• Title/Summary/Keyword: Water Contamination

Search Result 1,552, Processing Time 0.027 seconds

A study of the pollution of ground water in the basin of the river Baem Nae Chun, Sorae-Myun, Shihoong-gon, Kyonggi-Do, Korea (경기도 시흥군 소래면 뱀내하천 유역의 지하수 오염에 관한 연구)

  • 김윤종;정봉일
    • Water for future
    • /
    • v.6 no.2
    • /
    • pp.19-29
    • /
    • 1973
  • The progressive contamination of water resulted from man's activity and the use of fertilizers is not restricted only to surface water, but also the shallow groundwater is affected. This type of groundwater contamination is mainly restricted to areas composed of permeable, nonconsolidated sediments forming a shallow aquifer. The chloride and the sulfate resulted from man's activity and the use of fertilizers were measured to study the variations of the groundwater contamination. In general, (1) When water level rises, the rate of groundwater contamination becomes less and when water level declines, the rate of contamination is increased. (2) The highly contaminated season is the early-summer and the less contaminated season is the winter or after rainy season. (3) The groundwater in weathering zone without covering layer. (4) The degree of contamination of wells is increased with the increase of well depth and lowing the water table, because of increasing contaminated water from enlargement of the area of influence of the well.

  • PDF

A Study on the Drinking Water Quality and Contamination Sources in a Rural Area (일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

Reducing Fetal Contamination of Radiostronium by Water Soluble Chitosan

  • Kim, Young-Ho;Roh, Young-Bok;Kim, Kwang-Yoon;Bom, Hee-Seung;Kim, Jl-Yeul
    • Animal cells and systems
    • /
    • v.1 no.2
    • /
    • pp.337-340
    • /
    • 1997
  • The purpose of this study is to evaluate whether water soluble chitosan, a natural nontoxic chelator, can reduce fetal contamination of radiostrontium in pregnant mice. Various forms of water soluble chitosans (10% or 1% powder, or 1% solution) were given to pregnant mice before or after contamination of 0.005 uCi/B.W(g) Sr-85. Transplacental transfer of Sr-85 to fetus was $6.8{\pm}2.7%$ of injected dose, when Sr-85 was administered at the 20th day of pregnancy. Fetal radioactivity was significantly reduced when mother mice were treated with water soluble chitosan before contamination of Sr-85. Water soluble chitosans of 10% or 1% powder, or 1% solution significantly reduced fetal retention of Sr-85 to $2.3{\pm}0.7%$, $2.7{\pm}0.8%$, and $2.0{\pm}0.9%$, respectively. However, fetal contamination was not reduced, when water soluble chitosans of 10% or 1% powder, or 1% solution were administered after maternal contamination of Sr-85. From these data we can conclude that water soluble chitosan could reduce fetal contamination of radiostrontium in pregnant mice, when given before the pregnant mice were exposed to radiostrontium.

  • PDF

Technical Approaches for Assessment of Ground Water Contamination with TCE in an Industrial Area

  • Jeon, Kweonho;Yu, Soonyoung;Jeong, Jangsik;Son, Yanglae
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.10a
    • /
    • pp.70-86
    • /
    • 2003
  • Despite its usability, TCE has been managed as a hazardous material due to the toxicity and many contamination cases were surveyed in some developed countries. U.S.EPA(Kram et al., 2001) suggested DNAPL characterization methods and approaches based on survey experiences at several sites. However, Korea has not the least assessment of contamination and trial of remediation, although there are a lot of doubtable areas where ground water would be contaminated with TCE. In this study, we try to assess the volume and extent of ground water contamination with TCE and delineate the contamination source zones in an industrial area. Ground water in this area flows through fractures and the contaminant TCE has the properties of high volatility, high density and low partitioning to soil material. Thus, we applied a variety of technical approaches to identify the contamination status; documentary, hydrogeochemical, hydrogeological and geological surveys. In addition, additional survey was performed based on the interim findings, which showed that ground water contamination was limited to the relatively small area with high concentrations to the deep place. The contamination source zone is estimated to be the asphalt test institute where a great deal of TCE has been used to analyze the amount of asphalt soluble in TCE since 1984. Based on the contamination characterization and a myriad of documents about ground water remediation, appropriate site remediation management options will be recommended later. This study is now under way and this paper was focused on describing the technical approaches used to achieve the goals of this study.

