Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

Modeling of temperature history in the hardening of ultra-high-performance concrete

  • Wang, Xiao-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.3
    • /
    • pp.273-284
    • /
    • 2014
  • Ultra-high-performance concrete (UHPC) consists of cement, silica fume (SF), sand, fibers, water and superplasticizer. Typical water/binder ratios are 0.15 to 0.20 with 20 to 30% silica fume. In the production of ultra-high performance concrete, a significant temperature rise at an early age can be observed because of the higher cement content per unit mass of concrete. In this paper, by considering the production of calcium hydroxide in cement hydration and its consumption in the pozzolanic reaction, a numerical model is proposed to simulate the hydration of ultra-high performance concrete. The heat evolution rate of UHPC is determined from the contributions of cement hydration and the pozzolanic reaction. Furthermore, by combining a blended-cement hydration model with the finite-element method, the temperature history in the hardening of UHPC is evaluated using the degree of hydration of the cement and the silica fume. The predicted temperature-history curves were compared with experimental data, and a good correlation was found.

Energy Performance and Cost Assessment for Implementing GroundSource Heat Pump System in Military Building (군사시설 내 지열 히트펌프 시스템 적용에 따른 에너지 성능과 비용 절감 효과 평가)

  • Byonghu Sohn;Kyung Joo Cho;Dong Woo Cho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.45-57
    • /
    • 2022
  • The Ministry of National Defense of the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of military facilities and to promote green growth policy in military sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. This paper analyzed energy performance and energy cost on the conventional heating and cooling system (baseline scenario) and three different alternative scenarios (ALT 1, ALT 2 and ALT 3) applied in a hypothetical military building. A building modeling and simulation software (DesignBuilder V6.1) with EnergyPlus calculation engine was used to calculate the energy consumption for each scenario. Overall, when the GSHPs are applied to both space airconditioning and domestic hot water (DHW) production, Alt-2 and Alt-3, the amount of energy consumption for target building can be greatly reduced. In addition, when the building envelope performance is increased like Alt-3, the energy consumption can be further reduced. The annual energy cost analysis showed that the baseline was approximately 161 million KRW, while Alt-3 was approximately 33 million KRW. Therefore, it was analyzed that the initial construction cost increase could be recovered within about 6.7 years for ALT 3. The results of this study can help decision-makers to determine the optimal strategy for implementing GSHP systems in military buildings through energy performance and initial construction cost assessment.

Estimation and evaluation of irrigation water need using net water consumption concept in Jeju Island (순물소모량 개념에 의한 제주도 농업용수 수요량 산정 및 평가)

  • Kim, Chul Gyum;Kim, Nam Won
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.503-511
    • /
    • 2017
  • In order to estimate the demand for water resources planning and operation, methodology for determining the size of water supply facilities has been mainly applied to agricultural water, unlike living and industrial water, which reflects actual usage trends. This inevitably leads to an overestimation of agricultural water and can lead to an imbalance in the supply and demand of each use in terms of the total water resources plan. In this study, the difference of approaches of concept of net consumption was examined in comparison with the existing methodology and the characteristics of agricultural water demand were analyzed by applying it to whole Jeju Island. SWAT model was applied to estimate the amount of evapotranspiration, which is a key factor in estimating demand, and watershed modeling was performed to reflect geographical features, weather, runoff and water use characteristics of Jeju Island. For the past period (1992~2013), demand of Jeju Island as a whole was analyzed as 427 mm per year, and it showed a relatively high demand around the eastern and western coastal regions. Annual demand and seasonal variation characteristics of 10 river basins with watershed area of $30km^2$ or more were also analyzed. In addition, by applying the cultivated area of each crop in 2020 in the future, it is estimated that the demand corresponding to the 10-year frequency drought is 54% of the amount demanded in the previous research. This is due to the difference in approach depending on the purpose of the demand calculation. From the viewpoint of water resource management and operation, additional demand is expected as much as the net consumption. However, from the actual supply perspective, it can be judged that a facility plan that meets the existing demand amount is necessary. In order to utilize the methodologies and results presented in this study in practice, it is necessary to make a reasonable discussion in terms of policy and institutional as well as engineering verification.

System Response of Automotive PEMFC with Dynamic Modeling under Load Change (차량용 PEMFC 동적 모델을 이용한 시스템 부하 응답 특성)

  • Han, Jaeyoung;Kim, Sungsoo;Yu, Sangseok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.43-50
    • /
    • 2013
  • The stringent emission regulation and future shortage of fossil fuel motivate the research of alternative powertrain. In this study, a system of proton exchange membrane fuel cell has been modeled to analyze the performance of the fuel cell system for automotive application. The model is composed of the fuel cell stack, air compressor, humidifier, and intercooler, and hydrogen supply which are implemented by using the Matlab/Simulink(R). Fuel cell stack model is empirical model but the water transport model is included so that the system performance can be predicted over various humidity conditions. On the other hand, the model of air compressor is composed of motor, static air compressor, and some manifolds so that the motor dynamics and manifold dynamics can be investigated. Since the model is concentrated on the strategic operation of compressor to reduce the power consumption, other balance of components (BOP) are modeled to be static components. Since the air compressor model is empirical model which is based on curve fitting of experiments, the stack model is validated with the commercial software and the experiments. The dynamics of air compressor is investigated over unit change of system load. The results shows that the power consumption of air compressor is about 12% to 25% of stack gross power and dynamic response should be reduced to optimize the system operation.

