• Title/Summary/Keyword: Water Discharge

Search Result 3,348, Processing Time 0.068 seconds

Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin (낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석)

  • Lee, Hongshin;Son, Gontae;Gu, Jungeun;Konboonraksa T.;Lee, Hongtae;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

Property Conversion of Water and Removing Characteristics of Escherichia Coli Inner Discharge Tube With ZrO$_2$Beads (구형 ZrO$_2$를 충진한 방전관의 수질 변환 및 대장균제거 특성)

  • 이동훈;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.143-148
    • /
    • 2004
  • This paper shows property conversion of water and removing characteristics of Escherichia coli for discharge tube with $ZrO_2$ beads. At the result of the removal characteristic experiments of Escherichia coli using the discharge tube with $ZrO_2$ beads, because the electric field is also increased when input voltage is increased, the removal characteristic of Escherichia coli was appeared relation connection to input voltage. And if a passing number of test water in discharge tube with $ZrO_2$beads is increased, the removal ratio of Escherichia coli is to be increased because passing number of electric field section is increased. And if diameter of $ZrO_2$beads is increased, the removal time of Escherichia coli is to be decreased because dielectric polalization of $ZrO_2$beads. Also, the removal ratio of Escherichia coli of the discharge tube with $ZrO_2$beads. is appeared higher than the removal ratio of the discharge tube without $ZrO_2$beads. And a satulation punt of ozone and $H_2$ $O_2$generation density inner water was appeared near 60[min].

Removal characteristic of Escherichiacoli and water property conversion for Discharge tube with globular $ZrO_2$ (구형 지르코니아를 갖는 수방전관의 수질성분변환 및 세균제거특성)

  • Lee, Dong-Hoon;Park, Hong-Jae;Park, Jae-Youn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.550-553
    • /
    • 2003
  • This paper was shown water properly conversion and removal characteristic of escherichia coli for discharge tube with $ZrO_2$ beads. At the result of the removal characteristic experiments of escherichia coli using the discharge tube with $ZrO_2$ beads, because the electric field is also increased when input voltage is increased, the removal characteristic of escherichia coli was appeared relation connection to input voltage. And if a passing number of test water in discharge tube with $ZrO_2$ beads is increased, the removal ratio of escherichia coli is to be increased because passing number of electric field section is increased. And if diameter of $ZrO_2$ beads is increased, the removal time of escherichia coli is to be decreased because dielectric polalization of $ZrO_2$ beads. Also, the removal ratio of escherichia coli of the discharge tube with $ZrO_2$ beads. is appeared higher than the removal ratio of the discharge tube without $ZrO_2$ beads. And a salutation point of ozone and $H_2O_2$ generation density inner water was appeared near 60[min].

  • PDF

The Characteristics of High Ozone Concentration.Yield Multi-discharge Type Ozonizer for Water Environment Improvement (수질환경개선용 고농도·고수율 다중방전형 오존발생기의 특성)

  • ;宋炫直
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.203-203
    • /
    • 1999
  • In this paper, high concentration·yield multi-discharge type ozonizer( MDO ) of new discharge type using superposed silent discharge was designed and manufactured. MDO can be consisted with 3 kind of superposed silent discharge type ozonizer( SDO ) in accordance with power supply method that supplying power, which has 180[°] phase difference, to 3 electrodes and double gap. At the moment discharge characteristics and ozone generation characteristics of each SDO were investigated in accordance with quantify of supplied gas, the number of SDO, and the shapes of each SDO. In result ozone generation characteristics of 17185[ppm] and 783[g/kWh] were obtained, and whorl ozone of 17185[ppm] was in contact with dyeing water waste decolonization characteristics was excellent, so it confirmed that MDO could be used as water environment improvement facility.

Hydrogen Generation by Electrical Discharge through Metal/Water System

  • G. J. Kang;S. Y. Cha;Lee, W. M.;Park, Y. M.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.111-114
    • /
    • 1996
  • Hydrogen generation by dissociation of water is described. The major force for the dissociation comes from the oxidation potential of the reactive metal reacting with water whereas the minor role is played by electrical discharge which helps sustain the reaction. A premixed reactive metal/water system undergoes a fast hydrogen generation upon the ignition by an electrical pulse. In another method the reactive metal can be fed into the discharge. Some characteristics of the methods are discussed.

  • PDF

Study on Estimation and Application of Discharge Coefficient about Nonpoint Source Pollutants using Watershed Model (유역모형을 이용한 유량조건별 배출계수 산정 및 활용방안 연구)

  • Hwang, Ha-Sun;Rhee, Han-Pil;Park, Jihyung;Kim, Yong-Seok;Lee, Sung-Jun;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.653-664
    • /
    • 2015
  • TPLMS (Total water pollutant load management system) that is the most powerful water-quality protection program have been implemented since 2004. In the implementation of TPLMS, target water-quality and permissible discharged load from each unit watershed can be decided by water-quality modeling. And NPS (Non-point sources) discharge coefficients associated with certain (standard) flow are used on estimation of input data for model. National Institute of Environmental Research (NIER) recommend NPS discharge coefficients as 0.15 (Q275) and 0.50 (Q185) in common for whole watershed in Korea. But, uniform coefficient is difficult to reflect various NPS characteristics of individual watershed. Monthly NPS discharge coefficients were predicted and estimated using surface flow and water-quality from HSPF watershed model in this study. Those coefficients were plotted in flow duration curve of study area (Palger stream and Geumho C watershed) with monthly average flow. Linear regression analysis was performed about NPS discharge coefficients of BOD, T-N and T-P associated with flow, and R2 of regression were distributed in 0.893~0.930 (Palger stream) and 0.939~0.959 (Geumho C). NPS Discharge coefficient through regression can be estimated flexibly according to flow, and be considered characteristics of watershed with watershed model.