  • PDF

A study on Investigation of Fecal Contamination Indicator Bacteria for Management of Source Water Quality (상수원 수질관리를 위한 분변오염 지표세균에 관한 연구)

  • 장현정;이용욱
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • Coliforms is currently being used as the standard of environmental water qualify to evaluate the level of source water quality especially condition of fecal contamination. However, not properly applied to water quality management. So in this study, in addition to Coliforms, fecal contamination indicator bacteria turk at Feral Coliforms(FC), E. coli, Fecal streptococci(FS), Clostridium and environmental parameters related with it's distribution were investigated on a monthly basis in 6 water intakes of Han River. The mean of BOD, DO, SS and pH, benchmarks of source water management were maintained the second grade of environmental water quality standard applied to Han River but Coliforms exceeded it. Distribution of Coliforms ranged from 1.0×10¹ to 2.7 10/sup 5/ CFU/ml, FC ranged from ND to 5.3×10¹ CFU/ml, E. coli ranged from ND to 9.2×10¹ CFU/ml, FS ranged from ND to 2.5×10¹CFU/ml, they were steepy rise on July and August in common when rainfalls was heavy and water temperature was high, but Clostridium perfringens ranged from 1.7×10¹to 1.7×10¹CFU/ml not fluctuate by month. Statistical analysis of sampling data showed that most significant correlations occurred among FC and Coliforms(r = 0.840), E. coli(r = 0.792), FS(r = 0.687) and environmental parameters(temperature, turbidity, SS, rotor were all r > 0.60) while no significant correlation was observed between ammonia generally recognized fecal contamination indicator and bacteria. Identification of the coliforms showed that Enterobacter, Klebsiella, Citrobacter were comprised of 32%, 24%, 16% respectively, and E. coli were 7% of it. while E. coli was made up 85.9% of FC. The mean value of FC/Coliforms ratio, 5.2(0.1-42) were higher in Amsa, Guui than Jayang. Fecal coliforms, as those are able to reflect more particularly the extent of the fecal contamination, were considered useful in deciding the level of water treatment while monitoring the fecal contamination from the source of water supply. Therefore, it is expected that the water quality is going to be managed more efficiently by using fecal coliforms supplementarily to total coliforms which are current standard item of water-quality environment.

Characteristics of Groundwater Contamination in Uncontrolled Landfill and Pollution Control Measures (불량 매립지에서의 지하수 오염특성과 환경오염 방지방안)

  • 구자중;윤석표
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.05a
    • /
    • pp.28-44
    • /
    • 1993
  • Remediation actions in uncontrolled landfill site should be conducted after the investigation of contamination status and potential health risk or damage. Based on the above, proper control measures should be established and operated. Also continuous monitoring should be followed. In this study, the status of ground water contamination around Nanji Landfill Site was investigated. Monitoring wells were installed around the landfill and ground water was sampled once a month and analyzed. Water quality of each monitoring well was different depending on the horizontal and vertical distance from the landfill, and the seasonal leachate characteristics were not significantly changed because percolating water stayed long time in the deep waste layer. It was predicted that major multivalent cations were mainly precipitated as metal carbonate form, and chemical mass balances (CMBs) could be applied for the apportionment of leachate contamination to ground water quality of surrounding areas of Nanji Landfill. Parameters required to estimate pollutant flux to the receptor near landfill were listed and discussion to get these parameters was made. Finally, based on the above data, control measures of ground water contamination were suggested and discussed.

