• Title/Summary/Keyword: Water Concentration

Search Result 11,857, Processing Time 0.037 seconds

A study on the Measurement of Soil Water Concentration by Time Domain Reflectometry (TDR(Time Domain Reflectometry)을 이용한 토양수농도 측정에 관한 연구)

  • Park, Jae-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.123-132
    • /
    • 1998
  • Monitoring solute transport has been known to be difficult especially for the unsaturated soil. The object of this study is to investigate the TDR application to monitoring solute concentration in the vadose zone. The TDR calibration test was conducted for soil samples with various water contents and concentrations. The voltage attenuation of electromagnetic wave of TDR was used to estimate the bulk electrical conductivity of a soil. The relationship between the bulk soil electrical conductivity and the solute concentration was assumed to be linear at a constant volumetric soil water content. In this study four proposed relationships were compared using data obtained from KCI solution at three different concentrations. Relationships given by Topp, Daltaon, Yanuka showed the linearity between the bulk soil electrical conductivity and the solute concentration, which were more pronounced than Zegelin's. The three relationships were found to be useful to measure the solute concentration in the vadose zone. In addition, TDR method was proven to be a viable technique in monitoring solute transport through unsaturated soils in transient flow condition.

  • PDF

Phosphorus Budget of a River Reservoir, Paldang (하천형 호수인 팔당호의 인 수지)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.270-284
    • /
    • 2018
  • Paldang is a river reservoir located in the Midwest of Korea, with a water volume of $244{\cdot}10^6m^3$ and a water surface area of $36.5km^2$. It has eutrophied since the construction of a dam at the end of 1973, and the phosphorus concentration has decreased since 2001. Average hydraulic residence time of the Paldang reservoir is about 10 days during the spring season and 5.6 days as an annual level. The hydraulics and water quality of the reservoir can differ greatly, both temporally and spatially. For the spring period (March to May) in 2001 ~ 2017, the reservoir mean total phosphorus concentration calculated from the budget model based on a plug-flow system (PF) and a continuous stirred-tank reaction system (CSTR) was 13 % higher and 10 % lower than the observed concentration, respectively. A composite flow system (CF) was devised by assuming that the transition zone was plug flow, and that the lacustrine zone was completely mixed. The mean concentration calculated from the model based on CF was not skewed from the observed concentration, and showed just 6 % error. The retention coefficient of the phosphorus derived from the CF was 0.30, which was less than those of the natural lakes abroad or river reservoirs in Korea. The apparent settling velocity of total phosphorus was estimated to be $93m\;yr^{-1}$, which was 6 ~ 9 times higher than those of foreign natural lakes. Assuming CF, the critical load line for the total phosphorus concentration showed a hyperbolic relation to the hydraulic load in the Paldang reservoir. This is different from the previously known straight critical load line. The trophic state of the Paldang reservoir has recently been estimated to be mesotrophic based on the critical-load curve of the phosphorus budget model developed in this study. Although there is no theoretical error in the newly developed budget model, it is necessary to verify the validity of the portion below the inflection point of the critical-load curve afterwards.

Parameters Affecting Indoor Air Exposure to Volatile Organic Compounds (휘발성 유기화합물에 대한 실내공기노출에 영향을 미치는 인자)

  • ;C.P. Weisel
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1992
  • Volatile organic rompounds(VOCs) present in the VOCs-contaminated water are released to air while showering and their air concentrations depend on the shower parameters, resulting in the variation of the VOCs breath concentration. The present study evaluated the key shower parameters(water temperature and inhalation duration) that affect the inhalation exposure to air chloroform while showering, by determining chloroform breath concentration. The chloroform breath concentrations increased with water temperature and inhalation duration increase. The two inhalation exposure conditions which resulted in the greatest chloroform breath contentration difference were a 5 min-inhalation exposure with warm water and a 15 min-inhalation exposure with hot water. The chloroform breath concentration was almost three times higher after later exposure. The mathematical model analyzing the relationship between two key shower parameters and breath concentration normalized to water concentration fits quite Ivell with the experimental data at a probability of p : 0.0001.