Development of a new system for measurement of total effluent load of water quality

  • Keiji, Takase;Akira, Ogura
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.221-221
    • /
    • 2015
  • Sustainable use of water resource and conservation of water quality are essential problems in the world. Especially, problems of water quality are serious one for human health as well as ecological system of all creatures on the earth. Recently, the importance of total effluent load as well as the concentrations of pollutant materials has been recognized not only for the conservation of water quality but also for sustainable water use in watersheds. However, the measurement or estimation of total effluent load from non-point source area such as farm lands or forests may be more difficult because both of concentration and discharge of the water are greatly changed depending on various factors especially metrological conditions such as rainfall, while the measurement from a point source area may be easy because the concentration of pollutant materials and amount of discharge water are relatively steady. Therefore, the total effluent load from a non-point source is often estimated by statistical relationships between concentration and discharge, which is called as L-Q equation. However, a lot of work and time are required to collect and analyze water samples and to get the accurate relationship or regressive equation. So, we proposed a new system for direct measurement of total effluent load of water quality from non-point source areas to solve the problem. In this system, the overflow depth at a hydraulic weir is measured with a pressure gage every hourly interval to calculate the amount of hourly discharge at first. Then, the operating time of a small electric pump to collect an amount of water which is proportional to the discharge is calculated to intake the water into a storage tank. The stored water is taken out a few days later in a case of storm event or several weeks later in a case of non-rainfall event and the concentrations of water quality such as total nitrogen and phosphorous are analyzed in a laboratory. Finally, total load of the water quality can be calculated by multiplying the concentration by the total volume of discharge. The system was installed in a small experimental forestry watershed to check the performance and know the total load of water quality from the forest. It was found that the system to collect a proportional amount of water to actual discharge operated perfectly and a total load of water quality was analyzed accurately. As the result, it was expected that the system will be very available to know the total load from a non-point source area.

  • PDF

Study on the Analysis of Development of Stage-Discharge Curve for Han River and Correlation between Items of Water Pollutants- Focused on Byeokgyeo Stream - (한강수계 유량곡선식 개발 및 수질오염물질 항목간 상관성 분석에 관한 연구- 벽계천 중심으로 -)

  • Hong, Sung-Ho;Ban, Jong-Seok;Jun, Hang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.394-400
    • /
    • 2012
  • We drew the stage-discharge relations of Byeokgye Stream, located in Yangpyeong-gun, Gyeonggi-do, and analysed the correlation between items of water pollutants by measuring the flow rate and water pollutants thirty-four times from April 2010 to December 2010. The results showed that it tended to be low water season from April to June and from October and December, while tending to be water season from July to September. The average flow rate was $2.137\;m^3/sec:\;0.464\;m^3/sec$ in low water season and $13.970\;m^3/sec$ in high water season. The stage-discharge curve thereon was $Q=40.107{\times}(h-1.200)^{2.877}$. As to the correlations, the correlation between the water temperature and COD was 0.58, and the correlations of SS with BOD and COD were 0.46 and 0.40 respectively. The correlation between SS and T-P was 0.73, showing higher than other items.

Limnological Characteristics of the River-type Paltang Reservoir, Korea: Hydrological and Environmental Factors (하천형 저수지 팔당호의 육수학적 특성:수문과 수환경 요인)

  • Shin, Jae-Ki;Kang, Chang-Keun;Kim, Ho-Sub;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.242-256
    • /
    • 2003
  • This study aimed to determine the relationship between rainfall-discharge patterns and maior aquatic environmental factors in a river-type reservoir. Specifically, daily monitoring was conducted in Paltang Reservoir from January 1999 to December 2001. Observation of the daily changes of the environment factors showed that natural meteorological factors and hydrological factors causing the change of water discharge had a major effect on the aquatic environment. Rainfall was the main source of hydrological changes, with its frequency a possible direct variable governing the range of discharge changes. Rainfall was weak in November${\sim}$May and heavy in June${\sim}$October (heavist in summer). The range of water discharge was greatest during summer (July to September) and lowest during winter (January to February). A principal component analysis (PCA) showed that aquatic environmental factors could be classified into three different types in the pattern of annual variation. First, type I included water temperature, turbidity, water color and organic matter (COD), which increased with increasing water discharge. Second, type ll consisted of DO and pH, which decreased with increasing water discharge. Third, type III included conductivity, alkalinity and chloride ion, which showed middle values with increasing water discharge. Monthly variation of aquatic environments explained by the first two dimensions of the PCA suggests that aquatic environments of Paltang Reservoir may have annual cycle typical of river-type reservoirs depending on hydrological factor such as water discharge.

The Characteristic of Hydrogen Generation on the Structure of Plasma Reactor Using the Streamer Discharge in the Water (수중 스트리머 방전용 플라즈마 반응기 구조에서 수소발생 특성)

  • Park, Jae-Youn;Kim, Jong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.37-42
    • /
    • 2006
  • The effect of arc like streamer discharge is investigated on the hydrogen generation using the multineedle-plate electrode geometry plasma realtor(MPER) and the needle-plate electrode geometry plasma reactor(NPER). In order to restrict waves at the water surface when the high voltage applied, two kinds of the insulator such as the rectangular mesh or the hole mesh type are installed under the water surface. The discharge assistant of the two type(the saw type and the $TiO_2$ pellet type) was placed under the water surface to investigate the effect of the water surface conditions. The experimental results are compared in case of the reactor with and without the discharge assistant on the water surface.