  • PDF

Study on the Drinking Water Index with Minerals and Anions (식수의 수질중 미네랄성분과 음이온을 이용한 지수에 관한 연구)

  • 김형석;신현덕;이기태
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.99-108
    • /
    • 1993
  • It is well known that we should take 2L of drinking water per day to maintain our health. The drinking water quality is becoming worse owing to sewage discharge and industrial wastewater. Surface water is polluted by various kinds of contaminants and ground water were known as clean and unpolluted water, but through recent many reports the ground waters are also contaminated by waste disposal and intrusion of organic and bacterial movement. This research was undertaken to make a water index of water contamination by referringcations cations and anions. NH$_{4}$, Fe, Mn, and Pb are chosen as cations and $NO_3$, Cl, and $SO_4$ ions are chosen as anions to make a index, and the following water index was made as the contamination index. (Fe+Mn+Pb)/0.7+$(NH_4+NO_3+Cl+SO_4)$/10.5<6.0 By using ton Chromatography the cations and anions are rapidly analyzed and plotting the analyzed data to the equation, we can easily get the degree of contaminations by avoiding analysis of over 37 water parameters in several days. Of course this index of water contamination is not perfect and detail one, but in case of emergent case or to know the overall trends of contamination, it is convenient to use this index. Among the tested 5 kinds of samples the ground water showed contamination index of 6.87. Authors used the already published healthy index and tasty index and differentiated their degrees in detail.

  • PDF

The role of domestic tap water in Acanthamoeba contamination in contact lens storage cases in Korea

  • JEONG Hae Jin;YU Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.2 s.134
    • /
    • pp.47-50
    • /
    • 2005
  • A survey was carried out from August to December 2004 in Pusan, Korea to document the presence of free-living amoeba (FLA), including the genus Acanthamoeba, in both contact lens storage cases and domestic tap water. Acanthamoeba was isolated from $5(4.2\%)$ in 120 contact lens storage cases. Four house tap water samples from residents, whose contact lens storage cases had been contaminated by Acanthamoeba, were also found to be contaminated with Acanthamoeba. Therefore, the contamination rate of FLA and Acanthamoeba in domestic tap water was investigated in order to examine the role of domestic tap water in Acanthamoeba contamination of contact lens storage cases. FLA and Acanthamoeba were identified in $97(46.8\%)\;and\;16(7.7\%)$ of the 207 domestic tap water samples, respectively. There were no significant differences between the contamination rates of FLA in tap water according to the filtration plant of origin. No FLA was detected in the tap water directly supplied by the water purification plants. Water storage tanks appear to promote FLA colonization, including Acanthamoeba, in domestic tap water. This increases the risk of Acanthamoeba contamination in contact lens storage cases as well as increasing the risk of Acanthamoeba keratitis.

Remote Sur-veillance network system for water contamination using Sensor network (센서 네트워크를 이용한 수질 감시 원격 시스템)

  • Kak, Ho-Hjub;Park, Se-Hyun;Park, Se-Hun;Kim, Eung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.865-868
    • /
    • 2008
  • Remote Sur-veillance network system for water contamination is developed using sensor network. The wireless sensor network is one of effective solutions for monitoring water contamination on wide area such s river. Existing sur-veillance system for water contamination has the disadvantage in installation cost, complexity of adding a new node replacing a defective node. The proposed system has cost effective solutions compared with the existing system.

  • PDF

Establishment of Landfill Site Preliminary Assessment Model Based on Contamination Characteristics of Water Resources (수자원(水資源) 오염 특성에 의한 불량매립지(不良埋立地) 예비평가모형(豫備評價模型) 정립)

  • Hong, Sang-Pyo;Kim, Jung-Wuk
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 1995
  • To assess preliminarily the contamination potential of water resources including groundwater owing to the hydrogeological characteristics of landfill site and the potential impact to humans and animals through contamination of water resources by leachate, "Landfill Site Preliminary Assessment Model(LASPAS)" was contrived. LASPAS could help them proritization of remediation of landfil sites by the convenient and relatively simple evaluation method of landfill site features. LASPAS was designd to aliot numerical ratings to landfill site related factors undermentioned; 1) hydrogeological factors such as hydraulic conductivity of aquifer, thickness of confining layer over aquifer, topographical slope, net recharge, and subsurface containment 2) water resources contamination factors of impacts on receptors such as proximity to drinking water supply, substitutability of drinking water supply, type of use of water resources, known impact on drinking water supply, and flood potential.

  • PDF