  • PDF

High-Sensitivity Microstrip Patch Sensor Antenna for Detecting Concentration of Ethanol-Water Solution in Microliter Volume (마이크로리터 부피의 에탄올 수용액 농도 검출을 위한 고감도 마이크로스트립 패치 센서 안테나)

  • Junho Yeo;Jong-Ig Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.510-515
    • /
    • 2022
  • In this paper, a microstrip patch sensor antenna (MPSA) for detecting the concentration of an ethanol-water solution in a microliter volume is proposed. A rectangular slot was added at the radiating edge of the patch to increase the sensitivity to the relative permittivity change. To improve a low input resistance caused by placing an ethanol-water solution, which is a polar liquid with high dielectric constant and high loss tangent, on the patch, a quarter-wave impedance transformer was added between the 50-ohm feedline and the patch, and the MPSA was fabricated on a 0.76 mm-thick RF-35 substrate. A cylindrical container was made of acryl, and 15 microliters of the ethanol-water solution was tested from 0% to 100% of ethanol concentration at 20% intervals. Experiment results show that the resonant frequency increased from 1.947 GHz to 2.509 GHz when the ethanol concentration of the ethanol-water solution was increased from 0% to 100%, demonstrating the performance as a concentration detecting sensor.

Comparison of sampling method of phytoplankton for type approval of ballast water management system (선박평형수처리장치 형식승인을 위한 식물플랑크톤 샘플링 방법 비교)

  • Jang, Pung-Guk;Hyun, Bonggil;Lee, Woo-Jin;Choi, Keun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.426-433
    • /
    • 2020
  • This study aimed to compare the pretreatment methods of phytoplankton for type approval of the Ballast Water Treatment System (BWMS). The International Maritime Organization (IMO) and the United States Maritime Police (USCG) use two different test methods for this purpose. To compare the two methods, a test for concentration and non-concentration was performed with cultured and natural phytoplankton, and samples from the land-based BWMS test. The extent of damages caused by the process of concentration varied between cultured and natural species, indicating differences depending on the physiological and morphological characteristics of the species. In the land-based test, in the control water with a high biological population, the number of non-concentrated samples was about twice as high as that of the concentrated samples. There was no distinct difference between the two methods in the treated water with a low biological population. Thus, although there is a difference between concentration and non-concentration for phytoplankton sampling, the concentration method can be applied as a method of evaluating BWMS performance. However, a method for evaluating whether live species in treated water may be lost or damaged during the concentration process of sampling should be developed and validated.

A study on the Character of Water Quality according to the Flux in Pal-Dang Reservoir (팔당호 유량변동에 따른 수질특성에 관한 연구)

  • 김종민
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.12-24
    • /
    • 1995
  • I tried to evaluate the reason of the monthly variation of water quality according to the hydrologic character of Pal- dang reservoir inflow variation. The result of this study is as below; 1 ) COD, BOD, Total- nitrogen and Total- phosphate concentration increase generally according to the flux and Total- phosphate concentration is the most affected item by flux. 2) COD, BOD, Total- nitrogen and Total- phosphate concentration increase according the flux, but they begin to decrease at the below point ; COD · 1,154 CMS, BOD : 1,007 (CMS cubicmeter per second ) and Inflow- Concentration interrelation formula is as below; table omitted.

  • PDF

Effects of Water on the Electrical Conductivity of Magnesium Metaphosphate Glasses (MgO.$P_2O_5$ 유리의 전기전도도에 미치는 수분의 영향)

  • 강은태;박용완
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.4
    • /
    • pp.85-89
    • /
    • 1986
  • Electrical conductivity have been measured as function of temperature in MgO.$P_2O_5$ glasses containing small amounts of water. Conduction was due to the contribution of $H^+$ and the mobility of protons in the glass increased linearly with increasing its concentration. The conductivity was pro-portional to the square of the proton concentration and the activation energy decreased linerly with increasing logarithm of the proton concentration, And $$\sigma$_0$ and $A_0$ was independent of the proton concentration but not on glass compositions.

