• 제목/요약/키워드: Water Drop

검색결과 908건 처리시간 0.029초

정수장 마이크로 소수력 발전기 적용에 대한 연구 (A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant)

  • 김종겸;박영진;김일중
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

Raindrop Size Distribution Over Northeastern Coast of Brazil

  • Tenorio Ricardo Sarmento;Kwon Byung-Hyuk;Silva Moraes Marcia Cristina da
    • Journal of information and communication convergence engineering
    • /
    • 제4권1호
    • /
    • pp.46-52
    • /
    • 2006
  • Precipitation measurement with ground-based radar needs an information of the raindrop size distribution (RSD) characteristics. A 10-month dataset was collected in tropical Atlantic coastal zone of northeastern Brazil where the weather radar was installed. The number of drop was mainly recorded in 300 - 500 drop $mm^{-3}$, of which the maximum was registered around 1.1 mm drop diameter.

Localisation of embedded water drop in glass composite using THz spectroscopy

  • Mieloszyk, Magdalena;Majewska, Katarzyna;Ostachowicz, Wieslaw
    • Smart Structures and Systems
    • /
    • 제21권6호
    • /
    • pp.751-759
    • /
    • 2018
  • Glass fibre reinforced polymers (GFRP) are widely exploited in many industrial branches. Due to this Structural Health Monitoring systems containing embedded fibre optics sensors are applied. One of the problems that can influence on composite element durability is water contamination that can be introduced into material structure during manufacturing. Such inclusion can be a damage origin significantly decreasing mechanical properties of an element. A non-destructive method that can be applied for inspection of an internal structure of elements is THz spectroscopy. It can be used for identifications of material discontinuities that results in changes of absorption, refractive index or scattering of propagating THz waves. The limitations of THz propagation through water makes this technique a promising solution for detection of a water inclusion. The paper presents an application of THz spectroscopy for detection and localisation of a water drop inclusion embedded in a GFRP material between two fibre optics with fibre Bragg grating sensors. The proposed filtering method allowed to determine a 3D shape of the water drop.

전산유체역학(CFD)를 활용한 정수공정에서 길이가 긴 유공관 설계 (Design of the long perforated pipe in water treatment process using CFD)

  • 조영만;유수전;노재순;빈재훈
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.295-305
    • /
    • 2010
  • Role of the perforated pipe is to drain the water with equal pressure and velocity through the holes of perforated pipe. The perforated pipe is being used in many processes of water treatment system, however, the design parameter of perforated pipe is not standardized in korea. In this study, we have found the design parameter of perforated pipe in the water treatment system using the Computational Fluid Dynamics (CFD). The uniformity of outflow from the perforated pipe is directly affected according to area ratio(gross area of holes/surface area of the perforated pipe). In other words, the uniformity of outflow is improved as area ratio is smaller. Also, at the same area ratio, the uniformity of outflow is improved as number of holes is increase. Specially, in case of the two holes per length of pipe diameter(2/D) shows the most uniformity of outflow and the best hydraulic with the smaller pressure drop. The uniformity of outflow is aggravated and the pressure drop of pipe is decrease as length of pipe is longer. In case of that pipe length is 10m and above, the pressure drop decreased about 30% when diameter ratio is 40% with 0.2% of area ratio by comparison with 0.1% of area ratio.

소성 점토의 침탄 처리에 따른 물성 변화에 관한 연구 (Characteristics of Calcined Clay by Carburization Treatment)

  • 김상명;김기호
    • 한국표면공학회지
    • /
    • 제41권2호
    • /
    • pp.63-68
    • /
    • 2008
  • Traditionally and generally used calcined clay was carburized, and its characteristics were studied. Carburization treatment was performed by the thermally decomposed carbon and the deposit carbon which occur in a so called 'Boudouard reaction $(2CO{\rightarrow}CO_2+C)'$ at fuel combustion process in a closed-type furnace. The color of the carburized calcine clay changed from yellow to black, and the carbon component revealed as crystalline graphite by the X-ray diffraction test. The weight of the carburized calcine clay decreased to about 4 wt.% by the 1st heating to $1400^{\circ}C$ in air but it does not decreased by the 2nd heating of the same conditions. By the carburization treatment, the water absorption changed from 13 wt.% to 6 wt.%, and the contact angle for water drop changed, too, from 0 to $87^{\circ}$ which was tested by the photograph of one minute after a water drop contact. It means the carburized calcine clay does not absorb water drop so it has a hydrophobic characteristic.

