• Title/Summary/Keyword: Water Cycle Ratio

Search Result 224, Processing Time 0.022 seconds

Assessment of Flooding Vulnerability Based on GIS in Urban Area - Focused on Changwon City - (GIS 기반의 도시지역 침수 취약성 평가 - 창원시를 대상으로 -)

  • Song, Bong-Geun;Lee, Taek-Soon;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.129-143
    • /
    • 2014
  • The purpose of this study is to evaluate flooding vulnerability considering spatial characteristics focused on Changwon-si, Gyeongsangnam-do. Assessment Factors are water cycle area ratio, surface runoff, and precipitation. And construction of assessment factors and vulnerability was analyzed by GIS program. Water cycle ratio and surface runoff were vulnerable in urban area. Precipitation was often distributed in agriculture of the northern region. Results of flooding vulnerability were low in agriculture and forest of the northern region. In contrast, urban area was high because there has covered impervious land cover. Analytical results of flooding vulnerability density using hotspot spatial cluster analysis were high in urban area. And these areas were situated in down stream so flooding were generated. Therefore, flooding vulnerability assessment of this study can help for selecting construction sites of pervious land cover and rainwater management facilities in urban and environmental planning.

Comparative Exergy Analysis of Kalina and Organic Rankine Cycles for Conversion of Low-Grade Heat Source (저등급 열원의 변환을 위한 칼리나 사이클과 유기 랭킨 사이클의 엑서지 성능의 비교 해석)

  • KIM, KYOUNG HOON;JUNG, YOUNG GUAN;KO, HYUNG JONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.1
    • /
    • pp.105-111
    • /
    • 2020
  • The organic Rankine cycle (ORC) and the Kalina cycle system (KCS) are being considered as the most feasible and promising ways to recover the low-grade finite heat sources. This paper presents a comparative exergetical performance analysis for ORC and Kalina cycle using ammonia-water mixture as the working fluid for the recovery of low-grade heat. Effects of the system parameters such as working fluid selection, turbine inlet pressure, and mass fraction of ammonia on the exergetical performance are parametrically investigated. KCS gives lower lower exergy destruction ratio at evaporator and higher second-law efficiency than ORC. The maximum exergy efficiency of ORC is higher than KCS.

The Effect of Tidal Cycle and River Runoff on the Dynamic of Nutrients in Keum river estuary (금강하구역에서 영양염 거동에 대한 조석 및 담수유출의 영향)

  • Kim, Jong-Gu;Kang, Hoon
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.519-528
    • /
    • 2002
  • This study was to evaluate the impact of river runoff and salt intrusion by tide on nutrient balance of estuary during a complete tidal cycle. 24 hours time series survey was carried out during a spring tide July 2001 on a tidal estuary in the Keum river. Three stations(A,B,C) were set along a transect line of about 10km, which linked the lower part of estuary dyke to the subtidal zone. Surface water was sampled simultaneously at each station every hours f3r the determination of nutrients. Water temperature, pH and dissolved oxygen were measured in situ. Riverine input of silicate and nitrate during ebb tide significantly increased the concentration of all stations. Conversely, during high tide, nutrient concentration were lowered by the mixing of fresh water with sea water Ammonium nitrogen concentration were higher at intertidal zone(Stn.B) due to sewage inflow to Kyeongpo stream and ammonium release under anaerobic conditions. Also, these results was discussed as a biological component that influences the processes of nutrient regeneration within the estuary. Best correlations were found at lower part of estuary dyke(Stn.A) for salinity against DIN(Y=0.121 Sal.+4.97, r2=0.956) and silicate(Y=0.040 Sal.+2.62, r2=0.785). But no significant correlation was found between salinity and ammonium. Unbalanced elemental ratio(N/P, Si/N and Si/P) depended significantly on the import of nutrients (silicate & nitrate nitrogen) from river and stream. The effect of the tidal cycle and river runoff is important that in determining the extend of the variations in nutrient concentrations at all station.

Analysis of Hydrologic Cycle and BOD Loads Using HSPF in the Anyancheon Watershed (HSPF 모형을 이용한 안양천 유역의 물순환 및 BOD 부하량 분석)

  • Lee, Kil-Seong;Chung, Eun-Sung;Lee, Joon-Seok;Hong, Won-Pyo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.8
    • /
    • pp.585-600
    • /
    • 2007
  • The hydrologic cycle and BOD pollutant loads of all sub-watersheds were analyzed using HSPF (Hydrological Simulation Program-Fortran). At first, sensitivity analyses to water quantity (peak discharge and total volume) and quality (BOD peak concentrations and total loads) were conducted and some critical Parameters were selected. For more precise simulation, the study watershed was divided into four parts according to the landuse characteristics and used climate data and so calibrated and verified respectively. It was found that as the urban area ratio increases in the downstream direction, baseflow decreases (11.1 % $\rightarrow$ 5.0%) and the ratio of direct runoff volume(42.5 % $\rightarrow$ 56.9 %), BOD concentration (3.3 mg/L $\rightarrow$ 15.0 mg/L) and unit loads (55.4 kg/ha/year $\rightarrow$ 354.5 kg/ha/year) increase.