  • PDF

The Change of Blood Properties of HK Phenotype Jindo dogs Administrated with Excessive Amount of Water Celery Extracts (과량의 미나리 생즙 투여가 HK phenotype 진도견의 혈액상의 미치는 영향)

  • ;;;;;;;;Osamu Yamato
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.334-340
    • /
    • 2001
  • This study was conducted to investigate changes in blood properties of high potassium (HK) phenotype Jindo dogs (15kg$\pm$2kg) after daily oral administration with water celery extracts (10 ml/kg) for 7 days. Blood samples were collected for three days in a row before administration of water celery extracts. After water celery extracts administration, blood samples were collected at 3h, 6h, 9h and then on daily basis until day 10 post administration (PA). At day 15, final sample was collected. Blood samples were analyzed on the basis of red blood cell (RBC), white blood cell (WBC), packed cell volume (PCV), hemoglobin (Hb) concentration, mean corpuscular volume(MCV), mean corpuscular hemoglobin concentration(MCHC), gluthathione concentration(GSH) and met-hemoglobin(Met-Hb) concentration. The significant changes (p<0.01, p<0.05) of RBCs were shown at 3 h to day 5, and days 7 and 9 after administration. PCV values were decreased form 3 h to day 10 after administration. Mean Hb concentration showed significant increase as 3 h to day 3, and day 6 to day 9 after administration. The significant changes (p<0.05) of WBCs were shown at 9 h and day 1 after administration. The increased numbers of MCV were detected at days 6 to 9 after administration (p<0.05, p<0.01). The significant changes of MCHC were shown at 9h and day 1 after administration. The significant increases (p<0.01, p<0.05) of GSH concentration were detected at days 1, 6 and 7 after administration. In Met-Hb concentration, the significant increases (p<0.05) occurred at only 9h and day 7 after administration, The significant increases (p<0.01, p<0.05) of reticulocyte were detected at days 2, 4, 5, 6 and 7. Data from blood samples collected at day 15 after administration showed that all of blood analysis results returned to normal level, compared to controls.

  • PDF

The Systematic Management for Trace Hazard Compounds in Drinking Water (수돗물에서 미량유해물질의 체계적 관리방안 연구)

  • Park, Sun-Ku;Rim, Yeon-Taek
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.431-441
    • /
    • 2005
  • The study was carried out to improve and regulate the drinking water quality standard and drinking water quality monitoring substances. For the reliability and safety of finished water, It has been monitored for trace organic and inorganic compounds of 333 in finished water of water treatment plants during 1989 to 2003. As a result of monitoring, 51 compounds were detected from 333 compounds, and it has been regulated the drinking water quality standard of 26 substances and 20 mitoring substance. Improvement and regulation method of the drinking water quality standard was performed by comparing and analyzing with detection concentration, detection frequency, risk assessment and foreign drinking water quality standard.

Corrosivity Characteristics of Raw Water in Korea (국내 상수원수의 부식성 특성)

  • Kim, Jin-Keun;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.839-846
    • /
    • 2011
  • To investigate corrosivity characteristics of raw water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Annual average values of LI at 30 WTPs were all negative, which means raw water in Korea is very corrosive. LI results for 4 major rivers showed that raw water from Han and Nakdong had relatively high values compared to those of Sumjin and Keum. On the other hand, LI values of raw water from the tributaries of four major rivers were relatively low presumably due to geological characteristics, and in some cases the values were less than -4.0 which means increase of LI is urgently needed to minimize red water problem. Based on the correlation results among LI and water quality parameters, pH, water temperature, calcium concentration were confirmed as major components for LI. Therefore, pH and calcium concentration control is an effective method for the improvement of LI in water treatment processes.