반송 시 웨이퍼 이탈을 최소화 하기 위한 새로운 형태의 웨이퍼 가이드 메커니즘 (New Mechanism for Wafer Guide to Minimize the Drop in Wafer Transfer)

  • 김대원;유지환
    • 반도체디스플레이기술학회지
    • /
    • 제9권1호
    • /
    • pp.23-28
    • /
    • 2010
  • In this paper, wafer drop from wafer guide mechanism, which is one of the serious problems in water transfer robot, is analyzed, and new wafer guide mechanisms are proposed to minimize this drop. Three types of new wafer guide mechanisms are proposed: roller type, gear type and L-shape rocker type. We choose one of the proposed mechanism, which is roller type, and verified this mechanism through real transfer experiment. Wafer picking up test is conducted with initial aligning error for simulating the wafer drop. Number of drop is compared between conventional mechanism and proposed mechanism. As a result, we can find the proposed mechanism can reduce the number of wafer drop dramatically.

소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(2) (Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry in Small Size Pipe (2))

  • 이동원;윤찬일;주문창
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.391-397
    • /
    • 2002
  • Pressure drop were experimentally investigated for ice slurry flowing in the acrylic pipes with inner diameter of 24 mm. Ice slurry was made from 6.5% ethylene glycol-water solution, and the pipes is consisted of horizontal, vertical (upward and downward) and $90^{\circ}$ elbow pipe. The ice Packing factor (IPF) and the flow rate of the experiments were varied from 0 to 30% and from 5 to 70kg/min respectively The measured pressure drop in various pipe positions were compared with those for the solution flow (IPF=0). The pressure drop was larder than that for solution flows as the IPF increased when the flow rate was low or very high. Sharp increases in pressure drop were observed for the cases when IPF is more than 70% in horizontal and vertical pipes, whereas the pressure drop increased with the IPF simultaneously in an elbow pipe.

용접식 판형 열교환기의 성능에 관한 실험적 연구 (Experimental study on the performance of a brazed plate heat exchanger)

  • 김종하;윤재호;권오경;김종훈;류해성;이창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

침심 노즐전극의 전기 유체역학적 액적 형성과정 (Electrohydrodynamic Drop Formation Processes of a Needle-Centered Nozzle Electrode)

  • 문재덕
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1807-1811
    • /
    • 2008
  • In this paper, the meniscus formation/deformation processes and conduction characteristics of the needle-centered ceramic nozzle electrode as an effective electrohydrodynamic (EHD) flow driving mechanisms for de-ionized water and silicone oil have been investigated. Results showed that the applied high voltage affected significantly on the processes, such as the drop formation mode, the deformation mode, the dripping mode, the jet mode, and the atomization mode. There was the EHD atomization mode for the de-ionized water while it was not occurred for the silicone oil, which, however, might be due to the lower electric conductivity and dielectric property of the oil than that of the water.

Gasket 방식 판형 열교환기의 고.저온부 유량 및 압력차에 따른 압력강하 특성 (Pressure Drop of a Gasket Sealed Plate Type Heat Exchanger upon its Operating Conditions)

  • 안준;김혁주;최규성;송대석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.189-194
    • /
    • 2009
  • In a gas engine based cogeneration system, heat is recovered from two parts, which are jacket water and exhaust gas. The heat from the jacket water is often recovered by a plate type heat exchanger and used for the room heating and/or hot water supply. Depending on the operating conditions of engine and heat recovery system, there should be imbalance in the flow rate and supply pressure between engine and heat recovery side of the heat exchanger. The imbalance cause the deformation of the plate, which affects the pressure drop characteristics. In the present study, the pressure drop inside the heat exchanger has been investigated in a 1/5 scaled test rig and compare with the experimental correlations, which are used for the design.

  • PDF