Exergy Analysis of Regenerative Gas Turbine Systems with Afterfogging (압축기 출구 물분사가 있는 재생 가스터빈 시스템의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • An exergy analysis is carried out for the regenerative gas turbine cycle which has a potential of enhanced thermal efficiency and specific power owing to the more possible water injection than that of inlet fogging under the ambient conditions. Using the analysis model in the view of the second law of thermodynamics, the effects of pressure ratio, water injection ratio and ambient temperature are investigated on the performance of the system such as exergetic efficiency, heat recovery ratio of recuperator, exergy destruction or loss ratios, and on the optimal conditions for maximum exergy efficiency. The results of computation for the typical cases show that the regenerative gas turbine system with afterfogging can make a notable enhancement of exergy efficiency.

  • PDF

Hydrogen Prodution by Sulfur Thermochemical Water Splitting Cycle: Part 1. H2O-SO2-I2 Reaction and Separation (황 - 요오드의 열화학적 물분리에 의한 수소제조연구 Part I. 물-이산화황-요오드 반응 및 분리)

  • Lee, K.I.;Min, B.T.;Kwon, S.G.;Kang, Y.H.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.1 no.1
    • /
    • pp.40-47
    • /
    • 1989
  • The sulfur-iodine thermochemical water splitting process of GA(General atomic) cycle was studied to produce hydrogen from water by $H_2-I_2-SO_2$ reactions. The experimental scale was 500g based on iodine. The reaction took 100 minutes, products could be separated two liquid phases due to their density difference:HI solution had a density of 2.39~2.61g/cc, and $H_2SO_4$ solution had 1.37~1.38g/cc. The condition of reaction was when weight ratio of $I_2/H_2O$ was 2/1 resulting in good phase separation and productivity.

  • PDF

Thermodynamic Analysis of Thermochemical Process for Water Splitting (고온열 이용 공정의 열역학적 해석)

  • Kim, Jong-Won;Son, Hyun-Myung;Lee, Sana-Ho;Sim, Kyu-Sung;Jung, Kwang-Deog
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.3
    • /
    • pp.204-213
    • /
    • 2002
  • In this work, hydrogen production by a 2-step water-spritting thermochemical cycle based on metal oxides redox pairs was investigated on the bases of the thermodynamics and technical feasibility. Also, a 2nd-law analysis performed on the closed cyclic process indicates a maximum exergy conversion efficiency of 7.1% when using a solar cavity-receiver operated at 2300K and air/Fe3O4 molar ratio = 10.

Performance Analysis of a Wet Air-Cycle Refrigeration System (습공기사이클 냉동시스템의 성능해석)

  • Won, Sung Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

Analysis on Water Retention Rate according to Water Cycle Characteristics in Jeju Gotjawal Forest (제주 곶자왈 산림의 물순환 특성에 따른 수원함양률 분석)

  • Jaehoon Kim;Honggeun Lim;Hyung Tae Choi;Qiwen Li;Haewon Moon;Hyungsoon Choi
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1013-1025
    • /
    • 2022
  • This study was carried out to analyze water cycle characteristics and evaluate water retention function in Jeju Gotjawal forest from 2013 to 2017. The average ratio of throughfall, stemflow, interception loss in Seonhul Gotjawal (SH) and Cheongsu Gotjawal (CS) was 43.1%, 15.8%, and 41.1%, respectively. Rainfall-throughfall, rainfall-stemflow, and rainfall-interception loss were expressed as linear regression equation (p<0.001). The comparison results showed that SH was higher than CS (p<0.05), indicating that the canopy area had an important effect on the difference in stand structure. The average water resources retention rate of the Gotjawal region was 41.9%, which is similar to the total water resources retention rate (40.6%) of Jeju Special Self-Governing Province (JSSGP). Currently, the development of Gotjawal is in progress in JSSGP. The development of Gotjawal will lead to a decrease in the water resources retention rate due to changes in the surface environment such as an increase in impervious areas, which will affect the total groundwater content of JSSGP. Therefore, the conservation of the Gotjawal area is judged to be very important from the point of view of water conservation.

Study on the optimum operation system of Sequencing Batch Reactor (연속 회분식 반응조의 최적 운전시스템에 관한 연구)

  • Eom, Tae Kyu;Ko, Eun Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.54-61
    • /
    • 1999
  • SBR process used to evaluate the removal of organics, nitrogen and phosphorus on the basis of a report of research on a precedence at various operation cycle and condition change. Effluent concentration of COD were 50mg/l, 50mg/l, 90mg/l respectively, The removal rates of COD were nearly over 95% at Run 1, 2 and 4. But at Run 3, Effluent concentration of COD was 255.0mg/l, The removal rate of COD was 87% at Run 3. As Oxic/Anoxic rate was fixed and operating cycle of Oxic/Anoxic was changed, the removal rates of T-N were 74.7%, 46.9%, 28.5%, 63.3% respectively at Run 1~4. The case of Run 1 was best result. The removal rates of T-P was appeared in proportion to T-N removal rates and rest of $NO_2-N$. The removal rates of T-P were 51.2%, 35.5%, 41.5%, 51.9% respectively. The removal rates of COD, T-N, T-P were influenced on the change of SBR operation cycle. As organic loading rate was $1.43kgCOD/m^3day$ and C/N ratio was 3.0, operation cycle of Run 1 was best condition of T-N removal rates and T-P removal.

  • PDF