flow - it averages a medulla evaluation law department one lowest flow evaluation technique and it selects, it presentation collectively from here it gets, position result with base flow analysis of invasion water / inflow water.

Evaluation of Typhoon Hazard Factors using the EST Approach (EST 기법에 의한 태풍의 재해위험인자 평가)

  • Lee, Soon-Cheol;Kim, Jin-Kyoo;Oh, Kyoung-Doo;Jun, Byong-Ho;Hong, Il-Pyo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.10 s.159
    • /
    • pp.825-839
    • /
    • 2005
  • Application of the EST approach for the simulation of the risk-based typhoon hazard potential is described in this paper. For six selected cities In the Korean peninsula, EST simulations for one hundred years were performed one hundred times using historical typhoon data as a training data set. The analytical results of EST simulations were then post-processed to estimate the means, standard deviations, and ranges of variation for the maximum wind velocities and the daily rainfalls. From the comparison of the averages of the wind velocities for the 100 year recurrence interval typhoons, the wind hazard potential of them was revealed to be highest for Mokpo among the six cities, followed by Busan, Cheju, Inchun, Taegu, and Seoul in descending order For the flood hazard potential associated with a typhoon, Busan was ranked to be the highest hazard potential area, followed by Mokpo, Cheju, Seoul, Inckun, and Taegu. In terms of the overall typhoon hazard potential, cities in the southern coastal regions were identified as being exposed to the most severe typhoon hazard.