Optimal Control Strategies for Energy Saving of Central Cooling System with Outdoor Air Temperature Changes (외기온도 변화특성을 고려한 중앙냉방시스템의 에너지 절감 최적제어에 관한 연구)

  • Park, Ki-Tae;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4260-4266
    • /
    • 2015
  • In this study, the optimal control method for minimizing of energy consumption for central cooling system with proper occupant comfort level is researched by simulation. The optimal control method is that the optimal set temperatures such as the condenser water temperature, supply air temperature, and chilled water temperature with environment variable change such as outdoor air dry-bulb and wet-bulb temperatures are obtained by suggested optimal control algorithm with maximum and part building load. The TRNSYS program is used for system modeling and the control performances with the suggested optimal control method are compared with the existing control method of fixed set points. The suggested optimal control method shows better responses in energy consumption in comparison with existing control ones.

A comparison between fuel cells and other alternatives for marine electric power generation

  • Welaya, Yousri M.A.;Gohary, M. Morsy El;Ammar, Nader R.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.2
    • /
    • pp.141-149
    • /
    • 2011
  • The world is facing a challenge in meeting its needs for energy. Global energy consumption in the last halfcentury has increased very rapidly and is expected to continue to grow over the next 50 years. However, it is expected to see significant differences between the last 50 years and the next. This paper aims at introducing a good solution to replace or work with conventional marine power plants. This includes the use of fuel cell power plant operated with hydrogen produced through water electrolysis or hydrogen produced from natural gas, gasoline, or diesel fuels through steam reforming processes to mitigate air pollution from ships.

Modeling of Dielectric Barrier Discharge Plasma Process for the Removal of Nitric Oxide (유전체 방전 플라즈마 공정에 의한 일산화질소 제거 공정 모델링)

  • Mok, Young-Sun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.277-289
    • /
    • 2003
  • This study proposes a mathematical model to characterize the removal of nitrogen oxides in a dielectric barrier discharge plasma process. As well as the reactions between nitrogen oxides, water vapor, oxygen and nitrogen, the model takes into account the effect of ethylene often used as a chemical additive to reduce the power consumption of the process on the removal of nitrogen oxides. Since the concentrations of the radicals concerned in the main reactions including O, OH, H and N should be calculated to predict the removal efficiency of nitrogen oxides, they were theoretically derived. The parameters affecting the removal of nitrogen oxides, such as initial concentration, discharge power, humidity, and ethylene concentration were experimentally evaluated, which were compared with the calculated results to verify the validity of the model proposed. The predicted concentrations of several byproducts formed in this process were also presented and discussed. The effects of several parameters mentioned above on the removal of nitrogen oxides were reasonable described by the proposed model.

  • PDF

CFD Simulation Tool for Anode-Supported Flat-Tube Solid Oxide Fuel Cell

  • Youssef M. Elsayed.;Lim, Tak-Hyoung;Song, Rak-Hyun;Lee, Seung-Bok;Shin, Dong-Ryul
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.4
    • /
    • pp.151-157
    • /
    • 2006
  • A two-dimensional numerical model to study the performance of anode-supported flat-tube solid oxide fuel cell (SOFC) far the cross section of the cell in the flow direction of the fuel and air flows is developed. In this model a mass and charge balance, Maxwell-Stefan equation as well as the momentum equation by using, Darcy's law are applied in differential form. The finite element method using FEMLAB commercial software is used for meshing, discritization and solving the system of coupled differential equations. The current density distribution and fuel consumption as well as water production are analyzed. Experimental data is used to verify a predicted voltage-current density and power density versus current density to judge on the model accuracy.

Estimation of the Exploitable Carrying Capacity in the Korean Water of the East China Sea (한국 남해의 어획대상 환경수용량 추정 연구)

  • ZHANG, Chang-Ik;SEO, Young-Il;KANG, Hee-Joong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.513-525
    • /
    • 2017
  • In the estimation of the exploitable carrying capacity (ECC) in the Korean water of the East China Sea, two approaches, which are the ecosystem modeling method (EMM) and the holistic production method (HPM), were applied. The EMM is accomplished by Ecopath with Ecosim model using a number of ecological data and fishery catch for each species group, which was categorized by a self-organizing mapping (SOM) based on eight biological characteristics of species. In this method, the converged value during the Ecosim simulation by setting the instantaneous rate of fishing mortality (F) as zero was estimated as the ECC of each group. The HPM is to use surplus production models for estimateing ECC. The ECC estimates were 4.6 and 5.1 million mt (mmt) from EMM and HPM, respectiverly. The estimate from the EMM has a considerable uncertainty due to the lack of confidence in input ecological parameters, especially production/biomass ratio (P/B) and consumption/biomass ratio (Q/B). However, ECC from the HPM was estimated on the basis of relatively fewer assumptions and long time-series fishery data as input, so the estimate from the HPM is regarded as more reasonable estimate of ECC, although the ECC estimate could be considerd as a preliminary one. The quality of input data should be improved for the future study of the ECC to obtain more reliable estimate.